1. Introduction To grant a fast setup of the device please follow carefully the information in this manual. 1.1. Staff skill Products described in this manual are devoted to PLC programmers or automation experts only. MECT S.r.l. declines any responsibility about malfunctioning or damage caused by incorrect use of MECT devices, due to noncompliance to this manual information. MECT S.r.l has an help desk. 1.2. Simbols Danger Follow this advice to avoid people injury. Warning Follow this advice to protect the device. Caution Follow this advice to have a more effective performance. ESD (...
Open the catalog to page 4Security Attention Switch off devices before connecting them. ESD (Electrostatic discharge) Modules have electronic components that can be damaged by. electrostatic discharge. Be sure to be connected to ground when handle the devices. The instrument has no power switch and no internal fuse, but it powers on immediately after connecting a correct power supply input (check the power supply value on the instrument label). Keep the power supply line as short as possible and keep it separate from other power lines. For security reasons it is necessary to have a 2 section power switch with a fuse...
Open the catalog to page 5Figure 1: Front view TP1057 (horizontal version) Figure 2: Front view TP1057 (vertical version)
Open the catalog to page 62.1. Specification TP1057 is based on a multiprocessor system. PLC and HMI are based on a 454MHz ARM9. Table 1 PLC Hardware characteristics PLC Processor RAM FLASH Non volatile variables Real Time Clock Screen Screen (option HR) Touch screen Ethernet USB ARM926JE 454MHz 128MB 128MB On FLASH memory Yes with rechargeable battery TFT 320 x 240 pixel 262k colors TFT 640 x 480 pixel 262k colors Resistive 4 wires 10Mbit/s - 100Mbit/s self recognition Host 2.0 Field bus main features RTU Modbus TCP Modbus Master 2 or 4 wies Server
Open the catalog to page 73. Hardware Installation In the following figures see the TP1057 dimensions. 3.1. Mechanical dimensions Side view Rear view Figure 4 Side view
Open the catalog to page 8Mechanical Material Polycarbonate, Polyamide 6.6 195 mm x 145 mm x 60.5 mm Dimensions W x L x H Mounting plate 139mm x 189mm Installation Panel installation Environmental conditions Operative temperature 0 °C ... 55 °C Storage Temperature -20 °C ... +85 °C Relative Humidity 5 % a 95 % no condensation Electric isolation Air clearance According to IEC 60664-1 Pollution 2 According to IEC 61131-2 Protection Rear protection IP 20 Front protection IP65 EMC EMC according to EN 61000-6-2 (2001) Test specification Values Class EN 61000-4-2 ESD EN 61000-4-3 electromagnetic fields EN 61000-4-4 burst...
Open the catalog to page 979 dB (µV) 73 dB (µV) EN 55011 (radiated) 40 dB (µV/m) 47 dB (µV/m) Emissions according to EN 61000-6-3 (2001) Test specification Limit values/IQPI EN 55022 (AC supply, 66 ... 56 dB conducted) (µV) (µV) 56 dB 60 dB (µV) EN 55022 (DC supply/data, 40 ... 30 dB conducted) (µA) (µA) 30 dB EN 55022 (radiated) 30 dB (µV/m) 37 dB (µV/m) Attention Install the device in a panel with no more than 55 °C.
Open the catalog to page 10mect srl Panel mount 3.1.1. Distance System must be installed with a space for heat dissipation and cabling. Avoid cabling superimposing to avoid EMC problems. Figure 6A: Horizontal mounting Figure 6B: Vertical mounting ME7026_00 07/14
Open the catalog to page 11In the following figure see the wiring diagram with the available I/O. Table 3 TP1057 Power Supply USB A Ethernet Serial ouputs 24Vdc 15% 400mA 2.0 Bit rate: 100Mbit/sec RS485 full duplex (hardware configuration) Power supply 4.2.1. Isolation Device has no galvanic isolation between input, output and power supply. 4.2.2. System power supply TP1057 has a 24Vdc (-15% +20 %) according to the scheme in the figure. System is protected against reverse power supply. ME7026_00 07/14
Open the catalog to page 124.2.3. Fuse System has no internal fuse , so is suggested the use of an external 1A fuse for the panel power supply. Attention A wrong value for the power supply can cause a damage to the device
Open the catalog to page 134.3. ModBus wiring ModBus on TP1057 is a 4 wire RS485 serial line, on the M2 terminal board on pins: Table 4 Description Line + Tx Line - Tx Line + Rx Line - Rx Example of a wiring of a system composed by: TPLC005 MPNC020 MPNC030 TP1057
Open the catalog to page 145.1. USB TP1057 has an USB 2.0 host for: software update. data storage: datalogger. Connect USB peripherals as printers, mouse, etc. Specific connection of external peripherals are implemented on request. 5.2. Ethernet TP1057 has a 10/100Mbit/s ethernet port with autoconfiguration, with direct or inverse connection cable. TP1057, by ethernet, can be controlled by a personal computer, it is possible to control the I/O of TP1057 by means of a program on a PC. 6. HMI To set the TP1057 is necessary to develop a software in QT Creator based on QT libraries, custom-tailored on MECT operator...
Open the catalog to page 15All MECT SRL catalogs and technical brochures
-
TPAC1008
22 Pages
-
TPAC1007
14 Pages
-
TPAC1006
22 Pages
-
MPA-MPV M6
42 Pages
-
MPA386 M6
39 Pages
-
MPP P6
19 Pages
-
MPA-MPV P6
18 Pages
-
MP40 P6 Simple imput
16 Pages
-
MP40 P6 Multi input
17 Pages
-
MPX28
8 Pages
-
MPSN20
2 Pages
-
MPCV015
20 Pages
-
MPT390 M6
61 Pages
-
MPT91 M1
66 Pages
-
MPT90 M1
46 Pages
-
MPT60 M1
45 Pages
-
MPT100 M1
35 Pages
-
MPCIB396 P6
41 Pages
-
MPCIB20 M1
25 Pages
-
MPCT301 P6
53 Pages
-
MPCT300 P6
37 Pages
-
MPCT30 P6
36 Pages
-
MPCT20 M1
35 Pages
-
MP2200 M6
44 Pages
-
MP1200 P6
36 Pages
-
MPPV340 M6
40 Pages
-
MPO347 M6
40 Pages
-
MPP323 M6
42 Pages
-
MPPV010 P6
40 Pages
-
MP45 P6
18 Pages
-
MPM P6
34 Pages
-
MP30 P2
15 Pages
-
MP20 M1
35 Pages
-
MPNC030
12 Pages
-
TPLC005
28 Pages
-
MPNC020
13 Pages
-
MPNC010
25 Pages
-
TP1070
15 Pages