50W Quad Output Switching Power Supply Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty SPECIFICATION MODEL OUTPUT NUMBER RATED CURRENT CURRENT RANGE RATED POWER OUTPUT LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT LINE REGULATION SETUP, RISE TIME 10ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 75% 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 6) EMC EMISSION Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
Open the catalog to page 150W Quad Output Switching Power Supply Mechanical Specification Assignment DC OUTPUT V3 DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER Block Diagram DETECTION CIRCUIT Derating Curve Output Derating VS Input Voltage Ta=25 100 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RQ-50-SPEC 2011-08-19
Open the catalog to page 22 Pages
7 Pages
6 Pages
74 Pages
5 Pages
9 Pages
14 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
104 Pages