Catalog excerpts
Clamp Meters Clamp Meters MD 9273 Bluetooth® TRMS Leakage Clamp with Power Functions The MD 9273 is the new Bluetooth-enabled expansion to the Metrel multifunctional testers MI 3155, MI 3152 and MI 3325. When used together, they form a team for measuring data from a safe distance. The multifunctional instruments can record inrush current from MD 9273 measurement and display data in table or graph form, or they can be used to generate a 128 Hz signal that MD 9273 can filter and follow for cable tracing. When acting as a remote probe, it can send data on current, voltage, power, and harmonics. On the other hand, it is an independent instrument with improved accuracy, construction, and new functions like VFD filter. It can accurately read the TRMS AC leakage current of a system, detect losses in the system, suggest possible reasons for the loss, sense the harmonics in the signal, and perform basic power quality tests. MEASUREMENT FUNCTIONS • TRMS AC and DC voltage measurement; • TRMS AC current measurement; • Frequency measurement; • VFD frequency and voltage measurement; • Harmonics measurement; • Power parameters measurement. KEY FUNCTIONS • Bluetooth connection to MI 3155, MI 3152 and MI 3325. • Inrush current recording with MI 3155, MI 3152 and MI 3325. • Online measurements of current, voltage, power, current harmonics, and voltage harmonics. • 128 Hz notch filter for cable tracing. • TRMS: accurate measurements on sinusoidal and non-sinusoidal signals. • Jaw size: 28 mm. • Shielded jaw: shielded jaw allows the clamp meter to be used in the noisiest environments. • Accurate: readings of AC current with an accuracy of 0.8 % and a base resolution of 0.01 mA and voltage with an accuracy of 0.5 % and a base resolution of 0.01 V. • Power: measures various power parameters (active, reactive, apparent power, THD, PF, phase displacement). • Intelligent loss analysis: complex algorithms detect loss and allow determining possible reasons for current loss. • Harmonics: measures current or voltage harmonic components and a percentage value of a harmonic up to the 19th. • THD and PF: dual display allows readings to be displayed along with Total Harmonic Distortion (THD) or Power Factor (PF). • Peak value: the peak value of the waveform or crest factor can be displayed. • MAX/MIN/HOLD mode: displays maximum, minimum or last measured value. APPLICATIONS • Basic power quality analysis. • Troubleshooting in installations. • Troubleshooting of devices and machines. • Electric vehicles troubl
Open the catalog to page 1TECHNICAL SPECIFICATION ORDERING INFORMATION Current Harmonics Voltage harmonics Crest factor voltage/current Peak value voltage Peak value current Power Supply Overvoltage category Standard set (MD 9273) • MD 9273 Bluetooth® TRMS Leakage Clamp with Power Functions • Test lead with probe, 2 pcs • AMD 9028 Alligator clip, 2 pcs • 1.5 V battery, type AA, 2 pcs • Pouch • Instruction manual • Calibration certificate OPTIONAL ACCESSORIES Photo Test lead with probe, 2 pcs Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery. Subject to technical...
Open the catalog to page 2All METREL catalogs and technical brochures
-
MI 3114 PV Tester
2 Pages
-
MI 3215 TeraOhmHP 15 kV
2 Pages
-
MI 3211 TeraOhmHP 10 kV
2 Pages
-
MI 3115 PV Analyser EN
2 Pages
-
MI 3132 EV Tester EN
3 Pages
-
MI 3365 25A OmegaEE XD EN
8 Pages
-
MI 3365 F OmegaEE XD EN
8 Pages
-
MI 3365 M OmegaEE XD EN
8 Pages
-
MI 3365 OmegaEE XD EN
8 Pages
-
MI 3360 OmegaGT XA guide EN
56 Pages
-
MD 9210 Mini Clamp Meter EN
2 Pages
-
Medical Facilities catalogue
64 Pages
-
Building Facilities catalogue
72 Pages
-
General catalogue 2023 EN
272 Pages
-
MI 3299 HV demo BOX
1 Pages
-
SW 1203 Metrel SDK EN
3 Pages
-
MI 3360 OmegaGT XA EN
4 Pages
-
MI 3325 MultiServicerXD EN
4 Pages
-
MI 3394 CE MultiTesterXS EN
2 Pages
-
MI 3394 CE MultiTesterXA EN
3 Pages
-
MI 6601 MediTest EN
4 Pages
-
MI 3110 EurotestIM EN
2 Pages
-
A 1722 PRCD adapter EN
2 Pages
-
A 1632 eMobility Analyser EN
2 Pages
-
A 1532 XA EVSE adapter EN
2 Pages
-
A 1532 EVSE adapter EN
2 Pages
-
MI 2093 Line Tracer EN
2 Pages
-
MI 3109 EurotestPV Lite EN
2 Pages
-
MI 3108 EurotestPV EN
2 Pages
-
MI 3125 BT EurotestCOMBO EN
2 Pages
-
MI 3125 EurotestCOMBO EN
2 Pages
-
MI 3100 SE EurotestEASI EN
2 Pages
-
MI 3102 BT EurotestXE EN
2 Pages
-
MI 3143 Euro Z 440 V EN
2 Pages
-
MI 3144 Euro Z 800 V EN
2 Pages
-
MI 3202 GigaOhm 5 kV EN
2 Pages
-
MI 3201 TeraOhm 5 kV Plus EN
2 Pages
-
MI 3311 GammaGT EN
2 Pages
-
MI 3309 BT DeltaGT EN
2 Pages
-
MI 3242 MicroOhm 2A EN
2 Pages
-
MI 3250 MicroOhm 10A EN
2 Pages
-
MI 3252 MicroOhm 100A EN
2 Pages
-
MI 3281 WR Analyser EN
2 Pages
-
MI 2891 Power Simulator EN
2 Pages
-
MI 2883 Energy Master EN
4 Pages
-
MI 2885 Master Q4 EN
4 Pages
-
MI 2884 Energy Master XA EN
4 Pages
-
MI 2892 Power Master EN
4 Pages
-
MI 2893 Power Master XT EN
4 Pages
-
MI 3205 TeraOhmXA 5kV EN
2 Pages
-
MI 3210 TeraOhm XA 10kV EN
2 Pages
-
Metrel application catalogue
28 Pages
-
MI 3155 EurotestXD EN
4 Pages
-
MI 3209 TeraOhmLT 10kV EN
2 Pages
-
MI 3102 BT EurotestXE
2 Pages
-
MD 9930 Thermal camera EN
2 Pages
-
MI 3280 DT Analyser EN
2 Pages
-
MI 3290 Earth Analyser EN
4 Pages
-
MI 3152 EurotestXC EN
2 Pages