FVA Trogflux short version variable area flowmeter Operating Instructions © MECON GmbH 05/2013 OI_FVA_Trogflux_KBF_EN

Open the catalog to page 1
KBF - 2

All rights reserved. It is prohibited to reproduce this document, or any parts thereof, without prior written authorization of MECON Flow Control Systems GmbH. Subject to change without notice. Copyright 2013 by MECON Flow Control Systems GmbH - Röntgenstraße 105 - 50169 Kerpen Page 2 / 20 Operating instructions FVA Trogflux short version 05/2013 OI_FVA_Trogflux_KBF_EN

Open the catalog to page 2
KBF - 3

Operating instructions FVA Trogflux short version 05/2013 OI_FVA_Trogflux_KBF_EN

Open the catalog to page 3
KBF - 4

Safety Instructions 1 Safety Instructions 1.1 Intended use The FVA Trogflux short version variable area meters are used to measure the volume of transparent liquids and gases passing through closed piping. The variable area meters can also be used for flow monitoring if they are equipped with one or more switching contacts. Standard scales are available for liquids with a density of 1 kg/l (62.43 lb/cu.ft). The scales must be recalculated for all other media depending on the physical characteristics. The devices are particularly suitable fort he measurement of: • clear liquids gas flows...

Open the catalog to page 4
KBF - 5

Safety Instructions The manufacturer certifies for the device FVA Trogflux short version meets all statutory requirements of the following EC directives by applying the CE marking: • Pressure equipment directive 97/23/EC The most hazardous permissable media are − for gases: fluids of group 2 for liquids: fluids of group 1. 1.3 Safety instructions from the manufacturer Disclaimer The manufacturer will not be liable for any damage resulting from the use of its product, including, but not limited to direct, indirect, incidental, punitive and consequential damages. Any product purchased from...

Open the catalog to page 5
KBF - 6

Standard device When starting up the unit, the following points must be observed: ● Make sure that the actual operating conditions (pressure and temperature) do not exceed the limits specified on the nameplate. Avoid float float impact! Therefore it is recommended to start with a closed shut-off valve during commissioning and adjust the operating pressure by opening the valve slowly. In particular, the use of magnetic valves is not recommended in this case. When measuring liquids, make a careful release of the pipeline to prevent water hammer by gas bubbles. When commissioning new devices...

Open the catalog to page 6
KBF - 7

3 Installation 3.1 Installation instructions Information! All instruments are carefully checked for proper function before shipment. Check immediately on receipt, the outer packing carefully for damage or signs of improper handling. Report damage to the carrier and your competent sales staff. In such cases, a description of the defect, the type and the serial number of the device is indicated. Information! Unpack the unit carefully to avoid damage. Information! Check the completeness of the delivery against the packing list. Check the name plate, if the delivered flow meter according to...

Open the catalog to page 7
KBF - 8

4 Service 4.1 Storage Store the device dry and dust free. Avoid direct exposure to the sun and heat. Avoid external loads on the device. The admissible storage temperature for standard devices with electrical components: -40 … +70 °C. 4.2 Maintenance The devices are built for low maintenance operations but periodically the flowmeters should be inspected for signs of corrosion, mechanical wear as well as demage tot he fitting and the display unit. We advice to carry out inspections at least once a year. For a detailed inspection and cleaning the device must be removed from the piping....

Open the catalog to page 8
KBF - 9

Device description 5 Device description 5.1 Scope of delivery flowmeter FVA Trogflux short version Operating instructions Certificates (optional) Information ! Please check the delivery for completeness using the packing list. Standard device with PVC adhesive bushing The flowmeters FVA Trogflux short version exists in their main components from the plastic measuring tube with float and the connecting parts. The displayed directly on the scale on the flow tube (eg in l / h). A scale is printed on the flow tube (eg in l / h). The actual flowrate is read at the position of the largest...

Open the catalog to page 9
KBF - 10

Device description Special features • Product scales for liquids and gases Low cost plastic version Short delivery times for standard versions 5.3 Nameplate Important ! Please refer to the device nameplate to ensure that the device is built according to your order. Check particularly for the correct supply voltage. Code number Device specific code number Maximum temperature of the medium Maximum pressure of the medium Maximum pressure of the medium at temperature Tmax Operating instructions FVA Trogflux short version 05/2013 OI_FVA_Trogflux_K

Open the catalog to page 10
KBF - 11

Description Code 6 Description Code The descripion code consists oft he following elements: Gasket material Measuring cone size Float material Connection material Cast iron (only for G½, G1) Stainless steel Connection form Adhesive bushing (only in PVC) Female thread NPT (NPT ANSI B1.20.1) Operating instructions FVA Trogflux short version 05/2013 OI_FVA_Trogflux_KBF_EN

Open the catalog to page 11
KBF - 12

Device Description Connection size Adhesive bushing Contacts (only with magnetic floats) Without contact Contact K18/A (closes when below the limit) Contact K18/B (closes when exceeding the limit) Float version with magnet Other versions With calbration certificate Measured medium: always required, specify in plain text: Medium, Measuring range, Device range; Density; Viscosity, Device; Operating temperature, Operating pressure Silicone-free version Special version: specify in plain text Operating instructions FVA Trogflux short version 05/2013 OI_FVA_Trogflux

Open the catalog to page 12
KBF - 13

Measuring ranges for liquids 7 Measuring ranges for liquids Standard measuring range for liquids (ρ=1 kg/l, Viskosität 1mPa⋅s) ρ ⋅ Connection Measuring cone Maximum measuring range (for the selected float) Stainless steel Adhesive thread with magnet Pressure loss float with magnet Stainless steel Aluminium (connections in brackets are non Standard) Operating instructions FVA Trogflux short version 05/2013 OI_FVA_Trogflux_KBF_EN

Open the catalog to page 13

All MECON catalogs and technical brochures

  1. MENKAR KK

    28 Pages

  2. MENKAR

    28 Pages

  3. Turbo-Lux® 3

    20 Pages

  4. N4

    20 Pages

  5. Gardex

    5 Pages

  6. RE 250

    32 Pages

  7. Minix

    4 Pages

  8. Tubux M30

    20 Pages

  9. Trogflux

    21 Pages

  10. mag-flux M1

    35 Pages

  11. mag-flux F5

    4 Pages

  12. mag-flux A

    9 Pages