Introduction Shipping, storage and product inspection Shipping and storage The device is to be safeguarded against dampness, dirt, impact and damage. Product inspection Upon receipt of the product, check the contents of the box and the product particulars against the information on the delivery slip and order form so as to ensure that all ordered components have been supplied. Notify us of any shipping damage immediately upon receipt of the product. Any damage claim received at a later time will not be honored. II. Your flowmeter was manufactured in accordance with the highest quality standards and was thoroughly tested prior to shipment. However, in the event any problem arises with your device, we will be happy to resolve the problem for you as quickly as possible under the terms of the warranty which can be found in the terms and conditions of delivery. Your warranty will only be honored if the device was installed and operated in accordance with the instructions for your device. Any mounting, commissioning and/or maintenance work is to be carried out by qualified and authorized technicians only. Application domain The mag-flux M1 is a microprocessor controlled and programmable transmitter that can be customized using control unit. Although basic configuration settings such as transmitter calibration are realized at the factory, other settings such as those for measurement data processing, analysis, display and output are user definable. Measurement data from sensors of series mag-flux are processed by the transmitter (hereinafter referred to as mag-flux M1). It can be installed directly on the sensor (compact version) or be mounted separately (remote version) and it is designed for flow velocities up to 10 m/s. A remote version is available for sensor mag-flux A, mag-flux S, mag-flux F5 and also for probes mag-flux MIS 1/D and mag-flux MIS 2/15. A compact version is only available for sensor mag-flux A and mag-flux S. III. Repair It is important that you do the following before shipping your flowmeter to MECON GmbH for repair: • Enclose a description of the problem with your device. Describe in as much detail as possible the application and the physical and chemical properties of the fluid. Remove any residues from the seal grooves and particularly important if carcinogenic, radioactive or The operator is liable for any substance removal or personal damage costs arising from inadequate cleaning of a device that is sent for repair. the device and be sure to clean recesses thoroughly. This is the fluid is corrosive, toxic, otherwise hazardous. IV. Using HART® hand-held terminal For information regarding operation of the transmitter using the HART hand-held terminal, see “Operation of the mag-flux M1 transmitter using the HART hand-held terminal.” The transmitter mag-flux M1 is communication enabled and supports optional the HART® protocol. Special features High-speed signal processing by 16-bit Microcontroller Easy multilingual menu navigation with a two-line display Steps prior to operation It is essential that these operating instructions have been read before installing and operating the device. The device has to be installed and serviced by a qualified technician only. The mag-flux M1 transmitter is solely suitable to measure volume flow of liquids in conjunction with a sensor of series mag-flux. Self-monitoring system Internal simulation for all output values Digital outputs (pulse, frequency, alarm, forward and reverse flow, MIN / MAX flow rate) User settings protected by user definable password Downloading of the present document from our web site www.mecon.de and printing out this document is allowed only for purposes of using our flowmeters. All rights reserved. No instructions, wiring diagrams, and/or supplied software, or any portion thereof, may be produced, stored, in a retrieval system or transmitted by any means, electronic, mechanical, photocopying or otherwise, without the prior written permission of MECON GmbH. Although the materials in the present document were prepared with extreme care, errors cannot be ruled out. Hence, neither the Mecon GmbH Röntgenstraße 105 D-50169 Kerpen

Open the catalog to page 1
mag-flux M1 - 2

company, the programmer nor the author can be held legally or otherwise responsible for any erroneous information and/or any loss or damage arising from the use of the information enclosed. MECON GmbH extends no express or implied warranty in regard to the applicability of the present document for any purpose other than that described. Installation and servicing The devices described in this manual are to be installed and serviced only by qualified technical personnel such as a qualified MECON GmbH electronics engineer or service technician. Warning! Before servicing the device, it must be...

Open the catalog to page 2
mag-flux M1 - 3

Caution means that failure to take the prescribed precautions could result light severe bodily injury or material damage! Caution! The complete unit has to be replaced with all of its printed boards (except for the memory chip (DSM)). The specified precision and interchangeability of the electronics are only guaranteed if the complete insert is replaced. Note means that the accompanying text includes important information about the product, handling the product or about a section of the documentation that is of particular importance. Manufacturer Warning! The operator is responsible for...

Open the catalog to page 3
mag-flux M1 - 4

Warning! According to EN 50178:1997 all electrical circuits with „protectiv safety isolation without any protection against contacts” must observe the following maximum voltages: • Maximum AC voltage (Veff) 25 V It is strictly forbidden to connect FE to any higher voltage! Startup conditions Operating principle and system design Measuring principle It was back in 1832 that Faraday suggested utilizing the principle of electrodynamic induction for measuring flow velocities. His experiments in the Thames, though unsuccessful due to superimposed polarization effects, are nonetheless regarded as...

Open the catalog to page 4

All MECON catalogs and technical brochures

  1. MENKAR KK

    28 Pages

  2. MENKAR

    28 Pages

  3. Turbo-Lux® 3

    20 Pages

  4. N4

    20 Pages

  5. Gardex

    5 Pages

  6. RE 250

    32 Pages

  7. Minix

    4 Pages

  8. Tubux M30

    20 Pages

  9. KBF

    20 Pages

  10. Trogflux

    21 Pages

  11. mag-flux F5

    4 Pages

  12. mag-flux A

    9 Pages