CA 164 - 1

DATA SHEET Piezoelectric Accelerometer Type CA 164 CHARACTERISTICS High temperature capability -70°C to +350°C Operational as loose part monitoring accelerometer Easy mounting with differential stud MA 116 and MA123 Cobalt free Will meet NRC guide 1.133, DIN 25.471.1 IEEE 323-1974 Proven reliability Internal case insulation Frequency response: 1 Hz to 10,000 Hz Sensitivity 20 pC/g The CA 164 accelerometer has a centre mounted symmetrical compression mode polycristalline element. The transducer is designed for long-term loose part monitoring or development testing. It is fitted with an integral mineral insulated cable (twin conductors) which is terminated with a VM Lemo connector for use with differential charge converters. Another version offered has a triax integral mineral insulated cable terminated with a LEMO triax connector. WEIGHT Accelerometer Integral cable Direction of acceleration to provide a positive signal 1 Mounting configuration with stud Type MA 109 P/N 809-109-000-011 Nominal mounting torque: 5.5 Nm ±0.5 Nm (48.67IN-LB) Mating connector: 144-164-000-0X, Lemo 2 pole type FDS 302 N for twin cable, screen connected. 144-164-000-1X, Lemo triax type FFA.OS.650.CLAC 27 for coax cable O.D. 2.2 mm 2 Mounting configuration with differential stud 2c Position the assembly 2b on the thread of the structure. Make sure the position of the vibration transducer is approximately 15 degrees before its final position. Hold the vibration transducer and turn the knurled ring clockwise until it butts. Apply a torque of 5.5 Nm ±0.5 Nm (48.67IN-LB) to the vibration transducer (not to the knurled ring). Screw the differential stud into the

Open the catalog to page 1
CA 164 - 2

SPECIFICATIONS Input power requirements : None Signal transmission : 2 pole system insulated from casing, charge output Signal processing : Charge converter OPERATING (at +23°C ±5°C) Sensitivity (at 120 Hz) : 14.1 pC/g ±5% 20 pC/g ±10% at 300°C Dynamic measuring range (random) : 0.0005 g to 500 g peak Overload capacity (spikes) : Up to 1000 g peak Linearity : ±1% over dynamic measuring range Transverse sensitivity : <5% Resonant frequency (mounted) : >40 kHz nominal Frequency response - 1 to 7000 Hz : ±5% (lower cutoff frequency is determined by the electronic used) - 7000 to 10,000 Hz :...

Open the catalog to page 2

All MEGGITT SA catalogs and technical brochures

  1. GSI 127

    7 Pages

  2. CA 962

    2 Pages

  3. CA 952

    2 Pages

  4. CA 901

    4 Pages

  5. VM600 systems

    14 Pages