Flowmeter F I Gardex
1Pages

{{requestButtons}}

Catalog excerpts

Flowmeter F I Gardex - 1

The remote transmitter is an inductive absolute encoder. The pointer position of the F I Gardex is transmitted by a coupling fork to a rotatable magnet. Its orientation is detected by a programmable sensor with a resolution of 14 bit and supplied as an output signal from 4 to 20 mA. The angel transmitter will be delivered completely factory-adjusted, prewired and mounted. Fig.1 Remote transmitter for F I Gardex Technical specification Power consumption: < 0,2 W (load free output) Temperature correction value: Output signal: Load resistance: Operating temperature: Storage temperature: Electrical connection The prewiring of the angel transmitter to the plug-in connector is factory-set. For connection details of the plug-in connector please refer to the following wiring diagram: Mecon GmbH Röntgenstraße 105 D-50169 Kerpen Wiring diagramm for the remote transmitter