USB-500/600 series
11Pages

{{requestButtons}}

Catalog excerpts

USB-500/600 series - 1

MEASUREMENT COMPUTING. USB-500/600 SeriesStand-Alone, Low-Cost Data Loggers and Accessories Features • Stand-alone remote data loggers and portable logger assistant • Measure temperature, humidity, voltage, current, or event/state change • 1 or 2 channels • Low cost, small size • Battery powered • Start/stop logging directly from device on USB-600 Series loggers Software • Includes easy-to-use software to set sampling interval, alarms, start time, and other options • Easily display, graph, and save data in formats such as .csv to import into Microsoft® Excel® • Supported Operating Systems: Windows® 8/7/Vista®/XP, 32-/64-bit USB-500/600 Series data loggers offer low-cost, stand-alone data collection for temperature, humidity, voltage, current, or event/state change. Overview The USB-500/600 Series of stand-alone data loggers record several types of environmental readings. Users can easily set up the logging interval and start-time, log data, and then download the data over USB to the computer. Logged data can then be graphed, printed, and exported to Excel. Each data logger is powered by a long-life lithium battery which lasts for up to a full year. Several models are available with different measurement input types, sampling intervals, and amount of built-in memory. * Compatible with USB-525 Logger Assistant Measurement Computing

Open the catalog to page 1
USB-500/600 series - 2

MEASUREMENT COMPUTING™ USB-500/600 SeriesGeneral Information Analog Input One or two channels are available on USB-500/600 Series data loggers. Devices are available with temperature, thermocouple, humidity, voltage, current, or event inputs. Sampling Interval Loggers can be programmed with sampling intervals from 1 second to as long as 12 hours, depending on your data collection needs and the logger you are using. The logger stores the data and then uploads it to a computer through USB when collection is complete. Logger Start Modes Depending on the USB-500/600 Series logger being used,...

Open the catalog to page 2
USB-500/600 series - 3

USB-500/600 Series Software USB-500/600 Series Data Logger Software USB-525 Logger Assistant The ultra-portable USB-525 Logger Assistant allows the user to conveniently program compatible USB-500 model loggers and view the data on a high-resolution screen. Each USB-500/600 Series data logger includes an easy‑to‑use software application which allows users to configure the following settings: • sampling interval The USB-525 is compatible with the following temperature/humidity data loggers: • high/low alarm options • temperature scale Use the included software to download, display, and save...

Open the catalog to page 3
USB-500/600 series - 4

USB-501 Temperature Logger Temperature Measurementrange:-35 °Cto80°C (-31 °Fto 176°F) Internal resolution: 0.5 °C (1 °F) typ Accuracy (overall error): ±1 °C (±2 °F) typ Data Sampling Sampling intervals (software-selectable): 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Max temperature samples: 16,382 Units: °C or °F USB Specifications USB device type: USB 2.0 (full speed) Device compatibility: USB 1.1, USB 2.0 Power Power source: 1/2AA 3.6 V lithium battery Battery life: 3 years @ 25 °C and 1 min logging rate Environmental Moisture and dust protection: Protective cap...

Open the catalog to page 4
USB-500/600 series - 5

Thermocouple Logger Power source: 1/2AA 3.6 V lithium battery Battery life: 2 years at 25°C and 1 min logging rate Probe measurement range K-type thermocouple: –200 ˚C to 1350 ˚C (–328 ˚F to 2462 ˚F) J-type thermocouple: –200 ˚C to 1190 ˚C (–328 ˚F to 2174 ˚F) T-type thermocouple: –200 ˚C to 390 ˚C (–328 ˚F to 734 ˚F) Internal resolution: 0.5 ˚C (1 ˚F) typ Accuracy (overall error): ±1 ˚C (±2 ˚F) typ Operating temperature range: –10 ˚C to 40 ˚C (14 ˚F to 104 ˚F) The high-contrast LCD shows temperature data and information regarding the logger status. Temperature (˚C/˚F): Current temperature,...

Open the catalog to page 5
USB-500/600 series - 6

USB-502-LCD Temperature and Humidity Logger with LCD Temperature Measurement range: -35 °C to 80 °C (-31 °F to 176 °F) Accuracy (overall error)*: ±0.5 °C typ, max; ±1 °F typ, ±4 °F max Internal resolution: 0.5 °C, 1 °F typ Alarm threshold range (software-selecl -35 °C to 79.5 °C (-31 °F to 175 °F/ high and low alarms Relative Humidity (%RH) Measurement range: 0% to 100% Accuracy (overall error)*: 2.25% RH typical (20% RH to 80% RH) Internal resolution: 0.5% RH typ Long term stability: <0.25% RH/year Alarm threshold range: 0% to 99.5% (high and low alarms) Dew Point Accuracy (overall...

Open the catalog to page 6
USB-500/600 series - 7

MEASUREMENT COMPUTING. USB-502-PLUS Temperature and Humidity Logger with Increased Accuracy Temperature Measurement range: -35 °C to 80 °C (-31 °F to 17 Accuracy (overall error)': 0.45 °C (0.86 °F) typ (5 °C to 60 °C) Internal resolution: 0.5 "C (1 °F) typ Long term stability: <0.02 °C (0.86 °F) typ (5 °C to 60 °C) Alarm threshold range (software-selectable): -35 "C to 79.5 °C (-30 °F to 175 ’F) (high and low alarms) USB-502-PLUS Relative Humidity (%RH) Measurement range: 0% to 100% Accuracy (overall error)1: ±2.0 typ, ±4.0 max Specifies the overall error in the logged readings for relative...

Open the catalog to page 7
USB-500/600 series - 8

Data Sampling Max event or state change samples: 32,510 Timing accuracy: ±3 s per day at 20 °C Sampling intervals (software-selectable): 10 s, 30 s, 1 min, 5 min, 15 min, 30 min Max event samples: 32,510 Voltage Logger Voltage Measurement range: 0 VDC to 30 VDC Internal resolution: 50 mVDC Accuracy (overall error): ±1% typ USB device type: USB 2.0 (full speed) Device compatibility: USB 1.1, USB 2.0 Data Sampling Sampling intervals (software-selectable): 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Max voltage samples: 32,510 Units: VDC Power source: 1/2AA 3.6...

Open the catalog to page 8
USB-500/600 series - 9

Typical and maximum tolerance for USB-602 temperature sensor in °C. USB-601 Temperature Logger with Graphic LCD Screen Temperature Measurement range: -30 'C to 80 'C (-22 °F to176 °F) Internal resolution: 0.1 'C (0.1 'F) typ Accuracy (overall error)1: 0.35 °C (0.59 °F) typ (5 °C to 60 °C) Data Sampling Sampling intervals (software-selectable): 10 s, 15 s, 20 s, 30 s, 1 min, 2 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 2 h Max temperature samples: 252,928 Units: 'C or 'F USB Specifications USB device type: USB 2.0 (full speed) Device compatibility: USB 1.1, USB 2.0 Power Power source:...

Open the catalog to page 9