TE30

TE30

TE30

Product catalog summary
Introduction
The TE30 Analyser and Tester is designed for verifying power network wiring, calibrating and testing electricity meters and instrument transformers, and analyzing power quality. It features a large touchscreen for easy operation and displays measurement results in various formats such as tables, vectors, and charts.

Specifications
The device measures power network parameters including voltages, currents, frequency, phase angles, power factors, and powers. It supports voltage ranges from 0.05 to 600V and 0.1 to 40kV, and current ranges from 0.001 to 1200A. The analyser operates with a power supply of 50 to 450V AC and has an internal battery.

Testing Capabilities
The TE30 can test electricity meters on-site, calculating meter errors and measuring energy. It also tests instrument transformers, calculating transformer ratio and phase errors. The device supports burden measurements for CT and PT transformers.

Power Quality Analysis
The analyser measures power quality parameters according to IEC 61000-4-30 class A and records data in SD flash memory. It can analyze results for EN 50160 compatibility.

Data Handling
Data can be read and controlled via USB, Ethernet, and Bluetooth, with storage capabilities up to 32GB on an SD card.

General Parameters
The device weighs 2kg and measures 270x245x90mm. It operates within a temperature range of -10 to +50°C and has a degree of protection rated at IP-40.

Performance and Accuracy
The TE30 offers high accuracy with error limits specified for various parameters, ensuring reliable measurements for professional use.
See more

Catalog excerpts

TE30-1

NETWORK ANALYSER HIGHLIGHTS: □ Measure of power network parameters in class 0.05 or 0.1 □ Voltage ranges 0.05...600V and 0.1...40KV □ Current ranges 0.001...12(120)(1200)(30/300/3000)A □ Testing of electricity meters and CT/PT Transformers □ Recording and analyze of power quality □ Vector, oscilloscope, bar and trend charts of three phase network □ Powering from 50.450V AC power network and internal battery with charger □ Large 7" color Touchscreen □ Data readout and meter control via USB, Ethernet and Bluetooth □ Data storage in SD flash memory card up to 32GB INTRODUCTION The TE30 Analyser and Tester is used for: • verification of power network wiring with measure and recording of power network parameters, • calibration and testing of electricity meters and instrument transformers (CT Current Transformers and PT Potential Transformers) directly on site • measuring, recording and analyzing of power quality. Large Touchscreen with display and keyboard functions for easy operation enables: • measure of power network parameters: voltages U1, U2, U3, U12, U23, U31, UN; currents I1, I2, I3, IN; frequency; phase angles tpl, (p2, (p3; power factors PF1, PF2, PF3, IPF; factors sinpl, sinp2, sinp3, Isinp, tgpl, tgp2, tgp3, Itgp; angles between voltages U12, U23, U31; powers P1, P2, P3, IP, Q1, Q2, Q3, IQ, S1, S2, S3, IS • visualization of measurement results in form of table, vectors, trend chart, oscilloscope (waveform) or bar chart (harmonics of U, I, P, Q). Testing of electricity meters directly on site: • function of calculating meter error (partial errors, average error, standard deviation) directly in [%] with method of settings time of measurements or number of impulses, • function of automatic identification meter constant, • function of automatic determining measurement time or number of pulses, • function of measuring energy with method of setting time for verification of meter counters directly in [%], • function of maximum power measuring for testing of maximum power meters, • visualization in form of table or trend chart, • function of measuring energy for power P, P+, P-, Q, Q+, Q-, S, • function of measuring energy for the first harmonic of active power PH1. Testing of instrument transformers (LV and MV current CT and potential PT simultaneously in three phases) directly on site: • functions of calculating transformer ratio error directly in [%], • functions of calculating phase error, • functions of burden measurements of transformer. Power quality analyser function enables: • measuring of power quality parameters according to IEC 61000-4-30 class A with visualization of measurement results in the real time mode, • recording of power network parameters i n the SD Flash 432GB memory, which gives (8..64)x106 sets of network parameters or long-term registration of power quality (option), • analyzing of measurement results for EN 50160 compatibility or individual requirements of user (option). METERTEST

 Open the catalog to page 1
TE30-2

POWER NETWORK ANALYZER (1) % - related to the measuring value, %* - related to the measuring range final value (is underlined) (2) error limits include reference standard uncertainty, 12 mo. stability, influence quantities (ambient temp. +20...+26°C, humidity, power supply 50...450V, freq. 45...65Hz) (5) Em - sensor basic error, Em=1 %+0.1 %* (Flexible Clamps FCT5000AC), Em=2%+0.2%* (VoltLiteWire 40kV and AmpLiteWire 2000A) (4) power and energy errors related to apparent power (5) in voltage range 10...600V (Direct) (6) in current range 0.01 ...12A (Direct) (7) in current range: 0.1A...12A (Clamps...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.