Product catalog summary
Overview: The document provides technical specifications and details for Mersen's UL 508 Non-Fusible Disconnect Switches, specifically the M-series Load Break Switches (M163 – M803). These switches are designed for industrial applications, offering compact and robust solutions for electrical isolation and motor disconnection.
Specifications:
  • Voltage and Current Ratings: Up to 600VAC and 20-80A, suitable for motor disconnection up to 40hp.
  • Mounting Options: DIN-rail, base, or door-mounting.
  • Handles and Shafts: Various options available, including padlockable handles.
  • Contacts: Double-break, silver-plated contacts for enhanced durability.
Applications:
  • Line-of-sight disconnect
  • Electrical isolation
  • Branch-circuit switch
  • Motor disconnect
Approvals: UL 508 listed (E196672) and IEC 60947-3 compliant.
Technical Data:
  • General Purpose Amp Rating: 20-80A with a power factor of 0.7-0.8.
  • Maximum Operating Voltage: 600V.
  • Horsepower Ratings: Vary by voltage and phase, with specific ratings for 240V, 480V, and 600V.
  • Short Circuit Ratings: Detailed for various fuse types (CC, J, T, RK1, RK5).
  • Endurance: Electrical endurance of 6,000 cycles and mechanical endurance of 20,000 operations.
IEC 60947-3 Technical Data:
  • Rated Insulation Voltage: 750V.
  • Dielectric Strength: 6kV.
  • Rated Impulse Withstand Voltage: 8kV.
  • Operational Current Ratings: Detailed for AC-21A, AC-22A, AC-23A, and DC-21A, DC-22A, DC-23A across various voltages.
  • Breaking Capacity: Specified for AC-23A and DC-23A.
  • Short Circuit Current Ratings: Conditional ratings provided for different voltages and fuse sizes.
Accessories: Options include fourth poles, neutral poles, terminal shrouds, and auxiliary contacts with specific configurations for door-mounted switches.
Additional Features: The switches are designed for high mechanical endurance and are suitable for use in various environmental conditions, with specific torque and cable size requirements for installation.
See more

Catalog excerpts

UL 508-1

UL 508 Non-Fusible Disconnect Switches Amps: 20, 30, 40, 63, and 80A. Suitable as motor disconnect up to 40hp. F E AT U R E S / BENEFITS: switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect. Extremely compact and robust, these switches have a variety of mounting options including DIN-rail, base, or door-mounting. A wide assortment of handles, shafts and accessories is available to accommodate any installation requirement. Line-of-sight disconnect Electrical isolation Branch-circuit switch Motor disconnect DIN-rail, base, or door mounting Choice of handles and shafts Side-mount auxiliary contacts and additional poles Double-break, silver-plated, contacts ________ Special Configurations DM: Door Mounting © 2018 Mersen. All rights reserved. Mersen reserves the right to change, update, or correct, without notice, any information contained in this datasheet. Catalog number designation The M-series Load Break Switch is the most compact

 Open the catalog to page 1
UL 508-2

UL 508 Disconnect Switches—Front Operated Switch Body Ampere Rating Base Part # Door-Mounted Version Direct Front Operation Locking Handle External Front Operation Selector Style NEMA Type 1, 3R, 12 HSBX, HSRX Door mounted version (no shaft required) HB65 HSBPDM, HSRPDM Pistol Style NEMA Type 1, 3R, 12 NEMA 4X Stainless Steel Shaft— SAxxx (xxx = length in mm) SA105 HSBWDM, HSRWDM B=Black, R=Black Fourth Poles Limited to one additional pole per switch Door mounted switch 4th poles are left-side mounted Neutral Poles Limited to one additional pole per switch 4P40 Door mounted switch neutral poles...

 Open the catalog to page 2
UL 508-3

TECHNICAL DATA ACCORDING TO UL/cULus Part Number pf= 0.7...0.8 General Purpose Amp Rating Maximum Operating Voltage Max. horsepower rating / motor FLA current pf= 0.4...0.5 Three phase Single phase Short circuit rating with fuse Endurances Min. electrical endurance, pf. 0.75...0.8 Mechanical endurance Terminal lug kits Wire range Torque Maximum fuse size Fuse type Fuse type Fuse type Fuse type Fuse type Fuse type Fuse type A V HP/A HP/A HP/A HP/A HP/A A kA kA kA kA kA kA kA oper. cycles operations Wire tightening Lug mounting

 Open the catalog to page 3
UL 508-4

TECHNICAL DATA ACCORDING TO UL/cULus Part Number pf= 0.7...0.8 General Purpose Amp Rating TECHNICAL DATA ACCORDING TO IEC 60947-3 Rated insulation voltage and rated Pollution degree 3 operational voltage AC20/DC20 Dielectric strength Rated impulse withstand voltage Ambient 40 °C 2) Rated thermal current and rated Ambient 40 °C 2) operational current AC20/DC20 Ambient 60 °C ...with minimum conductor cross Rated operational current, AC-21A Rated operational current, AC-22A Rated operational current, AC-23A Rated operational current / poles in series, DC-21A Rated operational current / poles in...

 Open the catalog to page 4

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.