Catalog excerpts
resistance or possible leakage currents. 1. OUTLINE DIMENSIONS (mm) Instrument with non removable terminals 48 3. When a shielded cable is used, it should be connected at one point only. 4. Pay attention to the line resistance; a high line resistance may cause measurement errors. Removable terminals Cold junction accuracy: 0.1°C/°C after a warm-up of 20 minutes. Input impedance: > 1 MΩ. Calibration: According to EN 60584-1. Power supply Note: For TC wiring use proper compensating cable preferable shielded. 2.3.2. Infrared Sensor Input 2 1 External resistance: 100Ω max., maximum error 25 µV....
Open the catalog to page 2Pt 1000 input circuit: Current injection (15 µA). Maximum contact resistance: 100Ω. Logic inputs driven by 24 VDC Input impedance: > 1 MΩ for mV Input 500 kΩ for Volt Input. 0/4... 20 mA input wiring for passive transmitter using auxiliary pws Logic status 1: 6... 24 VDC; Logic status 0: 0... 3 VDC. Safety notes: – To avoid electrical shocks, connect power line at last. – For supply connections use No. 16 AWG or larger wires rated for at last 75°C. – Use copper conductors only. – SSR outputs are not isolated. A reinforced isolation must be assured by the external solid state relays. Input...
Open the catalog to page 3Relay Output Logic level 0: Vout < 0.5 VDC Logic level 1: 12 V ± 20%, 15 mA max. The maximum line length is equal to 30 m. Interface type: Isolated (50 V) RS-485; Protocol type: Byte format: Relay Output Baud rate: Programmable between 1200... 38400 baud; RS-485 interface allows to connect up to 30 devices with one remote master unit. 2. The cable length must not exceed 1.5 km at 9600 baud. Voltage levels: According to EIA standard; Power Supply Logic level 0: Logic level 1: Note: The maximum line length is equal to 30 m. Supply Voltage: - 24 VAC/DC (±10%) - 100... 240 VAC/DC (±10%) Note:...
Open the catalog to page 43.1 TECHNICAL SPECIFICATION Case: Plastic, self-extinguishing degree: V-0 according to UL 94; Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1; Terminals protection: IP 20 according to EN 60070-1; Installation: Panel mounting; Terminal block:16 screw terminals (screw M3, for cables from 0.25... 2.5 mm2 or from AWG 22... AWG 14) with connection diagrams; Dimensions: 48 x 48 mm, depth 75.5 mm Panel cutout: 45 x 45 (-0... +0.5 mm) Weight: 180 g max.. Power supply: – 24 VAC/DC (±10% of the nominal value); – 100... 240 VAC/DC (±10%...
Open the catalog to page 54.1 INTRODUCTION When the instrument is powered, it starts immediately to work according to the parameters values loaded in its memory. The instrument behaviour and its performance are governed by the value of the stored parameters. At the rst start up the instrument will use a “default” parameter set (factory parameter set); this set is a generic one (e.g. a TC J input is programmed). We recommend to modify the parameter settings to suit your application (e.g.: input type, Control strategy, alarms, etc.) To change these parameters you need to enter the “Conguration mode”. 4.2 INSTRUMENT...
Open the catalog to page 64. Using and buttons set the code 1 value according to the following tables. Prepare your code 1 Input Type and Range TC J -50... +1000°C TC K -50... +1370°C TC S -50... 1760°C TC R -50... +1760°C TC T -70... +400°C Infrared J -50... +785°C Infrared K -50... +785°C PT 100/PTC KTY81-121 -200... +850°C/-55... +150°C PT 1000/NTC 103-AT2 -200... +850°C/-50... +110°C Linear 0... 60 mV Linear 12... 60 mV Linear 0... 20 mA (this selection forces Out 4 = TX) Linear 4... 20 mA (this selection forces Out 4 = TX) Linear 0... 5 V Linear 1... 5 V Linear 0... 10 V Linear 2... 10 V TC J -58... +1832°F TC...
Open the catalog to page 74.5 COMPLETE CONFIGURATION PROCEDURE. 4.8 FACTORY RESET - DEFAULT PARAMETERS LOADING PROCEDURE The conguration parameters are collected in various groups. Every group denes all parameters related with a specic function (e.g.: control, alarms, output functions). Sometime, e.g. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. button for more than 5 seconds. 1. Push the The upper display will show PASS...
Open the catalog to page 8crAL TC K S TC S r TC R t TC T ir.J Exergen IRS J ir.cA Exergen IRS K Ptc PTC ntc NTC 0.60 0... 60 mV linear 12.60 12... 60 mV linear 0.20 0... 20 mA linear 4.20 4... 20 mA linear 0.5 0... 5 V linear 1.5 1... 5 V linear 0.10 0... 10 V linear 2.10 1... 10 V linear When a TC input is selected and a decimal gure is programmed (see the next parameter) the maximum displayed value becomes 999.9°C or 999.9°F. 2. Every change of the SEnS parameter setting will force the [2] dP = 0 and it will change all parameters related with dP (e.g. set points, proportional band, etc.). [2] dP - Decimal point...
Open the catalog to page 9Hold of the measured value [status]. Stand by mode of the instrument [status] When the contact is closed the instrument operates in stand by mode. 5 Manual mode 6 HEAt with SP1 and CooL with “SP2” [status] (see “Note about digital inputs”) 7 Timer Run/Hold/Reset [transition] Short closure allows to start timer execution and to suspend it while a long closure (longer than 10 seconds) allows to reset the timer. 8 Timer Run [transition] a short closure allows to start timer execution. 9 Timer reset [transition] a short closure allows to reset timer count. 10 Timer run/hold [Status] - Contact...
Open the catalog to page 103. When [10] diF1 and [11] diF2 are equal to 20, the set point selection will be in accordance with the following table: Dig In1 4. When [10] diF1 is equal to 21, [11] diF2 setting is forced to up.du (21 value) and cannot perform another function. 5. When a “Sequential set point selection” is used (diF1 or diF2 = 18), every closure of of the logic input increase the value of SPAT (active set point) of one step. The selection is cyclic -> SP1 -> SP2 -> SP3 -> SP4 ] out Group - Output parameters [12] o1.t – Out 1 type Available: When the out 1 is a linear output Range: 0-20 = 0-20 mA 4-20 =...
Open the catalog to page 11All MECT SRL catalogs and technical brochures
-
TPAC1008
22 Pages
-
TPAC1007
14 Pages
-
TPAC1006
22 Pages
-
MPA-MPV M6
42 Pages
-
MPA386 M6
39 Pages
-
MPP P6
19 Pages
-
MPA-MPV P6
18 Pages
-
MP40 P6 Simple imput
16 Pages
-
MP40 P6 Multi input
17 Pages
-
MPX28
8 Pages
-
MPSN20
2 Pages
-
MPCV015
20 Pages
-
MPT390 M6
61 Pages
-
MPT91 M1
66 Pages
-
MPT90 M1
46 Pages
-
MPT60 M1
45 Pages
-
MPCIB396 P6
41 Pages
-
MPCIB20 M1
25 Pages
-
MPCT301 P6
53 Pages
-
MPCT300 P6
37 Pages
-
MPCT30 P6
36 Pages
-
MPCT20 M1
35 Pages
-
MP2200 M6
44 Pages
-
MP1200 P6
36 Pages
-
MPPV340 M6
40 Pages
-
MPO347 M6
40 Pages
-
MPP323 M6
42 Pages
-
MPPV010 P6
40 Pages
-
MP45 P6
18 Pages
-
MPM P6
34 Pages
-
MP30 P2
15 Pages
-
MP20 M1
35 Pages
-
MPNC030
12 Pages
-
TPLC005
28 Pages
-
MPNC020
13 Pages
-
MPNC010
25 Pages
-
TP1070
15 Pages
-
TP1057
15 Pages