Catalog excerpts
USER'S MANUAL
Open the catalog to page 11.0 Introduction To ensure fast installation and commissioning of described devices, we recommend that you carefully read the information in this manual. 1.1 Personnel Qualification The products described in this manual are for use only by personnel with experience in PLC programming, or technical specialist in the use of an electrical-driven automation. MECT Srl is not liable for failures caused by improper usage and damage to MECT devices or other devices, due to the non-compliance to the instructions contained in this manual. MECT Srl offers technical assistance through its technical...
Open the catalog to page 41.4 Security Attention Power down devices before any operation. Attention MPNC030 must be installed in closets or cabinets accessible only by qualified personnel through a key or a tool. ESD (Electrostatic Discharge) The modules contain electronic components that can be destroyed by electrostatic discharge. Every time you handle the modules, be sure that you and the system are connected to ground. The device does not have an ON-OFF switch and an internal fuse. Power up occurs immediately after applying the correct voltage (please check the power source voltage indicated on the nameplate of...
Open the catalog to page 5Mechanic Material Polycarbonate, Polyamide 6.6 Dimensions W x H x L - Terminal - 22.5 mm x 108 mm x 115 mm Installation DIN 35 Climatic Environmental Condition Operative Temperature 0 °C ... 55 °C Storage Temperature -20 °C ... +85 °C Relative Humidity 5 % to 95 % without condensation Safe Electrical Isolation Air and creepage distance acc. to IEC 60664-1 Degree of Pollution 2 acc. o IEC 61131-2 Degree of Protection Degree of Protection IP 20 Electromagnetic Compatibility Immunity to interference for industrial areas acc. to EN 61000-6-2 (2001) Strength Evaluation Test Specification Test...
Open the catalog to page 6Immunity to interference for industrial areas acc. to EN 61000-6-3 (2001) Test Specification Limit Frequency Distance Values/IQPI Range EN 55022 (AC supply, 66 ... 56 dB 150 kHz ... 500 conducted) 56 dB (µV) 500 kHz ... 5 60 dB (µV) 5 MHz ... 30 EN 55022 (DC 40 ... 30 dB 150 kHz ... 500 supply/data, conducted) 30 dB (µA) 500 kHz ... 30 EN 55022 (radiated) 30 dB (µV/m) 30 MHz ... 230 10 m 37 dB (µV/m) 230 MHz ... 1 10 m MPNC030 01 0.8 W excluding power toward loads Resolution Precision Thermal Stability Input Impedance: 20 ohm Input Impedance: 1Mohm Attention Install devices in power panel...
Open the catalog to page 7Fig 1: Dimensions 2.3 Installation 2.3.1 Distances The system must be installed allowing enough space for heat transfer, installation and wiring. Avoiding wires overlapping also prevents electromagnetic compatibility problems. Fig 2: Spaces 2.3.2 Component Adding and Removal Attention Be sure that devices are not powered when performing component adding or removal. ME7016_04
Open the catalog to page 8MPNC030-01 mect srl 2.3.3 Assembly sequence The insertion and removal of a single terminal is made by using the hook at the base of the terminal as shown. The assembly must begin with the insertion of the coupler (MPNC010 or TPLC005). After that, the required terminal are inserted in sequence. The DIN rail mounting is ensured by the spring coupling each terminal. adding terminals removing terminals Fig 3: Terminal adding and removal The instruments must be assembled on TBUS as shown below. MPNC010 or TPLC005 must be positioned to the right and the nodes to the left.
Open the catalog to page 9MPNC030-01 mect srl 2.3.4 DIN Rail and TBUS All modules must be attached directly onto a DIN rail type EN 50022 (DIN 35) on which their TBUS connection modules were properly inserted. TBUS connection modules perform internal communication between the bus coupler and terminals. modular connector DIN rail modular connector TBUS connection 2.3.5 Wiring Description MPNC10 and nodes daisy chain connection 1 2 3 4
Open the catalog to page 10MPNC030-01 TPLC005 and nodes daisy chain connection verde green grigio gray giallo yellow nero black
Open the catalog to page 11Thermocoupling input connection
Open the catalog to page 12All MECT SRL catalogs and technical brochures
-
TPAC1008
22 Pages
-
TPAC1007
14 Pages
-
TPAC1006
22 Pages
-
MPA-MPV M6
42 Pages
-
MPA386 M6
39 Pages
-
MPP P6
19 Pages
-
MPA-MPV P6
18 Pages
-
MP40 P6 Simple imput
16 Pages
-
MP40 P6 Multi input
17 Pages
-
MPX28
8 Pages
-
MPSN20
2 Pages
-
MPCV015
20 Pages
-
MPT390 M6
61 Pages
-
MPT91 M1
66 Pages
-
MPT90 M1
46 Pages
-
MPT60 M1
45 Pages
-
MPT100 M1
35 Pages
-
MPCIB396 P6
41 Pages
-
MPCIB20 M1
25 Pages
-
MPCT301 P6
53 Pages
-
MPCT300 P6
37 Pages
-
MPCT30 P6
36 Pages
-
MPCT20 M1
35 Pages
-
MP2200 M6
44 Pages
-
MP1200 P6
36 Pages
-
MPPV340 M6
40 Pages
-
MPO347 M6
40 Pages
-
MPP323 M6
42 Pages
-
MPPV010 P6
40 Pages
-
MP45 P6
18 Pages
-
MPM P6
34 Pages
-
MP30 P2
15 Pages
-
MP20 M1
35 Pages
-
TPLC005
28 Pages
-
MPNC020
13 Pages
-
MPNC010
25 Pages
-
TP1070
15 Pages
-
TP1057
15 Pages