Multifunction Calibrator Multifunction calibrator 9010+ is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like multimeters, 6/4 digit DMMs, clamp meters, ohm meters, power meters and AC/DC voltage/current up to 1050V/30A Basic uncertainty 10 ppm AC/DC power, energy, resistance, capacitance, frequency, TC, RTD Scope option up to 1100 MHz High voltage resistance option for 1.5 kV insulation testers Built-in process multimeter Interface R$232, LAN, USB, GPIB meters, scopes and many others. High load capacity of both voltage (up to 50 MA) and current output allows for calibration of high-consumption analogue meters. Installed harmonic and non-harmonic shape signals allow for testing meter sensitivity to distorted signals by a signal with various crest factor. Advancing from previous M14x calibrator series, 9010+ can now calibrate even 11 GHz scopes, 6) digit DMMSs, 15 kV insulation testers and power meters. On the other hand we kept all the popular functions including complete transducer and external sensor calibration (strain gauge, pressure, torsion, strength, etc.) using built-in multimeter, automatic uncertainty calculation, remote control and easy recalibration. 9010+ calibrator can be fully integrated into commonly used calibration automation platforms. Unique camera readout module CamOCR, available in Meatest's SW package Caliber/WinQbase, allows for semi-automated calibrations of multimeters with no remote control interface. Zelezna 3 | 619 00 Brno | Czech Republic | 420 543 250 886 | meatest@meatest.com
Open the catalog to page 1SPECIFICATION Specifications below describe 1-year absolute uncertainty at a confidence interval of 95%, including long-term stability, linearity, load and line regulation and reference standard measurement uncertainty as well as ambient conditions within specified limits, GENERAL DATA warm-up time Reference temperature Operating temperature Storage temperature Temperature coefficient 10 % of accuracy / “C outside Teer Power supply DC/AC Voltage Voltage range summary AC sine: 1 mVaws - 1050 Veus Non-sine: 1 MVaus - 200 Veus Internal ranges Frequency accuracy and resolution Non-sine waveform...
Open the catalog to page 2DC/AC Current Current range summary AC Sine: 10.0000 pArws - 30.00000 Arms Non-sine: 100.0000 pAaus — 2.000000 Ars Internal ranges Frequency accuracy and resolution Non-sine waveform types saw, triangle, square, truncated sin; TkHz max. Non-sine amplitude uncertainty Ranges, resolution, 1 year uncertainty [ppm of value] 15 Hz-1kHz Distortion and Load Characteristics Parameter TED in bandwidth up t2 100 kHz Acditional urcartsinty for compliance Amplitude uncertainty Source impedance Applicable multiplier Frequency range Additional uncertainty Current coil (option 140-50) Voltage range...
Open the catalog to page 3Resistance range summary 2W and 4W fixed decadic standards 100 GQ High Voltage Resistance (optional) Basic resistance modes and 1year uncertainty [ppm of value + absolute] Continuous range mode Nominal standard value Capacitance range summary 2W continuous range 2W fixed decadic standards Capacitance modes, 1 year uncertainty and frequency limits fanaa Thermocouple types TC cold junction compensation Zelezna 3 | 619 00 Brno | Czech Republic | 420 543 Manual or automatic with adapter 91
Open the catalog to page 4Range summary power: voltage: frequency: time period: Total uncertainty based on voltage, current, phase shift and energy period specifications. Phase shift uncertainty Energy period uncertainty Additional features Harmonic distortion, voltage from current, current coil multiplication Total 1 year power accuracy in common applications [% of value] [I — Aircraft onboard power Ship onboard power Harmonic distortion frequency: phase shift: Frequency range Harmonic product amplitude range Harmonic product phase shift unc Multimeter option Measurement function cement adapta” (cormas as standare...
Open the catalog to page 5Frequency /Scope option HF mode (levelled sine) Amplitude range: Amplitude uncertainty LF mode (DC, square wave) High voltage range: PULSE WIDTH and TIME MARKER modes Frequency range: Frequency uncertainty: Amplitude ranges: Rise time: TRIGGER mode 50 mVek, 100 mVek, 500 MVex, 1 Vex Duty cycle ratios: Division ratio: Measurement accuracy: Rise time: Input impedance measurement Frequency range: Amplitude range: Frequency /Scope option HF mode (levelled sine) 1.400 mVpx - 1.0000 Vek above 1 GHz Freg. range : Amplitude uncertainty PULSE WIDTH and TIME MARKER modes square wave Amplitude ranges:...
Open the catalog to page 6All Meatest spol. s r.o. catalogs and technical brochures
-
0950 Current Coil
1 Pages
-
Electrical Calibration
40 Pages
-
Calibrators
1 Pages
-
M109R High Resistance Decade
2 Pages
-
M194 High Resistance Decade
2 Pages
-
M160 Precision DC Calibrator
3 Pages
-
M151 High Current Calibrator
3 Pages
-
151-25 Current Coil
1 Pages
-
M550 Impedance Calibrator
3 Pages
-
9010
6 Pages
Archived catalogs
-
140-50 Current Coil
1 Pages
-
MAGNETIC FLOW METERS
12 Pages
-
M191 High Resistance Decade
2 Pages
-
Company Overview
9 Pages