6001, 6002 Flow monitor and indicator for liquids and gases-1

Operating Data • Float measuring principle • Water treatment • Chemical industry • Cooling systems • Easy installation • Good chemical resistance • Direct readable scale adjustable limit switches, analog transmitter Installation hints • The operating instruction for type series 6000 must be observed! • Download: www.meister-flow.com Measuring Ranges Flow ranges (water at 20 °C)

 Open the catalog to page 1
6001, 6002 Flow monitor and indicator for liquids and gases-2

Dimensions and weights of Type 6001 Dimensions and weights of Type 6002 (DIN 2501) Steel, coated Borosilicate glass Steel, coated * Borosilicate glass Steel, coated * Borosilicate glass Steel-PTFE / PTFE Steel, coated * Borosilicate glass Steel / PTFE ' Stainless steel 1.4404 on request '* Other gasket materials on request * Stainless steel 1.4404 on request ** Other gasket materials on request The general business terms of Meister Stro'mungstechnik GmbH are valid • All rights reserved

 Open the catalog to page 2
6001, 6002 Flow monitor and indicator for liquids and gases-3

Measuring ranges Float type Tube Stainless Steel 1.4404 Type C Pressure drop for Model-No. Water Float type The general business terms of Meister Stro'mungstechnik GmbH are valid • All rights reserved

 Open the catalog to page 3
6001, 6002 Flow monitor and indicator for liquids and gases-4

For measuring ranges from 40 to 400 l/h water The magnet in the float operates the micro switch (change over contact) mounted in an aluminium case. - 1 or 2 adjustable limit switches - Switch values: 3 (1) A, 250 V ~ (VDE/CEE) - Hysteresis: ± 10 % from full scale - Mechanical lifetime: 107 switch operations (gold-plated contacts on request) The general business terms of Meister Stro'mungstechnik GmbH are valid • All rights reserved

 Open the catalog to page 4
6001, 6002 Flow monitor and indicator for liquids and gases-5

For measuring ranges from 40 - 400 l/h water and 0,7 - 7 Nm3/h air The magnet in the float operates the inductive contact in an - 1 or 2 adjustable limit switches - Power supply: 8 V DC (switch amplifier) switch amplifier (on request) Model NAMUR (DIN 19234), for 1 or 2 inductive contacts - Input: intrinsically safe circuit EEx ia IIC * requires amplifier realy For measuring ranges from 6 - 60 l/h water and 0,1 -1 Nm3/h air The optical contact (infrared light) will be activated by interruption of the light beam through the float. The sensor is mounted in a PVC support. The relay is in a separate...

 Open the catalog to page 5
6001, 6002 Flow monitor and indicator for liquids and gases-6

For measuring ranges from 40 - 400 l/h water and 0,7 - 7 Nm3/h air Attached to the body of the flow monitor is a movable plastic case fitted with an integreated reed switch. The electrical wiring is contained in a seperate IP 40 housing - Power supply: - Electrical connection: - Ambient temperature ± 7 % from full scale E-Mail: [email protected] Internet: www.meister-flow.com The general business terms of Meister Stromungstechnik GmbH are valid • All rights reserved