QP-100 series
1 / 3Pages

Catalog excerpts

QP-100 series - 1

100W Quad Output with PFC Function Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage Free air cooling convection CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty OUTPUT NUMBER RATED CURRENT CURRENT RANGE RATED POWER (max.) OUTPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE AC CURRENT (Typ.) INRUSH CURRENT (Typ.) POWER FACTOR (Typ.) INPUT FREQUENCY RANGE 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING NOTE LEAKAGE CURRENT CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 139.9K hrs min. MIL-HDBK-217F (25 199*99*50mm (L*W*H) 0.87Kg; 20pcs/18.4Kg/1.28CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-100-SPEC 2011-08-19

Open the catalog to page 1
QP-100 series - 2

100W Quad Output with PFC Function Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Free air cooling convection CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty OUTPUT NUMBER RATED CURRENT CURRENT RANGE RATED POWER (max.) OUTPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP....

Open the catalog to page 2
QP-100 series - 3

100W Quad Output with PFC Function Mechanical Specification Terminal Pin No. Assignment : Pin No. Pin No. Assignment Assignment 1 5 AC/L DC OUTPUT V3 2 6,7 AC/N DC OUTPUT V1 3 FG 8,9 DC OUTPUT COM 4 DC OUTPUT V4 10 DC OUTPUT V2 Block Diagram POWER SWITCHING RECTIFIERS & FILTER RECTIFIERS & FILTER MA & CONTROL RECTIFIERS & FILTER Derating Curve Output Derating VS Input Voltage AMBIENT TEMPERATURE ( )

Open the catalog to page 3

All Mean Well catalogs and technical brochures

  1. RS-25 series

    2 Pages

  2. NHDD-40

    5 Pages

  3. TP-75 series

    3 Pages

  4. SP-75

    2 Pages

  5. PSP series

    3 Pages

  6. SE-200 serie

    2 Pages

  7. SE-100

    2 Pages

  8. NET series

    2 Pages

  9. NED series

    2 Pages

  10. NES series

    2 Pages

  11. RQ series

    2 Pages

  12. RID series

    2 Pages

  13. RD series

    2 Pages

  14. RS series

    2 Pages

  15. catalog

    104 Pages