MPT100 M1
35Pages

{{requestButtons}}

Catalog excerpts

MPT100 M1 - 2

resistance or possible leakage currents. 1. OUTLINE DIMENSIONS (mm) Instrument with non removable terminals 48 3. When a shielded cable is used, it should be connected at one point only. 4. Pay attention to the line resistance; a high line resistance may cause measurement errors. Removable terminals Cold junction accuracy: 0.1°C/°C after a warm-up of 20 minutes. Input impedance: > 1 MΩ. Calibration: According to EN 60584-1. Power supply Note: For TC wiring use proper compensating cable preferable shielded. 2.3.2. Infrared Sensor Input 2 1 External resistance: 100Ω max., maximum error 25 µV....

Open the catalog to page 2
MPT100 M1 - 3

Pt 1000 input circuit: Current injection (15 µA). Maximum contact resistance: 100Ω. Logic inputs driven by 24 VDC Input impedance: > 1 MΩ for mV Input 500 kΩ for Volt Input. 0/4... 20 mA input wiring for passive transmitter using auxiliary pws Logic status 1: 6... 24 VDC; Logic status 0: 0... 3 VDC. Safety notes: – To avoid electrical shocks, connect power line at last. – For supply connections use No. 16 AWG or larger wires rated for at last 75°C. – Use copper conductors only. – SSR outputs are not isolated. A reinforced isolation must be assured by the external solid state relays. Input...

Open the catalog to page 3
MPT100 M1 - 4

Relay Output Logic level 0: Vout < 0.5 VDC Logic level 1: 12 V ± 20%, 15 mA max. The maximum line length is equal to 30 m. Interface type: Isolated (50 V) RS-485; Protocol type: Byte format: Relay Output Baud rate: Programmable between 1200... 38400 baud; RS-485 interface allows to connect up to 30 devices with one remote master unit. 2. The cable length must not exceed 1.5 km at 9600 baud. Voltage levels: According to EIA standard; Power Supply Logic level 0: Logic level 1: Note: The maximum line length is equal to 30 m. Supply Voltage: - 24 VAC/DC (±10%) - 100... 240 VAC/DC (±10%) Note:...

Open the catalog to page 4
MPT100 M1 - 5

3.1 TECHNICAL SPECIFICATION Case: Plastic, self-extinguishing degree: V-0 according to UL 94; Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1; Terminals protection: IP 20 according to EN 60070-1; Installation: Panel mounting; Terminal block:16 screw terminals (screw M3, for cables from 0.25... 2.5 mm2 or from AWG 22... AWG 14) with connection diagrams; Dimensions: 48 x 48 mm, depth 75.5 mm Panel cutout: 45 x 45 (-0... +0.5 mm) Weight: 180 g max.. Power supply: – 24 VAC/DC (±10% of the nominal value); – 100... 240 VAC/DC (±10%...

Open the catalog to page 5
MPT100 M1 - 6

4.1 INTRODUCTION When the instrument is powered, it starts immediately to work according to the parameters values loaded in its memory. The instrument behaviour and its performance are governed by the value of the stored parameters. At the rst start up the instrument will use a “default” parameter set (factory parameter set); this set is a generic one (e.g. a TC J input is programmed). We recommend to modify the parameter settings to suit your application (e.g.: input type, Control strategy, alarms, etc.) To change these parameters you need to enter the “Conguration mode”. 4.2 INSTRUMENT...

Open the catalog to page 6
MPT100 M1 - 7

4. Using and buttons set the code 1 value according to the following tables. Prepare your code 1 Input Type and Range TC J -50... +1000°C TC K -50... +1370°C TC S -50... 1760°C TC R -50... +1760°C TC T -70... +400°C Infrared J -50... +785°C Infrared K -50... +785°C PT 100/PTC KTY81-121 -200... +850°C/-55... +150°C PT 1000/NTC 103-AT2 -200... +850°C/-50... +110°C Linear 0... 60 mV Linear 12... 60 mV Linear 0... 20 mA (this selection forces Out 4 = TX) Linear 4... 20 mA (this selection forces Out 4 = TX) Linear 0... 5 V Linear 1... 5 V Linear 0... 10 V Linear 2... 10 V TC J -58... +1832°F TC...

Open the catalog to page 7
MPT100 M1 - 8

4.5 COMPLETE CONFIGURATION PROCEDURE. 4.8 FACTORY RESET - DEFAULT PARAMETERS LOADING PROCEDURE The conguration parameters are collected in various groups. Every group denes all parameters related with a specic function (e.g.: control, alarms, output functions). Sometime, e.g. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. button for more than 5 seconds. 1. Push the The upper display will show PASS...

Open the catalog to page 8
MPT100 M1 - 9

crAL TC K S TC S r TC R t TC T ir.J Exergen IRS J ir.cA Exergen IRS K Ptc PTC ntc NTC 0.60 0... 60 mV linear 12.60 12... 60 mV linear 0.20 0... 20 mA linear 4.20 4... 20 mA linear 0.5 0... 5 V linear 1.5 1... 5 V linear 0.10 0... 10 V linear 2.10 1... 10 V linear When a TC input is selected and a decimal gure is programmed (see the next parameter) the maximum displayed value becomes 999.9°C or 999.9°F. 2. Every change of the SEnS parameter setting will force the [2] dP = 0 and it will change all parameters related with dP (e.g. set points, proportional band, etc.). [2] dP - Decimal point...

Open the catalog to page 9
MPT100 M1 - 10

Hold of the measured value [status]. Stand by mode of the instrument [status] When the contact is closed the instrument operates in stand by mode. 5 Manual mode 6 HEAt with SP1 and CooL with “SP2” [status] (see “Note about digital inputs”) 7 Timer Run/Hold/Reset [transition] Short closure allows to start timer execution and to suspend it while a long closure (longer than 10 seconds) allows to reset the timer. 8 Timer Run [transition] a short closure allows to start timer execution. 9 Timer reset [transition] a short closure allows to reset timer count. 10 Timer run/hold [Status] - Contact...

Open the catalog to page 10
MPT100 M1 - 11

3. When [10] diF1 and [11] diF2 are equal to 20, the set point selection will be in accordance with the following table: Dig In1 4. When [10] diF1 is equal to 21, [11] diF2 setting is forced to up.du (21 value) and cannot perform another function. 5. When a “Sequential set point selection” is used (diF1 or diF2 = 18), every closure of of the logic input increase the value of SPAT (active set point) of one step. The selection is cyclic -> SP1 -> SP2 -> SP3 -> SP4 ] out Group - Output parameters [12] o1.t – Out 1 type Available: When the out 1 is a linear output Range: 0-20 = 0-20 mA 4-20 =...

Open the catalog to page 11

All MECT SRL catalogs and technical brochures

  1. TPAC1008

    22 Pages

  2. TPAC1007

    14 Pages

  3. TPAC1006

    22 Pages

  4. MPA-MPV M6

    42 Pages

  5. MPA386 M6

    39 Pages

  6. MPP P6

    19 Pages

  7. MPA-MPV P6

    18 Pages

  8. MPX28

    8 Pages

  9. MPSN20

    2 Pages

  10. MPCV015

    20 Pages

  11. MPT390 M6

    61 Pages

  12. MPT91 M1

    66 Pages

  13. MPT90 M1

    46 Pages

  14. MPT60 M1

    45 Pages

  15. MPCIB396 P6

    41 Pages

  16. MPCIB20 M1

    25 Pages

  17. MPCT301 P6

    53 Pages

  18. MPCT300 P6

    37 Pages

  19. MPCT30 P6

    36 Pages

  20. MPCT20 M1

    35 Pages

  21. MP2200 M6

    44 Pages

  22. MP1200 P6

    36 Pages

  23. MPPV340 M6

    40 Pages

  24. MPO347 M6

    40 Pages

  25. MPP323 M6

    42 Pages

  26. MPPV010 P6

    40 Pages

  27. MP45 P6

    18 Pages

  28. MPM P6

    34 Pages

  29. MP30 P2

    15 Pages

  30. MP20 M1

    35 Pages

  31. MPNC030

    12 Pages

  32. TPLC005

    28 Pages

  33. MPNC020

    13 Pages

  34. MPNC010

    25 Pages

  35. TP1070

    15 Pages

  36. TP1057

    15 Pages