1. Introduction To grant a fast setup of the device please follow carefully the information in this manual. 1.1. Staff skill Products described in this manual are devoted to PLC programmers or automation experts only. MECT S.r.l. declines any responsibility about malfunctioning or damage caused by incorrect use of MECT devices, due to noncompliance to this manual information. MECT S.r.l has an help desk. 1.2. Simbols Danger Follow this advice to avoid people injury. Warning Follow this advice to protect the device. Caution Follow this advice to have a more effective performance. ESD (...
Open the catalog to page 31.3. Terms PLC: Terminals: System: 1.4. Security Attention Switch off devices before connecting them. ESD (Electrostatic discharge) Modules have electronic components that can be damaged by. electrostatic discharge. Be sure to be connected to ground when handle the devices. The instrument has no power switch and no internal fuse, but it powers on immediately after connecting a correct power supply input (check the power supply value on the instrument label). Keep the power supply line as short as possible and keep it separate from other power lines. For security reasons it is necessary to...
Open the catalog to page 4TPAC1007 mect srl On TPAC1007 are up to 1 Kbyte of retentive variables stored on flash. The device is also able to manage an up to 8GB wide, micro SD card. The SD card is factory mounted on request. A real-time clock buffered RAM maintains the date and time up to four months with the device turned off. TPAC1007 is equipped with a micro PLC to make a small automation of the process. The device can be applied in horizontal or in vertical design with the option "V" (see following pictures). Figure 1: Front view TP1007 (horizontal version) Figure 2: Front view TP1007 (vertical version)
Open the catalog to page 5TPAC1007 mect srl 2.1. Specification TPAC1007 is based on a multiprocessor system. PLC and HMI are based on a 454MHz ARM9. Table 1 PLC Hardware characteristics PLC Processor RAM FLASH Non volatile variables Real Time Clock Screen Touch screen Ethernet Micro-USB Micro SD PLC software characteristics OS PLC Graphics CAN ModBus Storage memory LINUX 2.35 IEC61131-3 Based on QT library CanOpen 2.0 Modbus RTU master Possibility of history storage Field bus main features RTU Modbus TCP Modbus Master 2 wires Client ARM926JE 454MHz 128MB 128MB On FLASH memory Yes with rechargeable battery TFT 480 x...
Open the catalog to page 63. Hardware Installation In the following figures see the TPAC1007 dimensions. 3.1. Mechanical dimensions Side view Rear view Figure 4 Side view
Open the catalog to page 7Mechanical Material ABS, Polycarbonate 27.7 mm x 159 mm x 83 mm Dimensions W x L x H Mounting plate 127mm x 68mm Installation Panel installation Environmental conditions Operative temperature 0 °C ... 55 °C Storage Temperature -20 °C ... +85 °C Relative Humidity 5 % a 95 % no condensation Electric isolation Air clearance According to IEC 60664-1 Pollution 2 According to IEC 61131-2 Protection Rear protection IP 20 Front protection IP65 EMC EMC according to EN 61000-6-2 (2001) Test specification Values Class EN 61000-4-2 ESD EN 61000-4-3 electromagnetic fields EN 61000-4-4 burst EN 61000-4-5...
Open the catalog to page 840 dB (µV/m) 47 dB (µV/m) Emissions according to EN 61000-6-3 (2001) Test specification Limit values/IQPI EN 55022 (AC supply, 66 ... 56 dB conducted) (µV) (µV) 56 dB 60 dB (µV) EN 55022 (DC supply/data, 40 ... 30 dB conducted) (µA) (µA) 30 dB EN 55022 (radiated) 30 dB (µV/m) 37 dB (µV/m) Attention Install the device in a panel with no more than 55 °C. Panel mount 3.2.1. Distance System must be installed with a space for heat dissipation and cabling. Avoid cabling superimposing to avoid EMC problems. Figure 6A: Horizontal mounting
Open the catalog to page 9Figure 6B: Vertical mounting In the following figure see the wiring diagram.
Open the catalog to page 10Table 3 TP1007 Power Supply Micro-USB Ethernet Serial ouputs 24Vdc/Vac -10 /+20% 250mA (24Vdc) 2.0 Bit rate: 100Mbit/sec RS485 Modbus half duplex (hardware configuration) or CANopen Power supply 4.2.1. Isolation Device has no galvanic isolation between input, output and power supply. 4.2.2. System power supply TPAC1007 has a 24Vdc/Vac 20%) according to the scheme in the figure. System is protected against reverse power supply. 4.2.3. Fuse System has no internal fuse , so is suggested the use of an external 500mA fuse for the panel power supply. Attention A wrong value for the power supply...
Open the catalog to page 114.3. ModBus wiring ModBus on TPAC1007 is a 2 wire RS485 serial line, on the terminal board on pins: Table 4 Description Linea + Linea - Example of a wiring of a system composed by:
Open the catalog to page 124.4. CANOpen wiring The CANopen interface on TPAC1007 must be connected to the terminal block on the pins shown in the table. Table 5 Description Linea Linea + Example of a wiring of a system composed by: MPNC010 MPNC030 TPAC1007
Open the catalog to page 135.1. USB TPAC1007 has a Micro-USB 2.0 host for: software update data storage: datalogger connect USB peripherals as printers, mouse, etc. Specific connection of external peripherals are implemented on request. 5.2. Ethernet TPAC1007 has a 10/100Mbit/s ethernet port with auto-configuration, moreover the connection cable between TPAC1007 and a personal computer can be either straight either cross. 6. HMI To set the TPAC1007 is necessary to develop a software in QT Creator based on QT libraries, custom-tailored on MECT operator panel. A specific tutorial is furnished with the device. The QT...
Open the catalog to page 14All MECT SRL catalogs and technical brochures
-
TPAC1008
22 Pages
-
TPAC1006
22 Pages
-
MPA-MPV M6
42 Pages
-
MPA386 M6
39 Pages
-
MPP P6
19 Pages
-
MPA-MPV P6
18 Pages
-
MP40 P6 Simple imput
16 Pages
-
MP40 P6 Multi input
17 Pages
-
MPX28
8 Pages
-
MPSN20
2 Pages
-
MPCV015
20 Pages
-
MPT390 M6
61 Pages
-
MPT91 M1
66 Pages
-
MPT90 M1
46 Pages
-
MPT60 M1
45 Pages
-
MPT100 M1
35 Pages
-
MPCIB396 P6
41 Pages
-
MPCIB20 M1
25 Pages
-
MPCT301 P6
53 Pages
-
MPCT300 P6
37 Pages
-
MPCT30 P6
36 Pages
-
MPCT20 M1
35 Pages
-
MP2200 M6
44 Pages
-
MP1200 P6
36 Pages
-
MPPV340 M6
40 Pages
-
MPO347 M6
40 Pages
-
MPP323 M6
42 Pages
-
MPPV010 P6
40 Pages
-
MP45 P6
18 Pages
-
MPM P6
34 Pages
-
MP30 P2
15 Pages
-
MP20 M1
35 Pages
-
MPNC030
12 Pages
-
TPLC005
28 Pages
-
MPNC020
13 Pages
-
MPNC010
25 Pages
-
TP1070
15 Pages
-
TP1057
15 Pages