STX40 Portable cable fault location system
Open the catalog to page 1STX40 – second to none! Made for demanding outdoor use Modern fault location systems have to meet steep requirements to be considered truly portable and thus outdoor-ready for use in the field. Such units must be lightweight, rugged, hardened to hostile and challenging environments, very mobile in adverse terrain and as compact in size as possible. The units must also be operable in rain as well as in very bright daylight conditions with intense sunshine. The STX40 is the only fault locating unit in its class with such a degree of outdoor-readiness. No competitor product comes even close. The...
Open the catalog to page 2Modern cable fault location with automation and central control The portable STX40 sets a new standard for modern cable fault location technology: a compact, fully integrated solution for finding high-resistance, low-resistance and intermittent faults in low-voltage (LV) and medium-voltage (MV) power cables, all in a single robust housing. The STX40 comes with the latest generation built-in Teleflex® RDR cable radar for time domain reflectometry (TDR), and also includes an insulation testing module, a powerful high voltage (HV) DC source, a multi-stage surge generator (thumper) for pinpointing...
Open the catalog to page 3Performance otherwise only possible in cable test vans The well-equipped toolbox for cable fault location Fault finding on PILC/MIND cables Cable faults in underground installations are as diverse as the cable designs themselves. Some are low-resistance faults, often detectable with a TDR but rather difficult to pinpoint; others are high-resistance faults and require HV prelocation methods such as ARM, yet are comparatively straightforward to pinpoint once measured in distance; and some faults appear and disappear without warning - the so-called intermittent faults. Each has its own character,...
Open the catalog to page 49 fault locating techniques The STX40 is a fault locating powerhouse and offers 9 different built-in technologies to find faults successfully. Insulation resistance measurement DC breakdown detection (DC hipot) Fault conversion by DC burning Arc Reflection (ARM) with inductive ARM filter, including BestPicture® Multishot technology Prelocation with Time Domain Reflectometry (TDR / cable radar) Voltage decoupling (Decay) Detecting and pinpointing LV earth faults and MV sheath faults using the voltage gradient method (step voltage method) together with ESG NT2 Pinpointing high-resistance faults...
Open the catalog to page 55 SAFETY RULES Working in a de-energised state Safety is paramount The STX40 solution comes with a sophisticated built-in safety system compliant to numerous national and international safety standards, for example: 1 - Turn-off power and disconnect. 2 - Secure against reconnection and reclosing. 3 - Verify that the installation is de-energised 5 - Cover or close off adjacent live parts. ■ DIN EN 50191 and VDE 0104: Erection and operation of electrical test equipment ■ DIN EN 61010: Safety requirements for electrical measurement equipment, control, and laboratory ■ VDE 0105: Operation of electrical...
Open the catalog to page 8You will not be left alone: training & support from the specialists A tremendous benefit to purchasing any test instrument from Megger is that we won’t disappear after your purchase! We do have broad and in-depth technical expertise, application knowledge and experience in the field which we can all share with you. We have invested heavily in creating a local support network of engineers to provide a rapid response by people who understand your challenges and needs. Product and application training can also be offered at your premises or in specialist training facilities around the world. More...
Open the catalog to page 9What else can we offer you for your daily demands? Localises cable routes Detects high-resistance cable faults in the main insulation Detects sheath faults DIGIPHONE+2 Pinpointing with magnetic-acoustic surge wave receiver DIGIPHONE+2 NT SET Additionally sheath fault location using 50/60 Hz voltage gradient method DIGIPHONE+2 NTRX SET Additionally cable tracing with detection of current direction Datasheet digiPHONE+ 2 series Detects low-resistance cable faults in the main insulation
Open the catalog to page 10Application note and case studies about STX40 and digiPHONE+2 Cable fault location on multi-core signalling cables in railway applications Fault location on a MV cable in a wind farm APPLICATION NOTE Title Main Secondary title Cable fault location on multi-core signalling cables in railway applications using the STX40 CASE STUDY Title Main Secondary title Locating a fault on a medium voltage cable in a wind farm V01 - APRIL 24 Fault location on a MV cable in a wind farm Fault location on MV cable in a wind farm (switchgear to wind turbine) EN CASE STUDY Title Main Secondary title Locating a fault...
Open the catalog to page 11Megger Germany GmbH · Dr.-Herbert-Iann-Str. 6 · D-96148 Baunach Tel. +49 (9544) - 680 · Fax +49 (9544) - 2273 [email protected] www.megger.com The information in this document is subject to change without notice and should not be construed as a commitment by Megger Germany. Megger Germany assumes no responsibility for any errors that may appear in this document. STX40_BR_EN_V03.pdf The word ‘Megger’ is a registered trademark. Copyright ©
Open the catalog to page 1216 Pages
16 Pages
8 Pages
8 Pages
8 Pages
12 Pages
12 Pages
20 Pages
20 Pages
16 Pages
4 Pages
12 Pages
8 Pages
8 Pages
4 Pages
4 Pages
8 Pages
20 Pages
16 Pages
4 Pages
8 Pages
4 Pages
8 Pages
8 Pages
8 Pages
12 Pages
12 Pages