TPAC1007
14Pages

{{requestButtons}}

Catalog excerpts

TPAC1007 - 3

1. Introduction To grant a fast setup of the device please follow carefully the information in this manual. 1.1. Staff skill Products described in this manual are devoted to PLC programmers or automation experts only. MECT S.r.l. declines any responsibility about malfunctioning or damage caused by incorrect use of MECT devices, due to noncompliance to this manual information. MECT S.r.l has an help desk. 1.2. Simbols Danger Follow this advice to avoid people injury. Warning Follow this advice to protect the device. Caution Follow this advice to have a more effective performance. ESD (...

Open the catalog to page 3
TPAC1007 - 4

1.3. Terms PLC: Terminals: System: 1.4. Security Attention Switch off devices before connecting them. ESD (Electrostatic discharge) Modules have electronic components that can be damaged by. electrostatic discharge. Be sure to be connected to ground when handle the devices. The instrument has no power switch and no internal fuse, but it powers on immediately after connecting a correct power supply input (check the power supply value on the instrument label). Keep the power supply line as short as possible and keep it separate from other power lines. For security reasons it is necessary to...

Open the catalog to page 4
TPAC1007 - 5

TPAC1007 mect srl On TPAC1007 are up to 1 Kbyte of retentive variables stored on flash. The device is also able to manage an up to 8GB wide, micro SD card. The SD card is factory mounted on request. A real-time clock buffered RAM maintains the date and time up to four months with the device turned off. TPAC1007 is equipped with a micro PLC to make a small automation of the process. The device can be applied in horizontal or in vertical design with the option "V" (see following pictures). Figure 1: Front view TP1007 (horizontal version) Figure 2: Front view TP1007 (vertical version)

Open the catalog to page 5
TPAC1007 - 6

TPAC1007 mect srl 2.1. Specification TPAC1007 is based on a multiprocessor system. PLC and HMI are based on a 454MHz ARM9. Table 1 PLC Hardware characteristics PLC Processor RAM FLASH Non volatile variables Real Time Clock Screen Touch screen Ethernet Micro-USB Micro SD PLC software characteristics OS PLC Graphics CAN ModBus Storage memory LINUX 2.35 IEC61131-3 Based on QT library CanOpen 2.0 Modbus RTU master Possibility of history storage Field bus main features RTU Modbus TCP Modbus Master 2 wires Client ARM926JE 454MHz 128MB 128MB On FLASH memory Yes with rechargeable battery TFT 480 x...

Open the catalog to page 6
TPAC1007 - 7

3. Hardware Installation In the following figures see the TPAC1007 dimensions. 3.1. Mechanical dimensions Side view Rear view Figure 4 Side view

Open the catalog to page 7
TPAC1007 - 8

Mechanical Material ABS, Polycarbonate 27.7 mm x 159 mm x 83 mm Dimensions W x L x H Mounting plate 127mm x 68mm Installation Panel installation Environmental conditions Operative temperature 0 °C ... 55 °C Storage Temperature -20 °C ... +85 °C Relative Humidity 5 % a 95 % no condensation Electric isolation Air clearance According to IEC 60664-1 Pollution 2 According to IEC 61131-2 Protection Rear protection IP 20 Front protection IP65 EMC EMC according to EN 61000-6-2 (2001) Test specification Values Class EN 61000-4-2 ESD EN 61000-4-3 electromagnetic fields EN 61000-4-4 burst EN 61000-4-5...

Open the catalog to page 8
TPAC1007 - 9

40 dB (µV/m) 47 dB (µV/m) Emissions according to EN 61000-6-3 (2001) Test specification Limit values/IQPI EN 55022 (AC supply, 66 ... 56 dB conducted) (µV) (µV) 56 dB 60 dB (µV) EN 55022 (DC supply/data, 40 ... 30 dB conducted) (µA) (µA) 30 dB EN 55022 (radiated) 30 dB (µV/m) 37 dB (µV/m) Attention Install the device in a panel with no more than 55 °C. Panel mount 3.2.1. Distance System must be installed with a space for heat dissipation and cabling. Avoid cabling superimposing to avoid EMC problems. Figure 6A: Horizontal mounting

Open the catalog to page 9
TPAC1007 - 10

Figure 6B: Vertical mounting In the following figure see the wiring diagram.

Open the catalog to page 10
TPAC1007 - 11

Table 3 TP1007 Power Supply Micro-USB Ethernet Serial ouputs 24Vdc/Vac -10 /+20% 250mA (24Vdc) 2.0 Bit rate: 100Mbit/sec RS485 Modbus half duplex (hardware configuration) or CANopen Power supply 4.2.1. Isolation Device has no galvanic isolation between input, output and power supply. 4.2.2. System power supply TPAC1007 has a 24Vdc/Vac 20%) according to the scheme in the figure. System is protected against reverse power supply. 4.2.3. Fuse System has no internal fuse , so is suggested the use of an external 500mA fuse for the panel power supply. Attention A wrong value for the power supply...

Open the catalog to page 11
TPAC1007 - 12

4.3. ModBus wiring ModBus on TPAC1007 is a 2 wire RS485 serial line, on the terminal board on pins: Table 4 Description Linea + Linea - Example of a wiring of a system composed by:

Open the catalog to page 12
TPAC1007 - 13

4.4. CANOpen wiring The CANopen interface on TPAC1007 must be connected to the terminal block on the pins shown in the table. Table 5 Description Linea Linea + Example of a wiring of a system composed by: MPNC010 MPNC030 TPAC1007

Open the catalog to page 13
TPAC1007 - 14

5.1. USB TPAC1007 has a Micro-USB 2.0 host for: software update data storage: datalogger connect USB peripherals as printers, mouse, etc. Specific connection of external peripherals are implemented on request. 5.2. Ethernet TPAC1007 has a 10/100Mbit/s ethernet port with auto-configuration, moreover the connection cable between TPAC1007 and a personal computer can be either straight either cross. 6. HMI To set the TPAC1007 is necessary to develop a software in QT Creator based on QT libraries, custom-tailored on MECT operator panel. A specific tutorial is furnished with the device. The QT...

Open the catalog to page 14

All MECT SRL catalogs and technical brochures

  1. TPAC1008

    22 Pages

  2. TPAC1006

    22 Pages

  3. MPA-MPV M6

    42 Pages

  4. MPA386 M6

    39 Pages

  5. MPP P6

    19 Pages

  6. MPA-MPV P6

    18 Pages

  7. MPX28

    8 Pages

  8. MPSN20

    2 Pages

  9. MPCV015

    20 Pages

  10. MPT390 M6

    61 Pages

  11. MPT91 M1

    66 Pages

  12. MPT90 M1

    46 Pages

  13. MPT60 M1

    45 Pages

  14. MPT100 M1

    35 Pages

  15. MPCIB396 P6

    41 Pages

  16. MPCIB20 M1

    25 Pages

  17. MPCT301 P6

    53 Pages

  18. MPCT300 P6

    37 Pages

  19. MPCT30 P6

    36 Pages

  20. MPCT20 M1

    35 Pages

  21. MP2200 M6

    44 Pages

  22. MP1200 P6

    36 Pages

  23. MPPV340 M6

    40 Pages

  24. MPO347 M6

    40 Pages

  25. MPP323 M6

    42 Pages

  26. MPPV010 P6

    40 Pages

  27. MP45 P6

    18 Pages

  28. MPM P6

    34 Pages

  29. MP30 P2

    15 Pages

  30. MP20 M1

    35 Pages

  31. MPNC030

    12 Pages

  32. TPLC005

    28 Pages

  33. MPNC020

    13 Pages

  34. MPNC010

    25 Pages

  35. TP1070

    15 Pages

  36. TP1057

    15 Pages