Overview: The MD 9250 TRMS AC/DC CAT IV 1000V Clamp Meter is a high-quality instrument designed for single-hand operation, suitable for demanding industrial applications. It features a large jaw capacity for measuring AC/DC currents up to 2000 A and includes various measuring functions such as TRMS AC/DC, capacitance, temperature, and resistance.
Specifications: The clamp meter supports a wide range of measurements with high accuracy, including DC voltage (6.000 V to 1000 V), AC voltage (50 Hz to 400 Hz), DC current (200.0 A to 2000 A), and temperature (-50 °C to 1000 °C). It operates on two 1.5 V AAA batteries and is protected against overvoltage up to CAT IV / 1000 V.
Key Features: The MD 9250 includes features such as TRMS for accurate measurements, VFD for motor control signal measurement, high current measurement capability, AutoCheck® mode for low input impedance, transient protection, relative zero mode, PC link for data transfer, and in-rush current capture. It also has a backlight for working in dark conditions and a dual LCD display.
Applications: This clamp meter is ideal for testing solar and wind power systems, UPS systems, utility-scale battery systems, and high-level industrial and electrical testing.
Ordering Information: The standard set includes the MD 9250 clamp meter, test leads, a thermocouple probe, batteries, a carrying bag, an instruction manual, and a calibration certificate. Optional accessories include alligator clips, additional test leads, and a PC interface set.
See more

Catalog excerpts

MD 9250 Industrial TRMS AC/DC CAT IV 1000 V EN-1

Current clamp Clamp meters MD 9250 TRMS AC/DC CAT IV 1000V Clamp Meter The MD 9250 is the first Clamp Meter that meets overvoltage category CAT IV 1000 V. MD 9250 is a high quality clamp meter specially designed for single-hand operation, built-in measuring functions; TRMS AC/DC (current, voltage), capacitance, temperature and full range resistance makes this instrument an ideal tool for the most demanding applications in the industrial sector. The large jaws capacity of (max. 55 mm) in diameter allows AC/DC - current measurements up to 2000 A. High resolution and accuracy, 2-line LCD display fast data acquisition and transfer (via optical interface), non-contact voltage detection, and autocheck function are highlights of the instrument. MEASURING FUNCTIONS • TRMS AC, DC voltage measurement; • TRMS AC, DC current measurement; • Capacitance measurement; • Resistance measurement; • Diode test; • Frequency measurement; • Electric field detection; • Continuity test (acoustic signalling); • Temperature measurement. KEY FEATURES • Large jaws: for measuring on 55mm size conductors. • TRMS: accurate measurements on sinusoidal and non-sinusoidal signals. • VFD: correctly measure frequency and voltage of signals for motor control • High current: 2000 A DC & AC clamp on measurement. • Lo-Z: AutoCheck® mode provides low (rampup) input impedance to drain ghost voltages. • Auto-check function: automatic detection of AC voltage, DC voltage or resistance. • Auto-ranging: user can switch between auto and manual ranging. • Transient protection: it protects user in case of lightning strike or switching surge up to 12 kV. • Relative zero mode: relative function for comparing the difference between signals or removing background noise. • PC Link: test results can be downloaded to the computer via the optional PC software. • In-rush: fast 5ms Crest-MAX mode to capture in-rush currents. • Temperature: measures temperature in Celsius up to 1000 °C and in Fahrenheit up to 1832 °F. • Hold: data hold function freezes the display for later view. • Backlight: large bright 3-5/6 digits 6,000 counts + 1,999 counts dual LCD display with backlight for working in dark conditions. • Safe: CAT IV / 1000 V overvoltage protection. APPLICATION • Solar and wind power system testing; • UPS system testing; • Utility scale battery system testing; • High lev

 Open the catalog to page 1
MD 9250 Industrial TRMS AC/DC CAT IV 1000 V EN-2

TECHNICAL SPECIFICATION ORDERING INFORMATION Variable Frequency Drive from ±(4.0% of reading + 80 digits) to ±(7.0% of reading + 80 digits) from ±(2.0% of reading + 5 digits) to ±(2.5% of reading + 5 digits) from ±(2.0% of reading + 5 digits) to ±(3.5% of reading + 5 digits) Diode Test Open-circuit voltage < 1.8 V DC, Test current 0.56 mA Resistance & Autocheck from ±(0.5% of reading + 5 digits) to ±(2.3% of reading + 5 digits) from ±(2.0% of reading + 5 digits) to ±(4.0% of reading + 5 digits) Mains frequency Power supply Overvoltage category Standard set MD 9250 • MD 9250 TRMS AC/DC CAT IV...