MEATEST Electromagnetic flowmeters pdf
12Pages

{{requestButtons}}

Catalog excerpts

MEATEST Electromagnetic flowmeters pdf - 1

ELECTROMAGNETIC FLOWMETERS for INDUSTRIAL APPLICATION

Open the catalog to page 1
MEATEST Electromagnetic flowmeters pdf - 2

Production line Multifunction Calibrators Software for automatic Calibration Camera Module One-phase and Three-phase Power/Energy Calibrator High Current AC/DC Calibrator Impedance Calibrator Resistance and Capacitance Programmable Boxes RTD Temperature Sensor Simulator Resistance Standards Temperature/Humidity Meter Precision Oil Bath Electromagnetic Flowmeters Company profile Czech company MEATEST was found in 1991. Profile of company includes development, manufacturing and sale of instruments especially for application in industry and in calibration laboratories. MEATEST is member of...

Open the catalog to page 2
MEATEST Electromagnetic flowmeters pdf - 3

Programmable Electromagnetic Flowmeter ••Sensor size 10 to 800 mm ••Compact and remote version with protection IP67, •• •• •• •• •• •• •• •• optionally IP68 (remote sensor) Mounting of electronic unit in two work planes Power supply voltage 115/230 VAC 50/60 Hz or 12, 24, 48 VDC Touch-less basic manual control with magnetic pointer Programmable datalogger and real time Remote control RS485, RS232 Programmable digital outputs, digital input, analog output 4-20mA Dosing feature using digital input Pipe and electronic self diagnostic ••Application ••Water and wastewater flowrate and total...

Open the catalog to page 3
MEATEST Electromagnetic flowmeters pdf - 4

Highly Accurate Electromagnetic Flowmeter Basic features like M-910 plus: ••Improved accuracy 0.25% ••Empty pipe detection ••Excitation coils temperature measuring ••Modbus communication protocol ••Power supply voltage 85 to 264 VAC (50/60 Hz) or 12, •• •• •• 24, 48 VDC Grounding electrode as standard Extended temperature range Alarm output Inductive flow meter M-920 is a device designed for measuring, indicating and storing volumetric flow and passed through volume data of conductive liquids. As there are neither moving nor mechanical parts in the flow profile the device can be applied to...

Open the catalog to page 4
MEATEST Electromagnetic flowmeters pdf - 5

Nominal size DN Nominal pressure PN Flow range Accuracy Ambient temperature Power supply Power consumption Liner Electrodes Measuring tube Flange Protection category Outputs Input Communication Displayed values Low-flow cutoff Time constant Empty pipe detection Temperature measurement Other features Conformity requirements M910/910E M920 M930 10 … 800 10 … 800 15 … 250 10, 16, 25, 40 10, 16, 25, 40 10, 16, 25, 40 0.1 to 10 m/s (0.01 to 5000 l/s) 0.03 to 12 m/s (0.003 to 6000 l/s) 0.1 to 10 m/s (0.02 to 500 l/s) 0.5 % in range 0.5 … 10 m/s 0.25% in range 0.5 … 12 m/s 0.5 % in range 0.5 … 10...

Open the catalog to page 5
MEATEST Electromagnetic flowmeters pdf - 6

Several types of sensors are offered with M-910, M-920 and M-930 Compact and remote version for different applications. While com- pact version is delivered with protection IP67, remote version sensor DIN or ANSI flanges according to standards EN1092-1 or ANSI B16.5 are delivered as standard. For special purpose different type of Sanitary flanges and PTFE liner according to DIN 11851 standard with typical application in food industry. Hard rubber or PTFE liner is manufactured. Maximal available dia- meter for hard rubber is 800 mm, for PTFE liner up to 300 mm. CrNi steel, Hastelloy or...

Open the catalog to page 6
MEATEST Electromagnetic flowmeters pdf - 7

Accessories & Options Earthing rings Principle of operation of electromagnetic flowmeter requires the working liquid to be conductive and grounded. To meet this condition in systems with plastic pipes Earthing rings can be ordered. The rings are inserted between sensor flange and flange of the pipe and electrically connected to ground. Extra cable for remote version Remote version is delivered with 6m long cable. The cables is removable both on sensor and transmitter side. Set of cables consist of two separated cables, one is applied for coil excitation, the second for electrodes sensing....

Open the catalog to page 7
MEATEST Electromagnetic flowmeters pdf - 8

Software Software Flow 920 Application software (included) Flow Features 920 Application software (included) • Save and recall instrument setting Features • Easy calibration • Service functions Save and • Password protection recall instrument setting • Connection via RS232 or RS485 Easy calibration • Windows 2000/XP/Vista/7 Service functions Password protection Connection via RS232 or RS485 Windows 2000/XP/Vista/7 Flow920 software is program for remote control of the flowmeter M-910/910E/920/930. With the program configuration and calibration of the transmitter can be performed easily....

Open the catalog to page 8
MEATEST Electromagnetic flowmeters pdf - 9

Precision RTD Simulator for heat meters calibration ••Adjustment, calibration and testing of heat meters, temperature controllers Resistance range from 16Ω to 10kΩ Simulation of Pt and Ni sensors Accuracy +/- 0.02 °C Temperature stability < 1ppm/°C 2, 3 and 4 wire connection Simulation of cable resistance Version M-612 with RS-232 M-612 GPIB RTD simulator is designed for testing and calibration of temperature controllers, thermometers and heat meters which use RTD resistance temperature sensor for sensing of temperature of working liquid. It can simulate wide range of frequently used Pt/Ni...

Open the catalog to page 9
MEATEST Electromagnetic flowmeters pdf - 10

Flowrate versus sensor diameter The choice of flowrate for an electromagnetic flowmeter depends on the diameter of the sensor. The higher pipe diameter, the higher flowrate can be measured. A determining parameter for flowrates is maximum velocity of the liquid. Maximum velocity is the speed, where the flow of liquid inside pipe is still laminar. In M910 it is limited to 10m/s (with 125% overload). Speed over 10 m/s is usually too high for industrial applications. Such diameter of pipe is usually selected, where expected flowrate is between Q5% and Q50%. In the table bellow applicable...

Open the catalog to page 10
MEATEST Electromagnetic flowmeters pdf - 11

Exhibitions MEATEST has been acting on the market in the field of calibration instruments for 19 years. MEATEST takes part in several exhibitions every year. Seminars Meatest organise seminars and training courses for customers to help them to get the most out of their investment in calibration instruments and software. Production For completing and testing MEATEST use its own production line and calibration laboratory. Final calibration is performed in laboratory with traceability to the Czech national standards. Brno – town in centre of Europe Brno, capitol of Moravia region is place of...

Open the catalog to page 11

All Meatest spol. s r.o. catalogs and technical brochures

  1. Calibrators

    1 Pages

  2. 9010

    6 Pages

Archived catalogs