LIFETEK PMS
3Pages

{{requestButtons}}

Catalog excerpts

LIFETEK PMS - 1

MEGA SYSTEM POLLUTION CONTROL SYSTEMS The LIFETEK PMS is a continuous control unit for sampling atmosphere particles in OUTDOOR environment in compliance with the regulation UNI EN 12341:2014. The system is compact and easy to carry. It can be used in external environment thanks to the cabinet where the entire system is stored otherwise it can be placed in a mobile laboratory providing to the instrument the special adapter for the sampling head. It's made of materials that grant suitable protection against atmospheric agents. The LIFETEK PMS is a control unit for continual monitoring of the atmosphere particulate matter by the gravimetric method on filtering membrane of 47 mm. The sequential system for filter changes has an autonomy of 16 filter which combined with the automatic flow control, allows the continuous monitoring without the supervision of a technician; it also offer the possibility to change the exposed filters without interrupting the sampling in progress. The ventilation system of the sampling tube guarantees a temperature difference lower that 5 °C between the filter and the sampling point with an ambient temperature greater or equal than 20 °C (UNI EN 12341:2014 - point 5.1.4). The straight path of the aspiration tube and the separation of the filter storage from internal or radiant heating sources allows to gather and keep intact samples. The entire system has been designed with the goal of eliminating all the possible causes of jamming filters during the loading operations. So the filter loading occurs for gravity (falling from the top to the bottom) and not by the use of a compressor which pushes them. The pump works on the effective power needed to sample and to at the maximum of its capabilities so it grants a longer duration of the palette greatly affecting the maintenance costs. The pump also is completely soundproof; this allow to install the instrument in residential area where it's fundamental to have a low background noise not to disturb during the night hours. The sampling system is supplied with a GSM modem to remotely manage sampling and alarms by the use of SMS. A conditioning and thermoregulated heating system allows to use the system in extreme environment conditions with compromising the electronical parts. The instrument id supplied with a Peltier conditioning system which allows the storage of the sampled filters at a controlled temperature inferior than 23°C (UNI EN 12341:2014 - point 5.1.8). It's also possible (optional) to supply the sequential system with sensors for the measurement of meteorological parameters (wind speed and direction, humidity, etc.) or connect it with an existing weather station to acquire its parameters. The modularity of the sampling heads allows to use the system even with USEPA 40, CFR Part 50 heads. The instrument can also be supplied with an optional interface to connect an external electro valves system (SELECT 8) for sampling total dust (TSP) with an autonomy of 8 or 16 filters. The instrument is supplied with a complete testing report. Note: The test report also specifies the calibration procedure used and the primary reference standards. The primary standards used are certified by LAT Centres or by international Calibration Centres accredited by bodies which are members of E.A. - European cooperation for Accreditation (an association representing the European accreditation bodies Mega System srl - Via Don Fracassi, 41 - 20010 Bareggio (Milano) - Italy Phone: +39 02.90361622 - Fax: +39 02.90366880 E-mail: info@megasystemsrl.com - Web: www.megasystemsrl.com Rev.: ST_AMB 01 ENG R01 [LIFETEK PMS].docx Pagina 1 di 3

Open the catalog to page 1
LIFETEK PMS - 2

MEGA SYSTEM POLLUTION CONTROL SYSTEMS Quick connection to the sampling heads. Constant flow with automatic loss compensation of the load losses. In case of elevated pressure drop on the filter the system allows to continue the sampling in progress moving to the next filter and recording the event. Electronic system for the regulation of the flow which allows real time updates of the flow itself which grant a constant flow of 2,3 m3/h in the sampling zone where the granulometric separation occurs in such way to maintain constant air speed at the entrance of the fractionator. The loaders are...

Open the catalog to page 2
LIFETEK PMS - 3

MEGA SYSTEM POLLUTION CONTROL SYSTEMS TECHNICAL SPECIFICATIONS FILTER TEMPERATURE SENSOR Temperature sensor: digital Range: -10 - 50 °C Resolution: 0,1 °C Precision: ± 2 °C Linearity: ± 2 °C (software linearization) STORED FILTERS TEMPERATURE SENSOR Temperature sensor: digital Range: -10 - 50 °C Resolution: 0,1 °C Precision: ± 2 °C Linearity: ± 2 °C (software linearization) VACUUM SENSOR (load losses of the line) Range: 0 - 760 mmHg Resolution: 1 mmHg Precision: ± 5mmHg BAROMETRIC PRESSURE SENSOR Range: 800 - 1100 mbar Resolution: 0,1 mbar Precision: ± 2 mbar PUMP Rotary vane pump of 6m3/h...

Open the catalog to page 3

All Mega system srl catalogs and technical brochures

  1. ISOCHECK SRB

    3 Pages