Current clamp Clamp meters MD 9250 TRMS AC/DC CAT IV 1000V Clamp Meter The MD 9250 is the first Clamp Meter that meets overvoltage category CAT IV 1000 V. MD 9250 is a high quality clamp meter specially designed for single-hand operation, built-in measuring functions; TRMS AC/DC (current, voltage), capacitance, temperature and full range resistance makes this instrument an ideal tool for the most demanding applications in the industrial sector. The large jaws capacity of (max. 55 mm) in diameter allows AC/DC - current measurements up to 2000 A. High resolution and accuracy, 2-line LCD display fast data acquisition and transfer (via optical interface), non-contact voltage detection, and autocheck function are highlights of the instrument. MEASURING FUNCTIONS • TRMS AC, DC voltage measurement; • TRMS AC, DC current measurement; • Capacitance measurement; • Resistance measurement; • Diode test; • Frequency measurement; • Electric field detection; • Continuity test (acoustic signalling); • Temperature measurement. KEY FEATURES • Large jaws: for measuring on 55mm size conductors. • TRMS: accurate measurements on sinusoidal and non-sinusoidal signals. • VFD: correctly measure frequency and voltage of signals for motor control • High current: 2000 A DC & AC clamp on measurement. • Lo-Z: AutoCheck® mode provides low (rampup) input impedance to drain ghost voltages. • Auto-check function: automatic detection of AC voltage, DC voltage or resistance. • Auto-ranging: user can switch between auto and manual ranging. • Transient protection: it protects user in case of lightning strike or switching surge up to 12 kV. • Relative zero mode: relative function for comparing the difference between signals or removing background noise. • PC Link: test results can be downloaded to the computer via the optional PC software. • In-rush: fast 5ms Crest-MAX mode to capture in-rush currents. • Temperature: measures temperature in Celsius up to 1000 °C and in Fahrenheit up to 1832 °F. • Hold: data hold function freezes the display for later view. • Backlight: large bright 3-5/6 digits 6,000 counts + 1,999 counts dual LCD display with backlight for working in dark conditions. • Safe: CAT IV / 1000 V overvoltage protection. APPLICATION • Solar and wind power system testing; • UPS system testing; • Utility scale battery system testing; • High lev
Open the catalog to page 1TECHNICAL SPECIFICATION ORDERING INFORMATION Variable Frequency Drive from ±(4.0% of reading + 80 digits) to ±(7.0% of reading + 80 digits) from ±(2.0% of reading + 5 digits) to ±(2.5% of reading + 5 digits) from ±(2.0% of reading + 5 digits) to ±(3.5% of reading + 5 digits) Diode Test Open-circuit voltage < 1.8 V DC, Test current 0.56 mA Resistance & Autocheck from ±(0.5% of reading + 5 digits) to ±(2.3% of reading + 5 digits) from ±(2.0% of reading + 5 digits) to ±(4.0% of reading + 5 digits) Mains frequency Power supply Overvoltage category Standard set MD 9250 • MD 9250 TRMS AC/DC CAT...
Open the catalog to page 2All METREL catalogs and technical brochures
-
MI 3114 PV Tester
2 Pages
-
MI 3215 TeraOhmHP 15 kV
2 Pages
-
MI 3211 TeraOhmHP 10 kV
2 Pages
-
MI 3115 PV Analyser EN
2 Pages
-
MI 3132 EV Tester EN
3 Pages
-
MI 3365 25A OmegaEE XD EN
8 Pages
-
MI 3365 F OmegaEE XD EN
8 Pages
-
MI 3365 M OmegaEE XD EN
8 Pages
-
MI 3365 OmegaEE XD EN
8 Pages
-
MI 3360 OmegaGT XA guide EN
56 Pages
-
MD 9210 Mini Clamp Meter EN
2 Pages
-
Medical Facilities catalogue
64 Pages
-
Building Facilities catalogue
72 Pages
-
General catalogue 2023 EN
272 Pages
-
MI 3299 HV demo BOX
1 Pages
-
SW 1203 Metrel SDK EN
3 Pages
-
MI 3360 OmegaGT XA EN
4 Pages
-
MI 3325 MultiServicerXD EN
4 Pages
-
MI 3394 CE MultiTesterXS EN
2 Pages
-
MI 3394 CE MultiTesterXA EN
3 Pages
-
MI 6601 MediTest EN
4 Pages
-
MI 3110 EurotestIM EN
2 Pages
-
A 1722 PRCD adapter EN
2 Pages
-
A 1632 eMobility Analyser EN
2 Pages
-
A 1532 XA EVSE adapter EN
2 Pages
-
A 1532 EVSE adapter EN
2 Pages
-
MI 2093 Line Tracer EN
2 Pages
-
MI 3109 EurotestPV Lite EN
2 Pages
-
MI 3108 EurotestPV EN
2 Pages
-
MI 3125 BT EurotestCOMBO EN
2 Pages
-
MI 3125 EurotestCOMBO EN
2 Pages
-
MI 3100 SE EurotestEASI EN
2 Pages
-
MI 3102 BT EurotestXE EN
2 Pages
-
MI 3143 Euro Z 440 V EN
2 Pages
-
MI 3144 Euro Z 800 V EN
2 Pages
-
MI 3202 GigaOhm 5 kV EN
2 Pages
-
MI 3201 TeraOhm 5 kV Plus EN
2 Pages
-
MI 3311 GammaGT EN
2 Pages
-
MI 3309 BT DeltaGT EN
2 Pages
-
MI 3242 MicroOhm 2A EN
2 Pages
-
MI 3250 MicroOhm 10A EN
2 Pages
-
MI 3252 MicroOhm 100A EN
2 Pages
-
MI 3281 WR Analyser EN
2 Pages
-
MI 2891 Power Simulator EN
2 Pages
-
MI 2883 Energy Master EN
4 Pages
-
MI 2885 Master Q4 EN
4 Pages
-
MI 2884 Energy Master XA EN
4 Pages
-
MI 2892 Power Master EN
4 Pages
-
MI 2893 Power Master XT EN
4 Pages
-
MI 3205 TeraOhmXA 5kV EN
2 Pages
-
MI 3210 TeraOhm XA 10kV EN
2 Pages
-
Metrel application catalogue
28 Pages
-
MI 3155 EurotestXD EN
4 Pages
-
MI 3209 TeraOhmLT 10kV EN
2 Pages
-
MI 3102 BT EurotestXE
2 Pages
-
MD 9930 Thermal camera EN
2 Pages
-
MI 3280 DT Analyser EN
2 Pages
-
MI 3290 Earth Analyser EN
4 Pages
-
MI 3152 EurotestXC EN
2 Pages