1. Catalogs
  2. Merytronic
  3. ARIADNA IF3: Low Voltage Phase Identifier

ARIADNA IF3: Low Voltage Phase Identifier

ARIADNA IF3: Low Voltage Phase Identifier

ARIADNA IF3: Low Voltage Phase Identifier

Product catalog summary
Overview: The document discusses the importance of updated low voltage connectivity data for managing electrical distribution networks effectively. It highlights the role of GIS solutions in improving electric supply quality by calculating transformer load balances and identifying critical network spots.
Main Features:
  • Operates on service networks without de-energizing the line.
  • Identifies three phases in seconds.
  • Communication between Central Device and Line Device occurs through coded messages via the distribution network, eliminating the need for additional communication equipment.
  • Usable by a single operator.
  • Compatible with all Low Voltage network configurations up to 440 V between phases, 50 or 60 Hz.
Ariadna IF3 Phase Identifier: Designed to meet electric utility needs, the Ariadna IF3 identifies connectivity data between subscribers and phases of an MV/LV transformer substation efficiently and reliably without interrupting electrical supply.
Technical Features:
  • Central Device (CD): Dimensions: 27.3x24.7x12.7 cm, Protection: IP65, Weight: 2.5 kg, Voltage: 200-480 Vac (50/60Hz), Short circuit protection: 2A fuses, Operating temperature: -10 ºC to 55 ºC.
  • Line Device (LD): Dimensions: 12x22x6.5 cm, Protection: IP54, Weight: 0.75 kg, Power supply: 4 x 1.5v AA batteries, Voltage: 100-290 Vac (50/60Hz), Short circuit protection: 6A fuse, Operating temperature: -10 ºC to 55 ºC.
Compliance: The Ariadna IF3 meets the European Low Voltage Directive 73/23/CEE. The Central Device complies with EN-50178, and the Line Device complies with EN 61010-1 standards.
See more

Catalog excerpts

ARIADNA IF3: Low Voltage Phase Identifier-1

Ariadna IF3Live network LV phase identifier The updated knowledge of low voltage connectivity data (link between MV/LV transformer and phase with end user) results critical for the correct management of electrical distribution network. With updated connectivity information a GIS solution may calculate transformer load balances, find critical network spots before any incident occurs, prepare maintenance task planning, ... i.e., improves electric supply quality. In order to cope with electric utility needs, Ariadna Instruments has designed the IF-3 Low Voltage phase identifier. This equipment determines the connectivity data between subscribers and phase of an MV/LV transformer substation in a fast, easy and reliable way. Ariadna IF3 works without deenergizing the line, so electrical supply is kept throughout the identification process. Main features: ■ Works in service networks, without de-energizing the line. ■ Three phases can be identified in few seconds. ■ Central Device and Line Device communicate with each other by means of coded messages through the distribution network. This way the use of radio or other communication extra equipment is avoided. ■ A single operator can easily use it. ■ Operational for all kind of Low Voltage network configurations, up to 440 V between phases, 50 or 60 Hz.

 Open the catalog to page 1
ARIADNA IF3: Low Voltage Phase Identifier-2

Working diagram Ariadna IF3 phase identifier meets European Low Voltage Directive 73/23/CEE and is compliant with: Central Device (CD): EN-50178, Electronic Equipment for use in power installations. Line Device (LD): EN 61010-1 (Safety requirements for Electrical Equipment for measurement, control and laboratory use). Technical features Dimensions (cm): Protection: Weight: V Phase-Phase V Phase-Neutral Vmax ( Phase-Neutral / Phase-Phase) Cable length: Dimensions (cm): Protection: Weight: Power supply: V working Vmax Cable length: Short circuit protection: Working temperature: 2A fuses 5x20mm...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.