Overview: The document details the specifications and features of Mersen's FA range of 750VDC on-board disconnector switches, designed for heavy-duty and railway applications. These disconnectors are known for their robustness, high performance, and minimal maintenance requirements.
Specifications: The disconnectors are available in a range of 250 to 2000 Amps, with a rated peak current of 50 kA and a voltage drop of 10 mV. They are designed for indoor use and can operate in temperatures ranging from -40°C to +70°C. The devices can be configured with 1 to 6 poles, offering flexibility in current ratings.
Features & Benefits: The disconnectors offer no-load operation and can be configured as disconnectors, change-overs, or earthing devices. They support manual or motorized operation and can include a locking system for enhanced security. The devices are designed to withstand harsh environments, including salty atmospheres, and feature self-cleaning blade contacts.
Applications: These disconnectors are suitable for main traction circuits, power control, and isolation of power converters and traction motors in rolling stock applications such as trains, trams, and metros.
Standards: The disconnectors comply with IEC 60077-1, IEC 60077-2, IEC 61373, and EN 50124 standards, ensuring reliability and safety in their applications.
Technical Data: The disconnectors have a mechanical endurance of at least 25,000 cycles. They can be customized with various features such as phase-to-phase distance adaptation, signaling, terminal boxes, and locking systems.
Accessories: The document lists various accessories, including copper grease, microswitches, mechanical operation counters, and manual operation handles. These accessories enhance the functionality and ease of maintenance of the disconnectors.
Additional Features: The disconnectors can be equipped with quick-acting systems, connection plate adaptations, and customized signaling options. They also support various motor voltage ratings and can be secured with blocking magnets for remote control operations.
Support & Services: Mersen offers technical support, training sessions, and studies on Life Cycle Costs (LCC), Reliability Availability Maintainability Safety (RAMS), and Failure Mode and Effect Analysis (FMEA). They also conduct qualification type tests to ensure product reliability.
See more

Catalog excerpts

Disconnectors FA range 750VDC 250 to 2000Amp-1

Disconnectors FA range 750VDC 250 to 2000Amp ON BOARD DISCONNECTOR SWITCH 750VDC ON BOARD DISCONNECTORS SWITCH FEATURES & BENEFITS • No Load operation • Indoor Type equipment • This technology offer various configurations - Disconnector or Change-over or Earthing - 1 to 4 different positions - up to 6 poles offering different ratings • Mersen offers one of the largest product ranges on the market for On-Board applications under 85VDC, 750VDC, 1.500VDC, 3.000VDC and 25kVAC. Mersen has a switch solution that will meet your unique needs. Our standard On-Board FA disconnector range is rigorously engineered to meet your technical specifications in different configurations (Disconnector, Change-over or Earthing) which can be installed in vertical or horizontal position. These devices offers High short-circuit currents withstand and Visible break by direct seeing of the mobile silver-plated copper contacts moreover a large isolation air and creepage distance Operation is easy and flexible: They can be operated manually or with an adapted motor (see list) and easily connected to the circuit using Copper busbar by bolting and self-supporting also they offer Self-cleaning blade contacts, ideal for polluted environments. This range can be studied and customised with Phase to Phase distance adaptation, Signalling, Terminal Box or Locking system functions. Indoor use in a current less state The Mechanical endurance is 25.000 cycles minimum warrantied for a device maintained according to the maintenance recommendations. APPLICATIONS • Main Traction circuit Change over (dual voltage) or isolation of Power Converter and traction motors • Power control with the possible functions to disconnect, to change-over or to earth the power source of rolling stock applications (Train, Tramway, Metro) MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet. For more than 100 years, Mersen have been providing the market with safe, reliable and longer life time off-load disconnectors and change-overs. These devices offer high performances and robustness for heavy duty and railway requirements with very limited maintenance. - Quick acting operation - manual or motorized operation - with or without locking system On Board Disconnector Switch / DS-PTRV-FA-750VDC-05-0219_EN

 Open the catalog to page 1
Disconnectors FA range 750VDC 250 to 2000Amp-2

TECHNICAL DATA OVERVIEW On Board Disconnectors FA 250 to 2000 Amp for DC under 750VDC Speed/Characteristic Around 5 seconds with motor operation (depend on configuration) Working Temperature -40°C to +70°C 1 to 6 poles with same or different current ratings (for more poles Number of Poles please consult) Size per Standard PRODUCT RANGE On-board FA 750VDC Catalog number Rated peak current RMS 20 ms short-time withstand current Voltage drop DIMENSIONS FA 750VDC Disconnector : 5 POLES - 3 POSITIONS 1-0 (Open - Closed) MANUAL OPERATION WITH FRONT PANEL dwg 1035699 MERSEN reserves the right to change,...

 Open the catalog to page 2
Disconnectors FA range 750VDC 250 to 2000Amp-3

Disconnectors FA range 750VDC 250 to 2000Amp DIMENSIONS FA 750VDC Disconnector : 3 POLES - 2 POSITIONS 1-0 (Open - Closed) with Quick Acting Spring System Manual Dwg 1019401 FA 750VDC Disconnector : 1 POLE - 3 POSITIONS 1-0-2 (Circuit1 - Open - Circuit2) Motorized operation MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet. On Board Disconnector Switch / DS-PTRV-FA-750VDC-05-0219_EN

 Open the catalog to page 3
Disconnectors FA range 750VDC 250 to 2000Amp-4

Disconnectors FA range 750VDC 250 to 2000Amp DIMENSIONS FA 750VDC Change_over : 1 POLE - 3 POSITIONS 1-3-2 (circuit 1 - Circuit 2 - Circuit 3) Manual Operation FA 750VDC Change_over : 1 POLE - 2 POSITIONS 1-2 (circuit 1 - Circuit 2) Manual Operation dwg 1042606 MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet. On Board Disconnector Switch / DS-PTRV-FA-750VDC-05-0219_EN

 Open the catalog to page 4
Disconnectors FA range 750VDC 250 to 2000Amp-5

Disconnectors FA range 750VDC 250 to 2000Amp MOTORS Motor types Motor voltage rating FUNCTIONS Salty / Laden atmosphere All the FA Disconnector range can withstand 96h00 (inside and outside) under salty atmosphere (more time withstand under request). Quick Acting pole- Tumbler The disconnectors can be equipped with quick acting system named tumbler based on spring compression. Connection plate adaptation To adapt the disconnector connexion to the Busbar or cables. Customized signaling This range can be equipped with micro switches offering 10 Amp under 400VAC (or AC15 230VAC 1Amp; DC13 110VDC...

 Open the catalog to page 5
Disconnectors FA range 750VDC 250 to 2000Amp-6

Disconnectors FA range 750VDC 250 to 2000Amp FUNCTIONS Manual Operation locking The Manual Operation disconnectors can have their position secured in Open or in Closed positions using padlocking systems (3 x diam 10mm) for complete security while maintenance operations. Motorized Operation Blocking magnets Blocking magnets are used to guarantee electromechanically the position of the Disconnector using remote control. This operation can be done for one or both position (open and closed). Blocking magnet can be used missing Voltage or Voltage can be 24VDC, 48VDC, 110VDC, 230VDC and 230VAC (consumption...

 Open the catalog to page 6
Disconnectors FA range 750VDC 250 to 2000Amp-7

Colour Mersen can paint the metal Front Panel and Cubicles to the color specified, as per the RAL chart, under your special painting process for protection and cosmetic reasons. Training and technical support All around the world, Mersen technical team can help you for technical support and can offer you customized training sessions for your Maintenance team. LCC; RAMS; Type tests ACCESSORIES Indication facilities Catalog number Item number Length MECHANICAL OPERATION COUNTER W110902 Microswitches Catalog number Item number Package Microswitches ON BOARD AUXILARY SWITCH (NO+NC) C1037578 Lubricants...

 Open the catalog to page 7
Disconnectors FA range 750VDC 250 to 2000Amp-8

Disconnectors FA range 750VDC 250 to 2000Amp ACCESSORIES Removable handles for emergency manual operation Catalog number Item number Length ARB FLEX SSB-7 1043 LIMITING TORQUE MAN D10 L170 S/E MANIVELLE D10.2 170 S/E MANIVELLE D10.2 170 Tropical S/E MANIVELLE D10.2 300 S/E MANIVELLE D10.2 480 S/E MANIVELLE D10.2 600 S/E MANIVELLE D10.2 1000 S/E SGN CDE SECOURS FLEX 1043 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece Manual operation handles Catalog number Item number Length ON BOARD MANUAL HANDLE G1042090 MERSEN reserves the right to change, update or correct, without...