Catalog excerpts
MAS10 Signal Conditioner Features Excellent Linearity, High input impedance Compatible with most load cells, pressure sensors, torque transducers, displacement and other transducers with strain gauge outputs Selectable outputs of ±10V, 0/10V and ±5V Output of 4-20mA, concurrent with -10V to +10V Zero Suppression up to ±100% Options Broadband response -3dB at 5kHz (standard is 100Hz) Strain gauge option accepts Full-,Half- or Quarter-Bridge including 3 wire configuration, 120Ω or 350Ω Shunt Calibration Custom Setup and Configuration Applications Torque, Force and Load Cells Force/ Pressure Verification Systems Pressure Transducers Indicators, Recorders, Control Systems Level and Flow transducers Scales and Weighing Systems Strain Gage option for stress Analysis High Speed Data Collection Systems Description The standard MAS10 signal conditioner combines a regulated excitation power supply with low level amplifier providing both voltage and current outputs. The strain gauge option adds bridge completion for ¼ and ½ bridge inputs suitable for stress analysis. The MAS10 features high stability, suitable for most industrial and research applications. Excitation is regulated over a broad range for compatibility with miniature sensors as well as commonly available pressure, force, torque and acceleration transducers. Excitation current is sufficient to drive up to four 350Ω load cells in multi-load cell applications. All inputs and outputs are surge-protected for factory and field installations. Gain is set by links (7 combinations) plus continuous adjustment for best stability over the wide dynamic range of inputs and outputs provided by MAS10. Other available features are: Optional shunt calibration provides a quick check of integrity of the transducer, it’s wiring, and gain setting. Strain gauge option, adds bridge completion for ¼ and ½ including 3 wire quarter bridge configuration for both 120Ω (providing maximum 5V excitation for sensor) and 350Ω (providing 10V excitation for sensor) strain gauges. Most sensitive range has full scale of 600micro-strain (10V excitation). Custom set-up to customer requirement; specify input, output and excitation level at time of order for MeasureX laboratory calibration. MeasureX Pty Ltd U14, 42 Garden Boulevard, Melbourne VIC 3172, Australia Tel: +61 3 9558 2420 email: Sales@MeasureX.com.au Website: www.MeasureX.com.au
Open the catalog to page 1MAS10 Signal Conditioner Technical Specifications Supply voltage: 18 or 28V Power consumption: ≤ 2W Amplifier input range: 3mV to 100mV, 0.3mV/V (at 10VDC excitation) to 10mV/V Input impedance: ≥100MΩ Input CMRR: -100dB @ 50Hz Output range: 0-10V, ±5V, ±10V and 4-20mA Voltage output source impedance: <100 Ω Current loop compliance: up to 600Ω at nominal supply Linearity: 0.01% FS Excitation: 1.25V to 10V (110mA max) Excitation stability: 5ppm/°C Zero range: up to ±100% continuously adjustable Zero stability: < 25ppm of FS/°C Gain range: x 100 to x 3300 link selectable Span adjustment: In 7...
Open the catalog to page 2All MeasureX Pty Ltd catalogs and technical brochures
-
MRB23
2 Pages
-
MLA66
1 Pages
-
MLA27
2 Pages
-
MDP45
2 Pages
-
MDL41
2 Pages
-
MDM41
2 Pages
-
MDL42
2 Pages
-
MDD12
2 Pages
-
MDM42
2 Pages
-
MDM43
2 Pages
-
MDL48
2 Pages
-
MDP41
2 Pages
-
MDP42
2 Pages
-
MDP43
2 Pages
-
MDP44
2 Pages
-
MTP41
2 Pages
-
MTM41
2 Pages
-
MRA26
2 Pages
-
MRA25
2 Pages
-
MLR61
1 Pages
-
MLS66
1 Pages
-
MDL44
2 Pages
-
MLW66
1 Pages
-
MLW64
1 Pages
-
MLR62
1 Pages
-
MLT66
1 Pages
-
MLT61
1 Pages
-
MLQ61
1 Pages
-
MLD61
1 Pages
-
MRD24
2 Pages
-
MRD23
2 Pages
-
MRD21
2 Pages
-
MRA23
2 Pages
-
MRB21
2 Pages
-
MRC21
2 Pages
-
MRC22
2 Pages
-
MRH21
2 Pages
-
MRF21
2 Pages
-
MRF23
2 Pages
-
MRF24
2 Pages
-
MRD26
2 Pages
-
MRS21
2 Pages
-
MRL24
2 Pages
-
MRA21
2 Pages
-
MRA24
2 Pages
-
MRB20
2 Pages
-
MRO21
2 Pages
-
MRB28
2 Pages
-
MRL25
2 Pages
-
MDL43
2 Pages
-
MSM31
2 Pages
-
MRQ22
2 Pages
-
MRQ23
2 Pages