200W Slim Type with PFC Switching Power Supply series Video (only for UHP-200-24) Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 ■ ‧ ‧ ‧ ‧ ‧-~+℃ ‧ ‧ ‧ ‧ ‧ ■ ‧ ‧ ‧ ‧
Open the catalog to page 1200W Slim Type with PFC Switching Power Supply RATED CURRENT RATED POWER LINE REGULATION LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE FREQUENCY RANGE INRUSH CURRENT (Typ.)Note.8 Cold start 40A/115VAC LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE <0.75mA / 240VAC 110~140% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8~ 4.6V Protection type :Shut down O/P voltage,re-power on to recover Protection type :Shut down O/P voltage or Hiccup mode, recovers automatically after temperature goes down Contact rating(max.):15Vdc/10mA resistive...
Open the catalog to page 2200W Slim Type with PFC Switching Power Supply Block Diagram POWER SWITCHING DETECTION CIRCUIT DC OK Function Redundant Function Derating Curve RATED CURRENT (%) RATED CURRENT (%) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE(℃) RATED CURRENT (%)
Open the catalog to page 3200W Slim Type with PFC Switching Power Supply STATIC CHARACTERISTIC Function Manual 1.DC_OK Signal DC_OK is a collector shorted signal. It is used by an optocoupler in the power supply which indicates the output status of the power supply as exhibited below. Optocoupler Rating(max.) 2.Redundant function (1) UHP-200R is built-in redundant function and can be connected 2 units in parallel . (2) When in parallel operation the maximum load should not be greater than the rated power of any PSU.
Open the catalog to page 4200W Slim Type with PFC Switching Power Supply Mechanical Specification CASE NO.:249B Mating Housing
Open the catalog to page 5200W Slim Type with PFC Switching Power Supply Installation 1.Operate with additional aluminum plate In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-200 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-200 series must be firmly mounted at the center of the aluminum plate.
Open the catalog to page 62 Pages
7 Pages
74 Pages
5 Pages
9 Pages
14 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
104 Pages