Catalog excerpts
DC Voltage up to 100.0000 V, 20 ppm DC Current up to 50.0000 mA, 50 ppm Reference temperature range 13–33 °C Resistance, frequency, RTD TC simulation R, S, B, J, T, E, K, N, M, C, D, G2 GPIB, USB, RS-232 and ethernet interface Precision DC calibrator M160 is a portable source of industrial process signals including DC voltage, DC current, thermocouple and RTD simulation, resistance and frequency. Unlike most of the other process calibrators, the M160 comes with exceptional 20 ppm accuracy over 20 °C -wide reference temperature range. All these features are combined with user friendly interface multi-interface remote control and robust design make this calibrator ideal for both calibration laboratories as well as industry professionals. Main parameters of both generated and measured signals are displayed on large LCD together with function-specific tooltip, providing auxiliary information like range, accuracy or load limit. Instrument can be connected to different ATE systems via RS232, USB, LAN or GPIB interface. M160 is sophisticated instrument with its own recalibration procedure. The procedure enables to correct any deviation without mechanical adjustment. Zelezna 3 | 619 00 Brno | Czech Republic | 420 543 250 886 | meatest@meatest.com | www.meatest.co
Open the catalog to page 1SPECIFICATION Specifications below describe 1-year absolute accuracy including long-term stability, linearity, load and line regulation and reference standard measurement uncertainty as well as ambient conditions within specified limits. GENERAL DATA Reference temperature: Operating temperature: Storage temperature: Remote control: Power supply: Dimensions: Weight: Ordering codes DC Voltage Ranges, resolution, 1 year accuracy [ppm of value + absolute offset] Range Maximal load DC Current Ranges, resolution, 1 year accuracy [ppm of value + absolute offset] Range Maximal load Ranges,...
Open the catalog to page 2Frequency meter accuracy Summary range: Frequency resolution: Accuracy: TC types: Resolution: Accuracy: R, S, B, J, T, E, K, N, M, C, D, G2 0.01 °C 0.1– 0.8 °C, see user’s manual for detailed specification 0.02 °C (option) RTD types: Resolution: Accuracy: Pt. Ni 0.01 °C 0.1 – 0.2 °C, see user’s manual for detailed specification Zelezna 3 | 619 00 Brno | Czech Republic | 420 543 250 886 | meatest@meatest.com | www.
Open the catalog to page 3All Meatest spol. s r.o. catalogs and technical brochures
-
0950 Current Coil
1 Pages
-
Electrical Calibration
40 Pages
-
Calibrators
1 Pages
-
M109R High Resistance Decade
2 Pages
-
9010+ Multifunction
6 Pages
-
M194 High Resistance Decade
2 Pages
-
M151 High Current Calibrator
3 Pages
-
151-25 Current Coil
1 Pages
-
M550 Impedance Calibrator
3 Pages
-
9010
6 Pages
Archived catalogs
-
140-50 Current Coil
1 Pages
-
MAGNETIC FLOW METERS
12 Pages
-
M191 High Resistance Decade
2 Pages
-
Company Overview
9 Pages