600W with PFC and Parallel Function series User’s Manual ■ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ■ https://www.meanwell.com/serviceGTIN.aspx Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 SPECIFICATION MODEL RATED CURRENT CURRENT RANGE RATED POWER LINE REGULATION LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE FREQUENCY RANGE AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER TEMPERATURE 5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover REMOTE CONTROL POK SIGNAL WORKING TEMP. RC+/RC-: Short = power on ; Open = power off PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V -20 ~ +60℃ (Refer to "Derating Curve") OVER VOLTAGE WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF OTHERS NOTE DIMENSION PACKING -40 ~ +85℃, 10 ~ 95% RH non-condensing ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, GB9245, GB17625.1, BSMI CNS15936, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 1132.9K hrs min. Telcordia SR-332 (Bellcore) ; 142.2K hrs min. 170*120*93mm (L*W*H) 1.9Kg; 8pcs/15.5Kg/1.00CUFT
Open the catalog to page 1600W with PFC and Parallel Function PSP-600 series Mechanical Specification (Unit: mm , tolerance ±0.5mm) Mating Housing Terminal Block Diagram JST SXH-001T or equivalent Derating Curve Output Derating VS Input Voltage AMBIENT TEMPERATURE (°C) INPUT VOLTAGE (V) 60Hz
Open the catalog to page 2600W with PFC and Parallel Function PSP-600 series ■ Control Terminal Instruction Manual RCG RC POK Signal Remote Sensing POK Signal is the voltage difference between "RCG" and "POK" pin output POK Signal for TTL level signal Remote Control Power ON: RCG and RC for short Power OFF: RCG and RC for open ■ Parallel Operation with Remote Sensing (1) Parallel operation is available by connecting the units shown as below (+S,-S and P are connected mutually in parallel) : (2) The voltage difference among each output should be minimized that less than 0.2V is required. (3) The total output current must...
Open the catalog to page 32 Pages
7 Pages
6 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
74 Pages
5 Pages
9 Pages
14 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
104 Pages