600W with PFC and Parallel Function ¡EUniversal AC input / Full range ¡EBuilt-in active PFC function ¡EProtections: Short circuit / Overload / Over voltage / Over temperature ¡EForced air cooling by built-in DC fan ¡EWith DC OK Signal output ¡ECurrent sharing up to 2400W(3+1) ¡EBuilt-in remote ON-OFF control ¡EBuilt-in remote sense function ¡EFixed switching frequency at PFC:88KHz PWM:100KHz ¡E3 years warranty .. SPECIFICATION MODEL RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note.2 180mVp-p OUTPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD <1.3mA/240VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE 5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover +5V: 95¢J(TSW1) detect on heatsink of power transistor; 95¢J(TSW51) detect on heatsink of power diode OVER TEMPERATURE +12V ~ +48V: 85¢J(TSW1) detect on heatsink of power transistor; 80¢J(TSW51) detect on heatsink of power diode Protection type : Shut down o/p voltage, re-power on to recover REMOTE CONTROL POK SIGNAL WORKING TEMP. RC+/RC-: Short = power on ; Open = power off PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V -20 ~ +60¢J (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF OTHERS NOTE DIMENSION PACKING ¡Ó0.03%/¢J (0 ~ 50¢J) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 116.4K hrs min. MIL-HDBK-217F (25¢J) 170*120*93mm (L*W*H) 1.9Kg; 8pcs/15.5Kg/1.06CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:PSP-600-SPEC 2012-06-04
Open the catalog to page 1600Wwith PFCand Parallel Function Derating Curve 1 Output Derating VS Input Voltage AMBIENT TEMPERATURE ( )
Open the catalog to page 2600W with PFC and Parallel Function Control Terminal Instruction Manual POK(+) RCG(-) Remote Sensing Remote Control Power ON: RCG and RC for short Power OFF: RCG and RC for open POK Signal is the voltage difference between "RCG" and "POK" pin output POK Signal for TTL level signal PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V Parallel Operation with Remote Sensing (1)Parallel operation is available by connecting the units shown as below (+S,-S and P are connected mutually in parallel) : (2)The voltage difference among each output should be minimized that less than 0.2V is required. (3)The total...
Open the catalog to page 32 Pages
7 Pages
6 Pages
74 Pages
5 Pages
9 Pages
14 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
104 Pages