M133C Power & Energy Calibrator
4Pages

{{requestButtons}}

Catalog excerpts

M133C Power & Energy Calibrator - 1

Power & Energy Calibrator Power quality and energy functions Three and single phase versions Phase accuracy 0.01º, frequency range 15 – 1000 Hz AC power up to 3x 18 kVA, DC up to 25.2 kW Optical scanning head, built-in multimeter Floating current outputs for 3-wire power meters Current coil for clamp meters up to 2250 A M133C is electric AC/DC power and energy calibrator for calibration of power meters, power transducers, power quality analyzers and generally all kinds of power measuring devices. Full version of M133C calibrator can generate four types of power distortion: harmonic up to 50 products, interharmonic up to 5 kHz, amplitude modulation using symmetrical sine or square wave envelope and finally dip/swell amplitude modulation using custom square wave envelope. All the parameters including distortion can be set independently for each phase. M133C is more than just a sophisticated power source. Using built-in process multimeter, both transducer inputs and outputs can be handled by the M133C at the same time so you can calibrate it more easily, using no other calibration equipment. Floating current outputs can be connected directly with voltage outputs o allow for 3-wire power meter calibration. One calibrator, many applications – saving your time, space and costs. Zelezna 3 | 619 00 Brno | Czech Republic | 420 543 250 886 | meatest@meatest.com | www.meatest.c

Open the catalog to page 1
M133C Power & Energy Calibrator - 2

SPECIFICATION Specifications below describe 1-year absolute accuracy, including long-term stability, linearity, load and line regulation and reference standard measurement uncertainty as well as ambient conditions within specified limits. DC/AC Voltage Voltage range summary DC: 1 V – 280 V AC sine: 1 Vrms – 600 Vrms Internal ranges Frequency range and accuracy Frequency resolution Total harmonic distortion Ranges, resolution, 1 year accuracy [% of value + % of range] Range Maximum burden current *1 In 40 – 70 Hz AC / otherwise. Sum of all currents from three phases is limited to 400 mA....

Open the catalog to page 2
M133C Power & Energy Calibrator - 3

DC/AC Power & Energy Power range summary Total accuracy based on voltage, current, phase shift and energy period specifications. Phase shift accuracy (IX to UX and UX to U1) Energy period range and accuracy Total 1 year power accuracy in common applications [% of value] Set current Aircraft onboard power (115 V, 400 Hz) Ship onboard power (440 V, 60 Hz) Voltage from current Voltage range Amplitude accuracy Source impedance Harmonic distortion Harmonic product frequency range Interharmonic product frequency range Modulation (Flicker) Product amplitude accuracy Sine, squarevawe Modulation...

Open the catalog to page 3
M133C Power & Energy Calibrator - 4

Warm-up time Reference temperature Operating temperature GENERAL DATA Storage temperature Temperature coefficient 10 % of accuracy / °C outside TREF Power supply Power analyzer calibration (application) Clampmeter calibration with 151-25 Current Coil (application) Power transducer calibration (application) Zelezna 3 | 619 00 Brno | Czech Republic | 420 543 250 886 | meatest@meatest.com | www.m

Open the catalog to page 4