MPP323 M6
42Pages

{{requestButtons}}

Catalog excerpts

MPP323 M6 - 3

INDEX INDEX ------------------------------------------------------------------------------------------- 3 1.0 IN GENERAL ----------------------------------------------------------------------- 5 1.1 TECHNICAL CHARACTERISTICS------------------------------------------------- 5 1.2 DISPLAY SIGNALS-------------------------------------------------------------------- 5 1.3 WIRING DESCRIPTION -------------------------------------------------------------- 6 1.4 CONNECTION DIAGRAM POTENTIOMETER INPUT------------------------ 7 1.5 CONNECTION DIAGRAM 2 RELAY + SERIAL OUTPUT -------------------- 8 1.6...

Open the catalog to page 3
MPP323 M6 - 4

mect s.r.l. 7.2 DATA READING FROM HOST TO INSTRUMENT MPP M6 ----------------34 7.3 DATA TRANSMISSION FROM MPP M6 TO HOST---------------------------35 7.4 DATA WRITING FROM HOST TO MPP M6-------------------------------------36 7.5 COMMAND CODES ------------------------------------------------------------------37 7.6 TRANSMISSION OF HEXADECIMAL VALUES -------------------------------38 7.7 ALARM SETTING---------------------------------------------------------------------39 7.8 PEAK-HOLD RESET------------------------------------------------------------------39 7.9 GENERIC STATUS WORD...

Open the catalog to page 4
MPP323 M6 - 5

1.0 IN GENERAL The MPP model (use the potentiometer tranducer ) is instrument with a 16 bit analogue to digital converter; it is made in 48x96 standard body. The MPP model have interesting features as: • 4 ½ digit display ( ± 19999 digits ); • set-up of any reading value with any input value in the requested range; • maximum or minimum peak-hold; • programmable digital filter; • display reset function. The MPP instruments can be requested with the following options: • mono-directional or bi-directional (RS232 or RS485) standard or opto-isolated serial output • up to 4 relay alarms or up to...

Open the catalog to page 5
MPP323 M6 - 6

FSI=ISI ( same values of the input ) FSO=ISO ( same values of the output ) FS=IS (same values of the anal. output ) FS FSI ( wrong parameters of the input) serial output transmission buffer full (switch off and on the instrument to reset the error) serial output receiver buffer full (switch off and on the instrument to reset the error) fatal error: call assistance Exit Reset KEYBOARD DESCRIPTION AL Exit Reset : alarm set-up : allows readout zeroing, or, when in menu program, fast exit. : increments blinking digit in menu or decimal point set-up : shifts blinking digit in menu or prints...

Open the catalog to page 6
MPP323 M6 - 7

TERMINAL BOARD DESCRIPTION - analogue reference - signal input - power supply for transducer ( 2,5V) - analogue outputs (if requested) - Hold : short-circuiting terminals 10/12 stores observed - Display reset. Terminals 11/12 open: the reading are the same as the programming values. Terminals 11/12 closed: at the moment the terminals are short-circuited the display becomes zeroed (display reset) -instrument power supply 1.4 CONNECTION DIAGRAM POTENTIOMETER INPUT

Open the catalog to page 7
MPP323 M6 - 8

1.5 CONNECTION DIAGRAM2 RELAY + SERIAL OUTPUT EXCHANGE RELAY: 1.6 CONNECTION DIAGRAM - 4 RELA Y zzUlzzU zzUl

Open the catalog to page 8
MPP323 M6 - 9

1.7 CONNECTIONS FOR 8 STANDARD OR OPTO-ISOLATED STATIC Static output can be requested as follows (with order code): 1) STN/STNO: Standard or opto-isolated static NPN output open collector 2) STP/STPO: Standard or opto-isolated static PNP output open collector

Open the catalog to page 9
MPP323 M6 - 10

• Press + keys to enter menu. • To reach a menu item, use the and the dp key as shown in the menu flow for base instrument and base + option instrument. • To change a digit, use the 4p' key to increment the blinking digit and the key to shift the blinking digit and confirm by key. • To select an item use the key and confirm by the key. • To exit menu, use the PJpJ key: the modified parameters are stored.

Open the catalog to page 10
MPP323 M6 - 11

1.9 BASE INSTRUMENT MENU FLOW see "front keys enabling" see "Reading with 10 steps"

Open the catalog to page 11
MPP323 M6 - 12

1.10 OPTIONS INSTRUMENT MENU FLOW

Open the catalog to page 12
MPP323 M6 - 13

2.0 INSTALLATION NOTES 2.1 SIMPLIFIED INSTALLATION PROCEDURE 1- Connect the instrument as follows: pag 6 – base instrument wiring diagram pag 7 – input signal wiring diagram pag 8 – alarm wiring diagram (if requested). 2- Power up the instrument 3- Front panel keys allow the following set up: Zero key it is possible to set up the readout at the beginning of the • With input scale (minimum potentiometer). F.S. key it is possible to set up the readout at the end of the input • With scale (maximum potentiometer). To set up the zero and full scale values use the relevant keys, then use the d.p....

Open the catalog to page 13
MPP323 M6 - 14

appears on NOTES display AL 1 AL 2 Alarm 2 SP 1 First set-point of the alarm 2 0 0000 Input the value of alarm 2 ** (confirm with “FS ↵”) SP 1 SP 2 Second set-point of alarm 2, if request window alarms Read out Exit Reset ** to modify the value see the procedure illustrated in the paragraph “SET-UPS” . • To lock the front keys or to use other configuration, see the “ Front key enabling” paragraph • The instrument is ready to be used • To use the instrument with the “display reset” function, see "display clear function" paragraph • Other functions can be programmed following the paragraph...

Open the catalog to page 14
MPP323 M6 - 15

Table 4 appears NOTE seq. n° Press key on display PASS 1 FS ↵ + Press the “FS ↵” + “AL” keys AL 0 0000 Input the personal Password 2 FS ↵ ** (confirm with “FS ↵”) Ou 3 InP 4 5 FIL FILTER PROGRAMMING 5 FS ↵ tAr 6 5 ISI BEGINNING OF INPUT SCALE 7 5 POTENTIOMETER 0 0000 Insert the input value with which should represent the 8 FS ↵ initial scale reading. **(confirm with “FS ↵”) ISI 9 10 11 FSL tAr OFFS 00.000 OFFS PICC P.OFF BEGINNING OF READING SCALE (“ZERO” key ) Write the value you want to visualize with ISI. The same value is available with the “ZERO” front key. **(confirm with “FS ↵”) END...

Open the catalog to page 15
MPP323 M6 - 16

NOTE P.h.O. = Maximum peak with programmable reset time P.h.I. = Maximum infinite peak P.L.O. = Minimum peak with programmable reset time P.L.I. = Minimum infinite peak Press 5 key until you will see the req. item (confirm with " FS ↵") TIME OF PEAK RETENTION write retention time (0 ÷ 19.9 s) if PhO or PLO selected **(confirm with “FS ↵”) MEMORIZING DISPLAY CLEAR FUNCTION On = memorize the display clear function at the switching off OFF = the instrument looses the display clear function value at the switching off Press “5” key until you will see the req. item **(confirm with " FS ↵") Power...

Open the catalog to page 16

All MECT SRL catalogs and technical brochures

  1. TPAC1008

    22 Pages

  2. TPAC1007

    14 Pages

  3. TPAC1006

    22 Pages

  4. MPA-MPV M6

    42 Pages

  5. MPA386 M6

    39 Pages

  6. MPP P6

    19 Pages

  7. MPA-MPV P6

    18 Pages

  8. MPX28

    8 Pages

  9. MPSN20

    2 Pages

  10. MPCV015

    20 Pages

  11. MPT390 M6

    61 Pages

  12. MPT91 M1

    66 Pages

  13. MPT90 M1

    46 Pages

  14. MPT60 M1

    45 Pages

  15. MPT100 M1

    35 Pages

  16. MPCIB396 P6

    41 Pages

  17. MPCIB20 M1

    25 Pages

  18. MPCT301 P6

    53 Pages

  19. MPCT300 P6

    37 Pages

  20. MPCT30 P6

    36 Pages

  21. MPCT20 M1

    35 Pages

  22. MP2200 M6

    44 Pages

  23. MP1200 P6

    36 Pages

  24. MPPV340 M6

    40 Pages

  25. MPO347 M6

    40 Pages

  26. MPPV010 P6

    40 Pages

  27. MP45 P6

    18 Pages

  28. MPM P6

    34 Pages

  29. MP30 P2

    15 Pages

  30. MP20 M1

    35 Pages

  31. MPNC030

    12 Pages

  32. TPLC005

    28 Pages

  33. MPNC020

    13 Pages

  34. MPNC010

    25 Pages

  35. TP1070

    15 Pages

  36. TP1057

    15 Pages