35W Dual Output Switching Power Supply ¡EUniversal AC input / Full range ¡EProtections: Short circuit / Overload / Over voltage ¡ECooling by free air convection ¡ELED indicator for power on ¡E100% full load burn-in test ¡EAll using 105¢J long life electrolytic capacitors ¡EWithstand 300VAC surge input for 5 second ¡EHigh operating temperature up to 70¢J ¡EWithstand 5G vibration test ¡EHigh efficiency, long life and high reliability ¡E3 years warranty .. SPECIFICATION MODEL OUTPUT NUMBER RATED CURRENT CURRENT RANGE RATED POWER OUTPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE FREQUENCY RANGE 16ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 6) EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70¢J (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85¢J, 10 ~ 95% RH ¡Ó0.03%/¢J (0 ~ 50¢J)on CH1 output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950, TUV EN60950 approved I/P-O/P:3KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 179Khrs min. MIL-HDBK-217F (25¢J) 99*82*36mm (L*W*H) 0.3Kg; 45pcs/14Kg/0.83CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
Open the catalog to page 135W Dual Output Switching Power Supply Mechanical Specification Assignment DC OUTPUT V2 DC OUTPUT COM DC OUTPUT V1 Block Diagram RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT OUTPUT RIPPLE (mVp-p) Derating Curve
Open the catalog to page 22 Pages
7 Pages
6 Pages
74 Pages
5 Pages
9 Pages
14 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
104 Pages