Product catalog summary
Overview: Mersen is a leader in circuit protection, providing solutions for low voltage installations. Their products are ISO 9001 compliant, adhere to the RoHS Directive, and most are ASTA 20 certified.
Product Range: The document details BS88 LV Fuse Links and Fuse Holders, including Offset Bolted Tag Fuse Links (A-type), Offset Blade Fuse Links (F-type), and Central Bolted Tag Fuse Links (B & C-type), categorized by voltage (415V, 550V, 690V) and current ratings.
Specifications: Fuse links are designed for specific voltage levels with breaking capacities, such as the A-type with 415 V AC at 80 kA and 240/250 V DC at 40 kA.
Dimensions and Electrical Characteristics: Detailed dimensions and electrical characteristics, including I2t characteristics and power dissipation values, ensure suitability for various applications.
Comparison and Application Information: A comparison chart highlights Mersen's unique features and ratings. Application guidance is provided for selecting appropriate fuses.
Approvals and Certifications: All products comply with relevant standards, though some items are not ASTA certified.
Specifications: Detailed specifications for fuse types like BNS, BNIT, BTIA, BES, BTCP, with voltage ratings of 415/550 V AC and 250 V DC, and breaking capacities of 80 kA and 40 kA.
Procedures: Procedures for selecting fuses based on application requirements, considering factors like inrush current and ambient temperature.
Standards and Norms: Fuses comply with IEC 60269 standards, tested under conditions exceeding rated voltage by 10%. De-rating is recommended for temperatures above 40°C.
Recommendations: For capacitor circuit protection, fuses should have a current rating greater than 1.7 times the rated capacitor current. For transformer protection, fuses should be on both primary and secondary sides.
Key Data from Tables and Charts: Tables list fuse types, current ratings, I2T characteristics, and watt loss data, essential for understanding performance and application.
Circuit Protection: Recommendations for fuse link ratings with motor starters, emphasizing Type 2 coordination with Mersen fuses.
Protection Against Electrical Shock: Local standards dictate disconnecting times, with a table of maximum fault loop impedance (Zs) values for gG fuse links at 240V.
BS88 Fuse Holders: Comply with BS88-1 and BS88-6: 1988 standards, offering various connection types and safety features.
Specifications: Details for fuse holder types (F1, F2, A1, A2, A3, A4), including voltage and current ratings, connection types, and installation tools.
Technical Characteristics: Rated for various voltages and currents, with dimensions and panel drilling specifications.
Approvals and Contact Information: Concludes with approval notes and contact information for Mersen offices worldwide.
See more

Catalog excerpts

BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-1

Expertise, our source of energy W

 Open the catalog to page 1
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-2

Powerful presence of the world's leader on the circuit protection market, Mersen Electrical Protection Activity, offer innovative solutions to enhance the safety of low voltage installations and equipments. Above and beyond the supply of products, the company also provides added value in the form of technical support for OEMs, electrical contractors, panel builders, plant maintenance department and utilities. As a global player, Mersen has established production facilities on every continent to optimise the offering (France, Tunisia, United States, Canada, Mexico, India, Japan and P.R. of China)....

 Open the catalog to page 2
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-3

Range Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Comparison Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Offset Bolted Tag Fuse Links (A-type). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reference Data (415V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-4

4 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 4
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-5

Mersen • BS88 LV Fuse Links & Fuse Holders 5

 Open the catalog to page 5
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-6

Note: 1. A3C, A4C represents compact dimensions with respect to BS88/ IEC60269 standards specified dimensions 2. A4X represents extended rating with respect to BS88 / IEC 60269 specified ratings 2. Note that items marked with an * are not ASTA certified 6 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 6
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-7

Mersen • BS88 LV Fuse Links & Fuse Holders 7

 Open the catalog to page 7
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-8

CENTRAL BOLTED TAG FUSE LINKS (B & C-TYPE) 8 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders Note: 1. B1C, B2C represents compact dimensions with respect to BS88/ IEC60269 standards specified dimensions 2. B3X represents extended rating with respect to BS88 / IEC 60269 specified ratings 2. Note that items marked with an * are not ASTA Certified

 Open the catalog to page 8
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-9

Electrical characteristics Mersen • BS88 LV Fuse Links & Fuse Holders 9

 Open the catalog to page 9
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-10

10 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holder

 Open the catalog to page 10
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-11

CUT-OFF CURRENT CHARACTERISTICS Mersen • BS88 LV Fuse Links & Fuse Holders 11

 Open the catalog to page 11
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-12

OFFSET BLADE/OFFSET TAG FUSE LINKS (F&A-TYPE) Rated Voltage: 415/550 V ac Breaking Capacity: 80 kA 250 V dc Breaking Capacity: 40 kA Note: 1. A2C, represents compact dimensions with respect to BS88/ IECB02B9 standards specified dimensions 2. Note that items marked with an * are not ASTA Certified 12 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 12
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-13

Mersen • BS88 LV Fuse Links & Fuse Holders 13

 Open the catalog to page 13
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-14

14 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 14
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-15

Mersen • BS88 LV Fuse Links & Fuse Holders 15

 Open the catalog to page 15
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-16

Note: 1. A4C represents compact dimensions with respect to BS88/ IECB02B9 standards specified dimensions 2. Note that items marked with an * are not ASTA Certified 16 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 16
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-17

OFFSET BOLTED TAG FUSE LINKS (A-TYPE) Mersen • BS88 LV Fuse Links & Fuse Holders 17

 Open the catalog to page 17
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-18

CENTRAL BOLTED TAG FUSE LINKS (B&C-TYPE) Note: 1. Note that items marked with an * are not ASTA Certified. 18 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 18
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-19

Mersen • BS88 LV Fuse Links & Fuse Holders 19

 Open the catalog to page 19
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-20

20 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holder

 Open the catalog to page 20
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-21

CUT-OFF CURRENT CHARACTERISTICS Mersen • BS88 LV Fuse Links & Fuse Holders 21

 Open the catalog to page 21
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-22

Power dissipation charte 22 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 22
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-23

BS88 fuses comply with IEC 60269 standards. They are tested under a voltage at least 10% higher than the fuse rated voltage. Ambient temperature Above an ambient of 40°C a general de-rating of 0.5% of the fuse-link rated current per excess degree centigrade is recommended. Cable protection gG fuses protect cables against both overload and short circuit. The cable is protected when the following conditions are fulfilled. IB < IN < Iz IF < 1.45Iz IB: Operating current of the cable Iz: Maximum current carrying capacity of the cable L : Rated current of the fuse N IF: Conventional fusing current...

 Open the catalog to page 23
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-24

For Offset Blade & Bolted Tag Fuse Links For Offset Blade & Bolted Tag Fuse Links Fuse holders from Mersen comply with BS88-1 and BS88-6: 1988. The fuse holders are designed to prevent direct contact with live parts when being inserted or removed, preventing any likelihood of inadvertent contact with live metal. Also, cable terminals within the fuse base are fully shrouded when holder is removed (product is IP2X Classified). Type Of Connection BFF Front wire connected (front-front) 3 connection styles possible: Mounting on board with cable upstream and downstream BBB Back stud connected (back-back)...

 Open the catalog to page 24
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-25

Mersen • BS88 LV Fuse Links & Fuse Holders 25

 Open the catalog to page 25
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-26

26 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 26
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-27

Front Front Connection (BFF) Back Back Connection (BBB) Front Back (Busbar) Connection (BFB) Mersen • BS88 LV Fuse Links & Fuse Holders 27

 Open the catalog to page 27
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-28

Front Front Connection (BFF) Back Back Connection (BBB) Front Back (Busbar) Connection (BFB) FUSE HOLDER TYPE 28 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holders

 Open the catalog to page 28
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-29

Mersen • BS88 LV Fuse Links & Fuse Holders 29

 Open the catalog to page 29
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-30

30 Mersen •Mersen • BS88 LV Fuse Links & Fuse Holder

 Open the catalog to page 30
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-31

Mersen • BS88 LV Fuse Links & Fuse Holders 31

 Open the catalog to page 31
BS88 fuse-links gG gM Type A-B-C-F 415 to 690VAC-32

MeRseivI Expertise, our source of energy W GLOBAL EXPERT IN ELECTRICAL POWER AND ADVANCED MATERIALS. NORTH AMERICA USA Mersen USA Newburyport-MA L.L.C. 374 Merrimac Street Newburyport, MA 01950 Tel: +1 978-462-6662 FRANCE Mersen France SB S.A.S. Rue Jacques de Vaucanson F-69720 Saint-Bonnet-de-Mure Tel: + 33 4 72 22 66 11 UNITED KINGDOM Mersen UK Portslade Ltd. South Street Portslade, East Sussex BN41 2LX Tel: +44(0) 1273 415701 [email protected] INDIA Mersen India Pvt. Ltd. # 19, 4th Cross, Bommasandra Industrial Area, Bangalore - 560099 Tel: +91 80 27834001/5/6 E-mail: [email protected]...

 Open the catalog to page 32

All Mersen Power Transfer Technologies catalogs and technical brochures

  1. CG677

    2  Pages

  2. BOOSTEC® SiC

    9  Pages

  3. PRODUCT CATALOG

    348  Pages

  4. Ski lifts

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.