50W Dual Output Switching Power Supply ¡EIsolated output & GND for CH1,CH2 ¡EUniversal AC input / Full range ¡EProtections: Short circuit / Overload / Over voltage ¡ECooling by free air convection ¡ELED indicator for power on ¡E100% full load burn-in test ¡EAll using 105¢J long life electrolytic capacitors ¡EWithstand 300VAC surge input for 5 second ¡EHigh operating temperature up to 70¢J ¡EWithstand 5G vibration test ¡EHigh efficiency, long life and high reliability ¡E3 years warranty .. SPECIFICATION MODEL OUTPUT NUMBER RATED CURRENT CURRENT RANGE RATED POWER OUTPUT RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 14ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 81% <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMC EMISSION (Note 6) EMC IMMUNITY MTBF OTHERS DIMENSION PACKING Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70¢J (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85¢J, 10 ~ 95% RH ¡Ó0.03%/¢J (0 ~ 50¢J)on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 172.6Khrs min. MIL-HDBK-217F (25¢J) 99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.9CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
Open the catalog to page 150W Dual Output Switching Power Supply Mechanical Specification Assignment DC OUTPUT +V2 DC OUTPUT G1 DC OUTPUT +V1 Block Diagram fosc : 50KHz RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT Output Derating VS Input Voltage Derating Curve
Open the catalog to page 22 Pages
7 Pages
6 Pages
74 Pages
5 Pages
9 Pages
14 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
104 Pages