Catalog excerpts
Safety Relief Valve SL 5 Product information © 01.2023
Open the catalog to page 1Reprint prohibited!
Open the catalog to page 2Table of contents Application, characteristics, technical data 4 Application 4 Characteristics 4 Type of model / Options 4 Technical data 5 Structure and function 6 Installation example 6 Sectional view 6 Measuring unit diameter 7 Setpoint spring table 7 Flow rate capacity 7 Dimensions, connection, and weight 8 Dimensions and weight 8 Dimensional drawings 8 Order data 9 Contact 11 Notes 13 Observe the following publications in relation to ATTENTION installation, start-up and maintenance: DVGW - work sheets G 491 and G 600 Operating and Maintenance Instructions SL 5 List of abbreviations and...
Open the catalog to page 3Application, characteristics, technical data Application Safety relief valve (SRV), direct-acting (operating without auxiliary power), for systems acc. to DVGW Code of Practice G 491 (A) and G 600 (A) (TRGI) Can be used for the gases defined in DVGW Code of Practice G 260 / G 262 and neutral non-aggressive gases. (other gases on request) Characteristics • Horizontal or vertical installation Type of model / Options (see page 9) • lack epoxy resin coating B • NPT connection thread • Biogas & coke oven gas version (max. 0.1% H2S)
Open the catalog to page 4Technical data Type Max. allowable pressure PS 3 bar Nominal width Material Housing / actuator housing/ Die-cast aluminum Temperature range, Class 2 (operating/ambient temperature) Ex protection The mechanical parts of the device do not have any potential ignition sources of their own and therefore do not fall within the scope of ATEX 95 (94/9/EC). Electrical components fitted to the device comply with the ATEX requirements. Preferred installation position For all nominal widths, the direction of flow is indicated by an arrow on the housing. Overhead installation position only after...
Open the catalog to page 5Application, characteristics, technical data Structure and function The spring-loaded safety relief valve SL 5 is used for reducing short-term pressure surges upstream of gas consumption systems or preventing an inadmissibly high pressure increase due to escaping gas, and is intended to protect downstream system components from excessive pressure levels. The safety relief valve is composed of the actuator housing and the “control device” functional unit. In the closed position, the gas flows into the actuator housing in the direction of the arrow. There the inlet pressure acts on the...
Open the catalog to page 6Application, characteristics, technical data Measuring unit diameter Nominal width Connection Setpoint spring table Pressure range (mbar) Spring data Spring no. Flow rate capacity (with an inlet pressure of 115% of the set pressure)
Open the catalog to page 7Dimensions, connection, and weight Dimensions and weight Nominal width DN Dimensional drawing Note Observe the following publications in relation to installation, start-up, and maintenance: DVGW - work sheets G 491 and G 600 Operating and Maintenance Instructions SL 5 For all nominal widths, the direction of flow is indicated by an arrow on the housing.
Open the catalog to page 8Types of models / Options Black epoxy resin coating To protect the safety relief valves from influences in aggressive atmospheres. Version for biogas & coke oven gas NPT connection thread Order data Example: Order selection Safety relief valve: Order code: Acceptance test certificate to EN 10204/3.1 without acceptance test certificate with acceptance test certificate Special model - Black epoxy resin coating - Version for biogas & coke oven gas In every selection group, only one option can be selected in each case.
Open the catalog to page 9The Medenus plus 10 reasons for good business relations 1. Consultancy expertise and quality standards developed over decades 2. Broad and proven standard range of feedback controllers 3. Modern, fast and efficient production for series products and for individual orders 4. Customer-specific design of pressure regulators and vacuum regulators and special designs 5. Guaranteed deadline compliance with a delivery deadline guarantee 6. Fast response time in all matters 7. Sufficiently large parts storage for production and spare parts 8. Customer-specific theory & practice training courses 9....
Open the catalog to page 10Contact Management ALEXANDER CHRISTIANI Technical Inside Sales Department MINDAUGAS PECKAITIS Phone: Mail: Head of Sales & Marketing FRANZ FEICHTNER Inside Sales Department SEBASTIAN HUCKESTEIN Head of Inside Sales Department MANUEL SCHEPP Inside Sales Department STEFANIE MÜLLER If you want to know more about solutions from MEDENUS for the gas industry, please contact your local contact person or go to our internet site at www.medenus.de Trade representation worldwide medenus.de/de/kontakt.html Gas-Druckregeltechnik GmbH Im Langen Feld 3 D-57462 Olpe Phone: +49 (0)2761 82788-0 Fax: +49...
Open the catalog to page 11In the download area of our homepage, this document is available in different languages. You can use the following QR codes and links to go directly to this document in your language.
Open the catalog to page 13MEDENUS Gas-Druckregeltechnik GmbH Phone Fax Im Langen Feld 3 / D-57462 Olpe info@medenus.de www.medenus.de
Open the catalog to page 16All MEDENUS Gas- Druckregeltechnik GmbH catalogs and technical brochures
-
Safety relief valve - SL 10
16 Pages
-
Safety shut-off valve - S 100
20 Pages
-
Safety shut-off valve - S 50
18 Pages
-
Gas Pressure Regulator R51
16 Pages
-
Gasfilter DF50
16 Pages
-
product leaflet RS254/255
24 Pages
-
product leaflet RS250/251
24 Pages
-
product information RSP 254/255
28 Pages
-
R101
20 Pages
-
R105
20 Pages
-
S104
20 Pages