Application Note MD line for EV service Electric vehicles have a new spectre of needs when it comes to servicing. Electrical faults, while essentially rare, can cause serious hazards to both the user and the service personnel. Electrical effects like electrolysis on material contact or battery leakage have to be considered during design. Regulation for electric cars is currently still weak. The UN regulation UNECE R100 prescribes safety features for the battery, most of which have to be tested by the manufacturer. After the battery is installed, internal systems in the car monitor its status. Few car models allow any kind of electrical testing and consider the on-board monitoring enough. Some tests should still be done in case of a suspected failure. MD 9070's main strengths are insulation measurement with up to 1000 VDC test voltage, and continuity test with 200 mA test current. It measures TRMS voltage up to 1000 V AC or DC, frequency with or without a VFD filter, resistance, diode test, and tests for continuity with audible signal. It allows for a number of diagnostic and safety tests in cars or elsewhere. • Testing battery pack’s nominal voltage with the voltmeter, • Faults on PCBs with audible continuity, resistance measurement and voltmeter, • Controlling signals on electric motors with VFD filtered frequency, • Testing insulation between any live and any accessible parts while live parts are off, • Testing continuity of wires, • lectric motor start-up test E with MAX/MIN/AVG recorder and a current clamp. MD 9272 is an AC clamp with lowest range down to 0.1 μA. It makes it a great tool for leakage analysis. In an EV, leakage is a powerful diagnostic tool at every point in its operation, from charging to driving. Its power functions and harmonic analysis offer additional layers of service. It can perform some functional tests on the inverters and motors, and particularly assure the inverters cause no
Open the catalog to page 1MD 9273 is the upgrade on the MD 9272. It contains all the features in MD 9272 and a number of extras, the main of which is Bluetooth connection to MI 3155 and work in tandem. It can trace inrush current and the application on MI 3155 will draw a graph. On the other hand, MI 3155 can generate a signal into the wiring system that can be traces with MD 9273. Bluetooth also enables easy upgrades of the firmware and the features list will eventually grow. Optional accessories provided by Metrel that are necessary for some of the mentioned measurements are the A 1734 reference resistance R0, and...
Open the catalog to page 2Testing insulation on the battery system Battery system is in the UN ECE R100 referred to as Rechargeable energy storage system or RESS. MD 9070 makes its name as basic installation tester also with testing for continuity. Continuity with 200 mA measuring current is mainly used to test the car’s PE wire from any higher-voltage device to the chassis. The car is not grounded as in actually connected to the ground, and the chassis is used as voltage reference. That makes it an IT system, and insulation is the more important safety parameter. 200 mA is a standard test current for 230 V...
Open the catalog to page 3Measuring motor controller with VFD frequency filter MD 9070 is equipped with a low pass filter for debugging VFD type of drives. VFD is a mainly industrial motor controller. It creates a pulse-width modulated signal to precisely control motor’s speed and torque. Motors equipped with it are amongst most energy efficient for variable-torque applications. It is not very common in the cars, but can be found in some models. The pulse-modulated signal is very rich in high-frequency components, making it impossible for the regular multimeter to measure its base frequency and voltage correctly....
Open the catalog to page 4Modern types are electronic and generally shouldn’t cause too much trouble, but faults or bad design can cause overheating and damage other parts of the installation or even the batteries. The system has to be tested for leakage, power parameters and distortion. Leakage is measured by turning the rotary switch to Ampere symbol and clamping the relevant wires. Usually, that is the PE for direct measurement, or both live and neutral wires for the differential measurement. Functional testing and harmonics Functional test is device-specific and often cannot be done using a measuring device....
Open the catalog to page 5All METREL catalogs and technical brochures
-
MI 3114 PV Tester
2 Pages
-
MI 3215 TeraOhmHP 15 kV
2 Pages
-
MI 3211 TeraOhmHP 10 kV
2 Pages
-
MI 3115 PV Analyser EN
2 Pages
-
MI 3132 EV Tester EN
3 Pages
-
MI 3365 25A OmegaEE XD EN
8 Pages
-
MI 3365 F OmegaEE XD EN
8 Pages
-
MI 3365 M OmegaEE XD EN
8 Pages
-
MI 3365 OmegaEE XD EN
8 Pages
-
MI 3360 OmegaGT XA guide EN
56 Pages
-
MD 9210 Mini Clamp Meter EN
2 Pages
-
Medical Facilities catalogue
64 Pages
-
Building Facilities catalogue
72 Pages
-
General catalogue 2023 EN
272 Pages
-
MI 3299 HV demo BOX
1 Pages
-
SW 1203 Metrel SDK EN
3 Pages
-
MI 3360 OmegaGT XA EN
4 Pages
-
MI 3325 MultiServicerXD EN
4 Pages
-
MI 3394 CE MultiTesterXS EN
2 Pages
-
MI 3394 CE MultiTesterXA EN
3 Pages
-
MI 6601 MediTest EN
4 Pages
-
MI 3110 EurotestIM EN
2 Pages
-
A 1722 PRCD adapter EN
2 Pages
-
A 1632 eMobility Analyser EN
2 Pages
-
A 1532 XA EVSE adapter EN
2 Pages
-
A 1532 EVSE adapter EN
2 Pages
-
MI 2093 Line Tracer EN
2 Pages
-
MI 3109 EurotestPV Lite EN
2 Pages
-
MI 3108 EurotestPV EN
2 Pages
-
MI 3125 BT EurotestCOMBO EN
2 Pages
-
MI 3125 EurotestCOMBO EN
2 Pages
-
MI 3100 SE EurotestEASI EN
2 Pages
-
MI 3102 BT EurotestXE EN
2 Pages
-
MI 3143 Euro Z 440 V EN
2 Pages
-
MI 3144 Euro Z 800 V EN
2 Pages
-
MI 3202 GigaOhm 5 kV EN
2 Pages
-
MI 3201 TeraOhm 5 kV Plus EN
2 Pages
-
MI 3311 GammaGT EN
2 Pages
-
MI 3309 BT DeltaGT EN
2 Pages
-
MI 3242 MicroOhm 2A EN
2 Pages
-
MI 3250 MicroOhm 10A EN
2 Pages
-
MI 3252 MicroOhm 100A EN
2 Pages
-
MI 3281 WR Analyser EN
2 Pages
-
MI 2891 Power Simulator EN
2 Pages
-
MI 2883 Energy Master EN
4 Pages
-
MI 2885 Master Q4 EN
4 Pages
-
MI 2884 Energy Master XA EN
4 Pages
-
MI 2892 Power Master EN
4 Pages
-
MI 2893 Power Master XT EN
4 Pages
-
MI 3205 TeraOhmXA 5kV EN
2 Pages
-
MI 3210 TeraOhm XA 10kV EN
2 Pages
-
Metrel application catalogue
28 Pages
-
MI 3155 EurotestXD EN
4 Pages
-
MI 3209 TeraOhmLT 10kV EN
2 Pages
-
MI 3102 BT EurotestXE
2 Pages
-
MD 9930 Thermal camera EN
2 Pages
-
MI 3280 DT Analyser EN
2 Pages
-
MI 3290 Earth Analyser EN
4 Pages
-
MI 3152 EurotestXC EN
2 Pages