Product catalog summary
Highlights
  • Designed for calibration of insulation meters and megaohm meters.
  • Features four decades with a range from 1 MΩ to 12 GΩ.
  • Maximum working voltage is 5 kV DC.
  • Operates with an internal accumulator or power line adapter.
  • Includes RS232 serial interface for control.
Description

The High Resistance Decade Box, model M-109R, is intended for use in calibration laboratories and service centers. It is suitable for calibrating insulation meters and megaohm-meters, as well as testing or setting high resistance meters. The device uses high voltage relays with extremely high insulation resistance for switching resistance components. It features an indication of input terminal overload and can be controlled manually or remotely via RS232.

Specifications
  • Warm-up time: 1 hour.
  • Reference temperature: 23°C ± 5°C.
  • Reference humidity: 10 - 50%.
  • Power supply: Internal accumulator or 15V power line adapter (100-240V/50-60 Hz).
  • Dimensions: 390 x 128 x 310 mm.
  • Weight: 4 kg.
  • Interfaces: RS232.
Resistance Range Summary
  • Range: 1 MΩ – 12.221 GΩ.
  • Maximum voltage: 5 kV DC between terminals H-L, H-, L-.
  • Connection: Two-terminal, three-terminal (GUARD).
  • Type of terminals: High voltage terminals with ERTALYTE isolation.
  • Isolation resistance of relays: > 1015 Ω.
  • Surface resistance of ERTALYTE: > 1016 Ω.
  • Specific resistance of ERTALYTE: > 1016 Ωcm.
Ranges and Accuracy
RangeNominal Value AccuracyVoltage Coefficient [±ppm/V]Temperature Coefficient [±ppm/°C]Maximum Voltage [DCV/RMS]
1 MΩ - 11 MΩ0.1%1< 1001000 / 700
10 MΩ - 110 MΩ0.2%1< 1002500 / 1700
100 MΩ - 1.1 GΩ0.5%2< 1005000 / 3500
1 GΩ - 11 GΩ1.0%2< 1005000 / 3500

Note: In the voltage range 0-1kV and temperature range 18-28°C, total accuracy is determined by the basic accuracy of the nominal value. In the voltage range 1-5kV and outside the temperature range 18-28°C, total accuracy is influenced by the voltage and temperature coefficients.

See more

Catalog excerpts

M109R High Resistance Decade-1

High Resistance Decade Calibration of insulation meters and megaohm meters 4 decades Range 1 MΩ – 12 GΩ Maximum working voltage 5 kV DC Internal accumulator / power line adapter Serial interface RS232 control High resistance decade box is aimed for calibrating of insulation meters and megaohm-meters. It is suitable for calibration laboratories and service centers, where it can be used also for testing or setting of high resistance meters. High voltage relays with extremely high insulation resistance are used for switching of resistance components. M-109R is equipped with indication of input terminal overload. Instrument is supplied from accumulator or power line adapter. Control is possible manually or remotely via serial interface RS232 Zelezna 3 | 619 00 Brno | Czech Republic | +420 543 250 886 | [email protected] | www.meatest.

 Open the catalog to page 1
M109R High Resistance Decade-2

SPECIFICATION Specifications below describe 1-year absolute accuracy of this product including long-term stability, linearity, load and line regulation and reference standard measurement uncertainty as well as ambient conditions within specified limits. Reference temperature GENERAL DATA Reference humidity Internal accumulator, power line supply adapter 15V (100-240V/50-60 Hz) Range summary Maximum voltage Power supply Two-terminal, three-terminal (GUARD) High voltage terminals with ERTALYTE isolation Isolation resistance of relays Surface resistance of ERTALYTE Specific resistance of ERTALYTE...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.