Open the catalog to page 1THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1. THERMAL PROTECTIONS Upon the customer’s request it is possible to install one of the following devices as thermal protection. 1.1 PTC Thermistors These components are assembled in the heads of the stator windings and they control the maximum temperature. These devices do not measure the temperature of the windings, but a pre-set temperature limit of intervention. As a matter of fact, when the pre-set temperature is reached, the thermistors gives a signal that can be used by a trip device (not included in Mecc Alte...
Open the catalog to page 2THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1.3. Bimetallic thermal protections These devices usually have a NC (normally close) contact that trips immediately, when the operating temperature is reached. The contact resets automatically after a sensible drop in temperature. On specific customer’s request Mecc Alte can supply the following types of bimetallic thermal protections: a) b) c) d) e) f) g) S02.150.05 with NO (normally open) contact and operating temperature of 150°C. S06.100.05 with NC contact and operating temperature of 100°C. S06.120.05 with NC contact...
Open the catalog to page 3THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1. PROTEZIONI TERMICHE Su specifica richiesta del cliente è possibile prevedere una protezione termica utilizzando uno dei seguenti dispositivi. 1.1. Termistori PTC Questi componenti inseriti nelle testate degli avvolgimenti di statore ne sorvegliano la temperatura limite. Questi dispositivi non rilevano la temperatura degli avvolgimenti, ma una soglia limite di intervento. Infatti, raggiunta la temperatura prefissata, i termistori forniscono un segnale che può essere utilizzato da un dispositivo di sgancio (escluso dalla...
Open the catalog to page 4THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook 1.3. Protettori termici bimetallici Questi dispositivi hanno di solito un contatto normalmente chiuso che scatta rapidamente quando viene raggiunta una determinata temperatura. Dopo una sensibile diminuzione della temperatura il contatto si ripristina automaticamente. Su richiesta Mecc Alte può fornire i seguenti protettori termici bimetallici: h) i) j) k) l) m) n) S02.150.05 con contatto normalmente aperto e temperatura di intervento di150°C. S06.100.05 con contatto normalmente chiuso e temperatura di intervento di100°C....
Open the catalog to page 5THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook IMAGE REFERENCE Picture n.1: Resistance /Temperature graph for one PTC Figura n.1 Grafico resistenza /temperatura per un PTC
Open the catalog to page 6THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook COLORE DEI CAVI/CABLES COLOR Picture n. 3: In the temperature range from 40 C° deg to 200 C° it can be used the formula : Figura n.3: Nell'intervallo di temperature da 40 C° a 200 C° puo essere usata la seguente
Open the catalog to page 7THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook Picture n.4: Wiring diagram for PT100 Disegno n.4: Diagramma connessioni per P100 1 BIMETALLIC PROTECT IONSxPHASE 2 BIMETALLIC PROTECT IONSxPHASE Picture n.5: Wiring diagram for bimetallic thermal protectors Disegno n.5: Diagramma connessioni per contattori termici bimetallici SCALD IQLIA LATO USCITA CAVI HEATER CABLE OUTLET SIDE 2 HEATERS MxWINDING HEAD 1 Picture n.6: Wiring diagram for anticondensation heaters Disegno n.6: Diagramma connessioni perscaldiglie anticondensa
Open the catalog to page 8THERMAL PROTECTIONS AND ANTI CONDENSATION HEATERS Reference Handbook
Open the catalog to page 9Mecc Alte Espai Vicenza - ITALY Polig. Ind. LosValeros Mecc Alte International S.A. Mecc Alte (EE.) PTE LTD Z.E.La Gagnerie 19 Kian Teck Drive 16330 ST.Amant De Boixe Singapore 628836 aftersales@meccalte.fr aftersales@meccalte.com.sg
Open the catalog to page 10All Mecc Alte catalogs and technical brochures
-
ECO40 C-TYPE
2 Pages
-
BTP3 2 pole
3 Pages
-
Eogen
5 Pages
-
Njorgen
3 Pages
-
ATO28 2 pole
4 Pages
-
HM1
4 Pages
-
Zanardi
9 Pages
-
Portable
9 Pages
-
Power products
16 Pages
-
Industrial
28 Pages
-
Corporate
24 Pages
-
T16F
2 Pages
-
TR1
2 Pages
-
LT3/2
2 Pages
-
ES20F
1 Pages
-
ES16F
1 Pages
-
Rating Book
36 Pages
-
ECO series
13 Pages
-
Portable series
11 Pages
-
Shaft Stiffness
8 Pages
-
Insulation Protection System
8 Pages
-
Motor Starting Capability
58 Pages
-
Company Profile
14 Pages
-
S20F 2Poles
2 Pages
-
T20F 2Poles
2 Pages
-
T16F 2Poles
2 Pages
-
S16F 2Poles
2 Pages
-
S20W 2Poles
2 Pages
-
S16W 2Poles
2 Pages
-
S15W 2Poles
2 Pages
-
HCP 34 24 poles
2 Pages
-
HCP 34 20 poles
2 Pages
-
HCO 32 20 poles
2 Pages
-
HCP 3 14 poles
2 Pages
-
ECP 34 2Poles
2 Pages
-
ECO 31 2Poles
2 Pages
-
ECP 28 2Poles
2 Pages
-
ECP 3 2Poles
2 Pages
-
ECO 46 4Poles
2 Pages
-
ECO 43 4Poles
2 Pages
-
ECO 40 4Poles
2 Pages
-
ECO 38 4Poles
2 Pages
-
ECP 34 4Poles
2 Pages
-
ECO 32 4Poles
2 Pages
-
ECP 28 4Poles
2 Pages
-
ECP 3 4 Poles
2 Pages
Archived catalogs
-
BTO3 2Poles
4 Pages
-
BTO3 4Poles
4 Pages
-
400 Hz
4 Pages