Open the catalog to page 1INDEX INDEX ------------------------------------------------------------------------------------------- 3 1.0 IN GENERAL ----------------------------------------------------------------------- 5 1.1 TECHNICAL CHARACTERISTICS ------------------------------------------------- 5 1.2 DISPLAY SIGNALS-------------------------------------------------------------------- 6 1.3 WIRING DESCRIPTION -------------------------------------------------------------- 6 1.4 CONNECTION DIAGRAMS MP2200 SERIES ----------------------------------- 8 1.5 CONNECTION DIAGRAM 2 RELAY + SERIAL OUTPUT --------------------...
Open the catalog to page 3mect s.r.l. 7.4 DATA WRITING FROM HOST TO MP2200 M6 --------------------------------38 7.5 COMMAND CODES ------------------------------------------------------------------39 7.6 TRANSMISSION OF HEXADECIMAL VALUES -------------------------------40 7.7 ALARM SETTING---------------------------------------------------------------------41 7.8 PEAK-HOLD RESET------------------------------------------------------------------41 7.9 GENERIC STATUS WORD ----------------------------------------------------------42 7.10 BASIC PROGRAM -------------------------------------------------------------------42 8.0...
Open the catalog to page 41.0 IN GENERAL The MP2200 model is an instrument with a 16 bit analogue to digital converter they are made in 48x96 standard body. In just one instrument various inputs are combined in order facilitate “on line” readings from thermocouplings or from thermoresistences or signals coming from ammeter or voltmeter amplifiers. In particular the programmable inputs are as follows: thermocoupling input: Fe/CO ( 0÷600 °C ) thermocoupling input: Cr/Al ( 0÷1200 °C ) thermoresistance input: PT100 ( -40.0÷200.0 °C ) thermoresistance input: PT100 ( 0÷800 °C ) ammeter input: 0÷±20mA ( 0÷±20000 ) volmeter input:...
Open the catalog to page 5Dimensions Piercing template conv/sec 48 x 96 x 120 mm 44.5 mm (height) x 92.5 mm (width) 30 (without filter) instrument software version over-range signal under-range signal FSL=ISL ( same values of the reading ) FSI=ISI ( same values of the input ) FSO=ISO ( same values of the output ) FS=IS (same values of the anal. output ) FS FSI ( wrong parameters of the input) serial output transmission buffer full (switch off and on the instrument to reset the error) serial output receiver buffer full (switch off and on the instrument to reset the error) fatal error: call assistance Exit Reset KEYBOARD...
Open the catalog to page 6: readout zero set-up : readout full scale set-up or enter in menu (enter) + : readout ambient temperature (only for thermocoupling inputs) LEDS DESCRIPTION TERMINAL BOARD DESCRIPTION - analogue reference - measuring signal input - measuring current for thermoresistances - shunt resistance for current input - power supply for transducer ( V5-=-V24 option) - terminals for analogue outputs (if requested) - Hold : short-circuiting terminals 10/12 memorises observed value - Display reset. Terminals 11/12 open: the readings are the same as the programming values. Terminals 11/12 closed: at the moment...
Open the catalog to page 71.4 CONNECTION DIAGRAMS MP2200 SERIES Connection for current input Connection for voltage input Connections for thermocoupling input. Connections for input from PT100 2 Connections for input from PT100 3 Connections for input from PT100 4 Connections for input from transducer 2 Connections for input from transducer 3
Open the catalog to page 81.5 CONNECTION DIAGRAM 2 RELA Y + SERIAL OUTPUT 1.6 CONNECTION DIAGRAM - 4 RELA Y zzUlzzO zzOl
Open the catalog to page 91.7 CONNECTIONS FOR 8 STANDARD OR OPTO-ISOLATED STATIC Static output can be requested as follows (with order code): 1) STN/STNO: Standard or opto-isolated static NPN output open collector 2) STP/STPO: Standard or opto-isolated static PNP output open collector
Open the catalog to page 10Press + 1 I keys to enter menu. To reach a menu item, use the and the key as shown in the menu flow for base instrument and base + option instrument. To change a digit, use the H'p' key to increment the blinking digit and the IB key to shift the blinking digit and confirm by * ~ key. To select an item use the key and confirm by the key. To exit menu, use the key: me modified parameters are stored.
Open the catalog to page 111.9 BASE INSTRUMENT MENU FLOW see "front keys enabling" COFFj 0000 if temperature input
Open the catalog to page 121.10 OPTIONS INSTRUMENT MENU FLOW
Open the catalog to page 132.0 INSTALLATION NOTES 2.1 TEMPERATURE INPUTS The MP2200 can be used as a temperature reader using the thermocoupling or thermoresistance sensors. Connect the request probe following page 8 indications. Choose the correct input scale with "SCAL" menu item as shown in the table 4. Near input connections there is a temperature sensor for the cool junction compensation for thermocouple input. This temperature can be read by pressing the Exit Reset " " and " " keys (together) on the front panel. It is possible to correct the temperature readout by means of the "CoFF" menu item ( see table 4 ). It...
Open the catalog to page 14NOTES alarms exit Read out Reset ** to modify the number set-up see the procedure illustrated in the paragraph “SETUPS” . 12 2.2 CURRENT INPUTS The readings on the scale "0÷20mA" can be used by anyone who has a 2 or 3 wires transducer or a current output converter. The 0÷20 mA input scale is a bipolar scale with a ±19999 points maximum read out corresponding to a ±20mA input current or 20000 points maximum readout corresponding to 4÷20 mA input current. Connect the request probe following page 8 indications. Choose the correct input scale with "SCAL" menu item as shown in the table 4. It is than...
Open the catalog to page 15• To lock the front keys or for other configurations see the “ Front key enabling” • The instrument is ready to be used • To use the instrument with the “display reset” function see "display clear function" paragraph • Other functions can be programmed following the paragraph "Complete installation procedure " 2.3 VOLTAGE INPUT The readings on the scale "0÷10V" can be used by anyone who has a 3 or 4 wires transducer or a voltage output converter. The 0÷10V input scale is a bipolar scale with a ±19999 points maximum read out corresponding to a ±10V input voltage. Connect the request probe following...
Open the catalog to page 1622 Pages
14 Pages
22 Pages
42 Pages
39 Pages
19 Pages
18 Pages
16 Pages
17 Pages
8 Pages
2 Pages
20 Pages
61 Pages
66 Pages
46 Pages
45 Pages
35 Pages
41 Pages
25 Pages
53 Pages
37 Pages
36 Pages
35 Pages
36 Pages
40 Pages
40 Pages
42 Pages
40 Pages
18 Pages
34 Pages
15 Pages
35 Pages
12 Pages
28 Pages
13 Pages
25 Pages
15 Pages
15 Pages