ELECTRICAL CALIBRATION detailed specifications

Open the catalog to page 1
Electrical Calibration - 2

Multifunction Calibrators Power & Energy Calibrators Special Laboratory Instruments Programmable Decades Calibration Software COMPANY PROFILE Meatest company was founded in 1991 and first designs date back another decade. With almost 40 years of experience in electrical metrology we make calibration and measurement equipment with long lasting reliability, user-friendliness and high performance at the very top of our priorities. Development is focused on robust and flexible solutions matching everyone’s needs and making your work easier. Meatest developers account for full 25 % of Meatest...

Open the catalog to page 2
Electrical Calibration - 3

MULTIFUNCTION CALIBRATORS – Basic uncertainties 10 ppm and 35 ppm – AC/DC power, energy, resistance, capacitance, frequency, TC, RTD – 400 MHz and 1.1 GHz scope options available – High voltage resistance option for 1.5 kV insulation testers – Built-in process multimeter – Interface RS232, LAN, USB, GPIB Multifunction calibrators 9010+ and 9010 are designed as universal calibration tools for electrical calibration laboratories, covering most of their workload like multimeters clamp meters, ohm meters, power meters and power analyzers, energy meters, transducers, insulation testers, process...

Open the catalog to page 3
Electrical Calibration - 4

SPECIFICATION DC / AC Voltage Frequency accuracy and resolution Non-sine waveform types saw, triangle, square, truncated sin; 200 Vrms, 1 kHz max Non-sine amplitude uncertainty Voltage output modes passive 50Ω output up to 200 mVdc active output in all DC and AC ranges 9010 – Ranges, resolution, 1 year uncertainty [ppm of value + absolute] Range 9010+ – Ranges, 1 year uncertainty [ppm of value + absolute] Range Uncertainty in passive mode. Active mode uncertainty is 220 ppm + 20 μV and 45 ppm + 20μV respectively in 9010, 100 ppm + 10 µV and 15 ppm + 10 µV respectively in 9010+. *2 Frequency...

Open the catalog to page 4
Electrical Calibration - 5

DC / AC Current Frequency accuracy and resolution Non-sine waveform types saw, triangle, square, truncated sin; 2 A rms, 1 kHz max Non-sine amplitude uncertainty 9010 – Ranges, resolution, 1 year uncertainty [ppm of value + absolute] Range 9010+ – Ranges, resolution, 1 year uncertainty [ppm of value + absolute] Range *5 Accuracy not specified below 10 µA. *6 300s maximum continuous output time. 9010 and 9010+ Distortion and Load Characteristics Parameter *7 THD in bandwidth up to 100 kHz. *8 Additional uncertainty for compliance voltage above 0.5 Vrms . Voltage from current Amplitude...

Open the catalog to page 5
Electrical Calibration - 6

Resistance range summary 2W and 4W continuous range 2W and 4W fixed decadic standards 100 GΩ High Voltage Resistance (optional) Variable resistance mode ranges and 1 year uncertainty [ppm of value + absolute] 9010+ Continuous range mode Fixed resistance mode ranges and 1 year uncertainty [ppm of value + absolute] 9010+ Nominal standard value Capacitance range summary 2W continuous range 2W fixed decadic standards 9010 and 9010+ capacitance modes, 1 year uncertainty and frequency limits Continuous range mode

Open the catalog to page 6
Electrical Calibration - 7

RTD temperature standards Pt3850, Pt3851, Pt3916, Pt3926, Ni120, custom RTD R0 range TC cold junction compensation Manual or automatic with adapter 91 Voltage range Current range Frequency range Phase shift uncertainty AC/DC Power & Energy Thermocouple types Energy period uncertainty Additional features Harmonic distortion, voltage from current, current coil multiplication 9010 – Total 1 year uncertainty overview [% of value] Current range 9010+ – Total 1 year uncertainty overview [% of value] Current range Harmonic distortion (all AC functions) Fundamental harmonic uncertainty amplitude: ≥...

Open the catalog to page 7
Electrical Calibration - 8

9010 and 9010+ options overview Option 400 MHz sine & PWM, input impedance measurement 1.1 GHz sine, 400 MHz PWM, input impedance measurement Insulation testers, megohmmeters Resistance up to 100 GΩ, 1.5 kV, test signal measurement Transducers, process meters DCV, DCA, resistance, TC, RTD and frequency measurement HF mode amplitude range HF mode frequency range Harmonic distortion Amplitude uncertainty LF mode (DC, square wave) Frequency uncertainty Rise time Division ratio Frequency range Rise time Frequency range Duty cycle ratios Input impedance measurement Amplitude ranges TRIGGER mode...

Open the catalog to page 8
Electrical Calibration - 9

SC1 Frequency/Scope option (9010+ only) HF mode amplitude range 1.400 mVpk – 1.5000 Vpk up to 1 GHz 1.400 mVpk – 1.0000 Vpk above 1 GHz HF mode frequency range Harmonic distortion Amplitude uncertainty PULSE WIDTH and TIME MARKER modes Frequency range 0.1 Hz – 400 MHz square wave 400 – 1100 MHz sine Frequency uncertainty Amplitude ranges 50 mVpk , 100 mVpk , 500 mVpk , 1 Vpk Duty cycle ratios Rise time LF mode, TRIGGER mode and Input impedance measurement function specifications are the same as in SCO option. HVR High Voltage Resistance option Maximum test voltage Resistance uncertainty...

Open the catalog to page 9
Electrical Calibration - 10

PORTABLE MULTIFUNCTION CALIBRATOR – C / DC  voltage / current up to 1000 V / 20 A A – asic accuracy 60 ppm, cold junction compensation B – alibration of clamp meters up to 1000 A using 140-50 Current Coil C – on-sinusoidal waveforms, resistance, frequency, TC, RTD N – ixed standard resistors from 10 Ω to 100 MΩ F – GPIB and RS-232 interface – Compact dimensions, overall weight 11 kg M143/143i Multifunction calibrator is cost saving solution for calibration of meters of electric quantities up to 1000 V and 20 A. Basic accuracy of 60 ppm in DC voltage is more than enough for calibration of 3½...

Open the catalog to page 10
Electrical Calibration - 11

SPECIFICATION DC/AC Voltage Voltage range summary DC: 0 mV – 1000 V AC sine: 1 mV – 1000 V Non-sine: 1 mVpk – 10 Vpk Internal ranges Frequency range Sine <10 V: 20 Hz – 10 kHz Sine >10 V: 40 Hz – 1 kHz Non-sine <10 V: 20 Hz – 80 Hz Frequency accuracy and resolution Non-sine waveform types saw, triangle, square, truncated sin Non-sine amplitude accuracy Voltage accuracy Current accuracy % of value + % of range * 1  Limited to 40 Hz – 1 kHz, sine waveform only. * 2 20 A range in M143 model only.. Frequency range Frequency accuracy Waveform type GENERAL DATA Sensor types Waveform type Warm-up...