Catalog excerpts
ILF G2 | ILF G2 Pro _Low Voltage Live Network phase and feeder identifier It results critical to know the network topology data in order to maintain a correct management of electrical distribution networks. Therefore, it's essential to know HOW and WHERE each of the LV assets/consumers are connected, to which transformer-feeder-phase. The use of this information in a GIS solution allows calculation of transformer load balances, faults, preventive maintenance task planning, etc., and at end, guarantees the quality of electrical supply. Merytronic has designed the new generation of Phase and Feeder identifiers ILF G2 and ILF G2 Pro, which can identify 3 phases and up to 12 feeders of a transformer output. They are designed for big mapping campaigns, up to 99 Transformer Substations simultaneously. Thanks to its app GridGIS Connect (develop by ARIADNA Grid) speeds up collection, storage and transfer data to utility's GIS system. The network topology digitalization campaigns result shorter and the integration of topology data into utility's GIS system faster and without mistakes. Main features: ■ Works in service, without de-energizing the network ■ Identify to which of the three phases and up to 12 feeders the consumers are connected ■ Designed for big mapping campaigns ■ Identification is done a few seconds ■ Up to 99 Transformer Substation simultaneously ■ Proved efficiency on cable distances > 1 km. ■ Suitable for any Low Voltage Network configurations: Delta, Star (no neutral), coupled and/or ringed networks, cascade arrangement, up to 480 Vac between Ph-Ph and 50 or 60 Hz. ■ ILF G2 Pro available for cascade arrangement of distribution networks (with several feeder pillars up to 4 electrical levels) ■ A single operator can easily use it. ■ Line Device with integrated Bluetooth ■ GridGIS Connect app for collect, storage and transfer data (compatible with GIS system). Q ■ Multiple field-work crews for each Transformer Substation (Central Device)
Open the catalog to page 1Size (mm) Protection Weight V Phase-Phase V Phase-Neutral Vmax connection Frequency Imax S.C. protection (1) Operating temperature Bluetooth frequency band operation Bluetooth output power (1) Short Circuit Protection Size (mm) Protection Weight V Phase-Neutral Vmax Power supply Frequency S.C. protection (1) Operating temperature Bluetooth frequency band operation Bluetooth output power Safety standards: IEC 61010-1:2010/EN 61010-1:2010/ UNE-EN 61010-1:2011; IEC 61010-2-030:2010/ UNE-EN 61010-2-030:2011; IEC 60950-1:2005 / EN 60950-2006 / UNE-EN 60950-1:2007. EMC standards: IEC...
Open the catalog to page 2All Merytronic catalogs and technical brochures
-
Geneal information portable
22 Pages
-
METRONIC -PORTABLE SOLUTION
1 Pages
-
GENERAL PRODUCT CATALOGUE
2 Pages