Check-Valve-Swing-Thread
5Pages

{{requestButtons}}

Catalog excerpts

Check-Valve-Swing-Thread - 1

MXT-3257-320 STAINLESS STEEL SWING CHECK VALVE PN16 Size : Ends : Min Temperature : Max Temperature : Max Pressure : Specifications : DN 1/4" to 2" Female BSP - 20°C + 200°C 16 Bars Swing type Metal / metal thickness Weak head loss Materials : Stainless steel Page 1 - 5 Information provided as an indication and subject to possible modification

Open the catalog to page 1
Check-Valve-Swing-Thread - 2

MXT-3257-320 STAINLESS STEEL SWING CHECK VALVE PN16 SPECIFICATIONS : Vertical position with ascendant fluid or horizontal position Respect the flow direction indicated by the arrow Female cylindrical threaded BSP ends Swing type Metal / metal thickness Chemical and pharmaceutical industries, petrochemical industries, hydraulic installation Min Temperature Ts : - 20°C Max Temperature Ts :+ 200°C Max Pressure PN : 16 bars Female cylindrical threaded BSP ends from DN 1/4“ to DN 2“ Stem gasket Bonnet gasket Page 2 - 5 Information provided as an indication and subject to possible modification

Open the catalog to page 2
Check-Valve-Swing-Thread - 3

MXT-3257-320 STAINLESS STEEL SWING CHECK VALVE PN16 SIZE ( in mm ) : Page 3 - 5 Information provided as an indication and subject to possible modification

Open the catalog to page 3
Check-Valve-Swing-Thread - 4

MXT-3257-320 STAINLESS STEEL SWING CHECK VALVE PN16 STANDARDS : DIRECTIVE 97/23/CE : Risk Category I Module A Threaded cylindrical female BSP ends according to ISO 228-1 INSTALLATION POSITIONS : Vertical position ( ascendant fluid ) Horizontal position ADVICE : Our opinion and our advice are not guaranteed and MXT shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 4 - 5 Information provided as an indication and subject to possible modification

Open the catalog to page 4
Check-Valve-Swing-Thread - 5

MXT-3257-320 STAINLESS STEEL SWING CHECK VALVE PN16 INSTALLATION INSTRUCTIONS GENERAL GUIDELINES : Ensure that the check valves to be used are appropriate for the conditions of the installation (type of fluid,pressure and temperature). Be sure to have enough valves to be able to isolate the sections of piping as well as the appropriate equipment for maintenance and repair. Ensure that the valves to be installed are of correct strenght to be able to support the capacity of their usage. INSTALLATION INSTRUCTIONS : Before installing the check valves, clean and remove any objects from the pipes...

Open the catalog to page 5

All MerxTrade BV catalogs and technical brochures

  1. MXT-13950000