Specifications:
The Bronze Y Strainer is available in sizes ranging from DN 3/8" to DN 4" with female BSP ends. It operates within a temperature range of -10°C to +120°C and can withstand a maximum pressure of 16 bars up to DN 2". The strainer features a removable stainless steel filter and is suitable for both horizontal and vertical installations with descending fluid flow.

Materials:
The body is made of bronze, the filter is stainless steel (SS 304), the gasket is a mix of PTFE and bronze, and the cap is brass.

Usage:
Designed for water distribution and watering applications, the strainer is effective within the specified temperature and pressure limits.

Range:
The strainer is available in threaded female BSP cylindrical forms for different references, with specific mesh sizes for types 202, 203, and 210.

Standards:
Manufactured according to ISO 9001:2008, the product complies with various water agreements and is excluded from the DIRECTIVE 97/23/CE.

Installation Instructions:
Ensure compatibility with installation conditions, maintain alignment of connecting pipes, and avoid using a vice for tightening. Regular testing of circuits is advised, and care should be taken to prevent solid objects from entering the strainer.

Advice:
The manufacturer advises verifying product suitability for specific service conditions, as they are not liable for damages resulting from improper use.
See more

Catalog excerpts

Strainer-Y.type-Threaded-Bronze-1

Size : Ends : Min Temperature : Max Temperature : Max Pressure : Specifications : DN 3/8" to 4" Female BSP - 10°C + 120°C 16 Bars up to DN 2“ Removable stainless steel filter Female / Female Materials : Bronze body Page 1 - 7 Information provided as an indication and subject to possible modification

 Open the catalog to page 1
Strainer-Y.type-Threaded-Bronze-2

MXT-1014-202-203-210 BRONZE Y STRAINER SPECIFICATIONS : Removable stainless steel filter Female / female type Horizontal or vertical position with descendant fluid (respect the flow direction indicated by the arrow ) For 202 type, Mesh 4/10° mm ( 400 µ ) up to DN 1“ and 5/10° mm ( 500 µ ) over For 203 and 210 types, Mesh 3/10° mm ( 300 µ ) With drainer threaded female BSP with butterfly aluminium handle for 210 type Water distribution and watering Min Temperature Ts : - 10°C Max Temperature Ts :+ 120°C Max Pressure PN : 16 bars up to DN 2“ , 10 bars over HEAD LOSS GRAPH : Page 2 - 7 Information...

 Open the catalog to page 2
Strainer-Y.type-Threaded-Bronze-3

MXT-1014-202-203-210 BRONZE Y STRAINER RANGE : Strainer threaded female BSP cylindrical from DN 3/8“ to DN 4“ for Ref. 202 et 203 Strainer with drain threaded female BSP cylindrical from DN 1/2“ to DN 2“ for Ref. 210 Page 3 - 7 Information provided as an indication and subject to possible modification

 Open the catalog to page 3
Strainer-Y.type-Threaded-Bronze-4

MXT-1014-202-203-210 BRONZE Y STRAINER SIZE TYPES 202 AND 203 ( in mm ) : Filter size : Page 4 - 7 Information provided as an indication and subject to possible modification

 Open the catalog to page 4
Strainer-Y.type-Threaded-Bronze-5

MXT-1014-202-203-210 BRONZE Y STRAINER SIZE TYPE 210 ( in mm ) : Filter size : Page 5 - 7 Information provided as an indication and subject to possible modification

 Open the catalog to page 5
Strainer-Y.type-Threaded-Bronze-6

MXT-1014-202-203-210 BRONZE Y STRAINER STANDARDS : DIRECTIVE 97/23/CE : Products excluded from directive ( Article 1, § 3.2 ) French water agreement A.C.S. N° 09 ACC LY 157 English water agreement WRAS Threaded female BSP cylindrical ends according to ISO 228/1 INSTALLATION POSITIONS : Vertical position ( descendand fluid ) Horizontal position ADVICE : Our opinion and our advice are not guaranteed and MXT shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 6 - 7 Information provided as an indication...

 Open the catalog to page 6
Strainer-Y.type-Threaded-Bronze-7

INSTALLATION INSTRUCTIONS GENERAL GUIDELINES : Ensure that the strainers to be used are appropriate for the conditions of the installation (type of fluid,pressure and temperature). Be sure to have enough valves to be able to isolate the sections of piping as well as the appropriate equipment for maintenance and repair. Ensure that the strainers to be installed are of correct strenght to be able to support the capacity of their usage. Installation of all circuits should ensure that their function can be automatically tested on a regular basis (at least two times a year). INSTALLATION INSTRUCTIONS...

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.