Thermal Probes Heaters-1

Guida Tecnica: Protezioni Termiche e Scaldiglie Anticondensa Technical Guide: Thermal Probes and Heaters

 Open the catalog to page 1
Thermal Probes Heaters-2

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1. THERMAL PROTECTIONS Upon the customer’s request it is possible to install one of the following devices as thermal protection. 1.1 PTC Thermistors These components are assembled in the heads of the stator windings and they control the maximum temperature. These devices do not measure the temperature of the windings, but a pre-set temperature limit of intervention. As a matter of fact, when the pre-set temperature is reached, the thermistors gives a signal that can be used by a trip device (not included in Mecc Alte supply)...

 Open the catalog to page 2
Thermal Probes Heaters-3

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1.3. Bimetallic thermal protections These devices usually have a NC (normally close) contact that trips immediately, when the operating temperature is reached. The contact resets automatically after a sensible drop in temperature. On specific customer’s request Mecc Alte can supply the following types of bimetallic thermal protections: a) b) c) d) e) f) g) S02.150.05 with NO (normally open) contact and operating temperature of 150°C. S06.100.05 with NC contact and operating temperature of 100°C. S06.120.05 with NC contact and...

 Open the catalog to page 3
Thermal Probes Heaters-4

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1. PROTEZIONI TERMICHE Su specifica richiesta del cliente è possibile prevedere una protezione termica utilizzando uno dei seguenti dispositivi. 1.1. Termistori PTC Questi componenti inseriti nelle testate degli avvolgimenti di statore ne sorvegliano la temperatura limite. Questi dispositivi non rilevano la temperatura degli avvolgimenti, ma una soglia limite di intervento. Infatti, raggiunta la temperatura prefissata, i termistori forniscono un segnale che può essere utilizzato da un dispositivo di sgancio (escluso dalla fornitura...

 Open the catalog to page 4
Thermal Probes Heaters-5

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1.3. Protettori termici bimetallici Questi dispositivi hanno di solito un contatto normalmente chiuso che scatta rapidamente quando viene raggiunta una determinata temperatura. Dopo una sensibile diminuzione della temperatura il contatto si ripristina automaticamente. Su richiesta Mecc Alte può fornire i seguenti protettori termici bimetallici: h) i) j) k) l) m) n) S02.150.05 con contatto normalmente aperto e temperatura di intervento di150°C. S06.100.05 con contatto normalmente chiuso e temperatura di intervento di100°C. S06.120.05...

 Open the catalog to page 5
Thermal Probes Heaters-6

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook IMAGE REFERENCE Picture n.1: Resistance /Temperature graph for one PTC Figura n.1 Grafico resistenza /temperatura per un PTC

 Open the catalog to page 6
Thermal Probes Heaters-7

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook COLORE DEI CAVI/CABLES COLOR Picture n. 3: In the temperature range from 40 C° deg to 200 C° it can be used the formula : Figura n.3: Nell'intervallo di temperature da 40 C° a 200 C° puo essere usata la seguente

 Open the catalog to page 7
Thermal Probes Heaters-8

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook Picture n.4: Wiring diagram for PT100 Disegno n.4: Diagramma connessioni per P100 1 BIMETALLIC PROTECT IONSxPHASE 2 BIMETALLIC PROTECT IONSxPHASE Picture n.5: Wiring diagram for bimetallic thermal protectors Disegno n.5: Diagramma connessioni per contattori termici bimetallici SCALD IQLIA LATO USCITA CAVI HEATER CABLE OUTLET SIDE 2 HEATERS MxWINDING HEAD 1 Picture n.6: Wiring diagram for anticondensation heaters Disegno n.6: Diagramma connessioni perscaldiglie anticondensa

 Open the catalog to page 8
Thermal Probes Heaters-9

THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook

 Open the catalog to page 9
Thermal Probes Heaters-10

Mecc Alte Espai Vicenza - ITALY Polig. Ind. LosValeros Mecc Alte International S.A. Mecc Alte (EE.) PTE LTD Z.E.La Gagnerie 19 Kian Teck Drive 16330 ST.Amant De Boixe Singapore 628836 [email protected] [email protected]

 Open the catalog to page 10

All Mecc Alte catalogs and technical brochures

  1. ECO40 C-TYPE

    2  Pages

  2. BTP3 2 pole

    3  Pages

  3. Eogen

    5  Pages

  4. Njorgen

    3  Pages

  5. ATO28 2 pole

    4  Pages

  6. HM1

    4  Pages

  7. Zanardi

    9  Pages

  8. Portable

    9  Pages

  9. Power products

    16  Pages

  10. Industrial

    28  Pages

  11. Corporate

    24  Pages

  12. T16F

    2  Pages

  13. TR1

    2  Pages

  14. LT3/2

    2  Pages

  15. ES20F

    1  Page

  16. ES16F

    1  Page

  17. Rating Book

    36  Pages

  18. ECO series

    13  Pages

  19. Portable series

    11  Pages

  20. Company Profile

    14  Pages

  21. S20F 2Poles

    2  Pages

  22. T20F 2Poles

    2  Pages

  23. T16F 2Poles

    2  Pages

  24. S16F 2Poles

    2  Pages

  25. S20W 2Poles

    2  Pages

  26. S16W 2Poles

    2  Pages

  27. S15W 2Poles

    2  Pages

  28. ECP 34 2Poles

    2  Pages

  29. ECO 31 2Poles

    2  Pages

  30. ECP 28 2Poles

    2  Pages

  31. ECP 3 2Poles

    2  Pages

  32. ECO 46 4Poles

    2  Pages

  33. ECO 43 4Poles

    2  Pages

  34. ECO 40 4Poles

    2  Pages

  35. ECO 38 4Poles

    2  Pages

  36. ECP 34 4Poles

    2  Pages

  37. ECO 32 4Poles

    2  Pages

  38. ECP 28 4Poles

    2  Pages

  39. ECP 3 4 Poles

    2  Pages

Archived catalogs

  1. 400 Hz

    4  Pages

  2. BTO3 4Poles

    4  Pages

  3. BTO3 2Poles

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.