Model SADPminiEx Intrinsically Safe Hand-Held Dewpoint Hygrometer Certified Intrinsically Safe for use in explosive atmospheres: II 1G User Selectable Units - ºC, ºF, ppm(v), ppb(v), ppm(w), g/m3, lbs/MMSCF Desiccant Dry Down Assembly for Quick Measurements Advanced DATA Logging & PC Download Electronic Automatic Calibration Pressure Correction Computation Desiccant Dry Down Technology Real Time Graphic Logging to PC Various Ranges between -110ºC to + 20ºC sample gas inlet Sensor surrounded is by desiccant, ensuring that it is dry, when not in use. Dry-Down Position sample exhaust Unique design ensures purging of both void space and all chamber wall surfaces by sample gas prior to taking a reading dewpoint Read Position True Hand Held Portable Device Fully Self-Contained User Friendly Multi-Level Security to Prevent Unauthorised sensor exposed to gas sample The desiccant is always isolated from atmospheric air, and the sensor to ensure an accurate reading Desiccant Head assembly Keeping the sensor dry between tests ensures that the SADPmini is always ready to carry out rapid spot checks . The unique design of the Desiccant Head achieves this by surrounding the sensor with desiccant when taking a measurement. At no time is the sensor allowed to come into contact with ambient air. The chamber is also designed so that the void space and chamber wall surfaces are purged with sample gas, before exposure of the sensor , so giving faster, more accurate and reliable results. Alpha Moisture Systems Alpha House, 96 City Road Bradford, BD8 8ES England Robust Ergonomically Designed Custom Housing Tel QUALITY MANAGEMENT
Open the catalog to page 1MODEL SADPminiEx - Intrinsically Safe Hand-Held Dewpoint Hygrometer SENSING ELEMENT: Ultra Hi-Capacitance Aluminium Oxide Type As TYPE B plus following additional specifications & features: INTRINSIC SAFETY: Standard : EN 50014:1997+A1+A2 / EN 50020:2002 / EN 50284:1999 Code : RANGE IN DEW POINT: SR: -110ºC to -20ºC (-166ºF to -4ºF ) dew point PL: -100ºC to 0ºC (-148ºF to +32ºF ) dew point RD: -80ºC to -20ºC (-112ºF to -4ºF) dew point GY: -80ºC to 0ºC (-112ºF to +32ºF ) dew point BL: -80ºC to +20ºC (-112ºF to +68ºF ) dew point DISPLAY UNITS: ºC - Degrees Centigrade Dew / Frost Point ºF -...
Open the catalog to page 2MODEL SADPminiEx Intrinsically Safe Hand-Held Dewpoint Hygrometer Ordering Information S: Serial Port (Windows®95) U: USB (Windows®2000 or later) (Choose only for Type L. Leave blank for Type B or Type F) MAINS PLUG TYPE- For Battery Charger = XX TYPE = X B: Standard F: With 4-20mA Analogue Output L: With logging, RS485 Comms. & 4-20mA Output Standard UK, 3 Square pin 2 Vertical Flat Blade 2 Round Pins 2 Oblique FlatBlades with Ground diagram below) SAMPLE CONNECTION = X 4: 0.25” Swagelok® SS Compression Type 6: 0.6 mm Swagelok® SS Compression Type To order device with range -80°C to 0°C...
Open the catalog to page 3All Meagacon AS catalogs and technical brochures
-
MT-VA
2 Pages
-
MT-VF
2 Pages
-
MT-AW-R
3 Pages
-
MT-FP
2 Pages
-
MT-FW/R
3 Pages
-
MXG105 LOAD UNIT
1 Pages
-
MEVx Series
1 Pages
-
MCVBx Series
1 Pages
-
MEVx-0,2 Series
1 Pages
-
MCVBx-0,2 Series
1 Pages
-
MSA11B Series
1 Pages
-
MSA11E Series
1 Pages
-
MSA12B Series
1 Pages
-
KPM30x Series
2 Pages
-
KPM303x Series
2 Pages
-
KCT3x Series
1 Pages
-
FA Frequency Meter Series
5 Pages
-
Integra Series
4 Pages
-
PQ Voltmeter Series
6 Pages
-
SADPmini Series
4 Pages
-
Switches F1Pxx Series
2 Pages
-
D.C. DIN Shunts
2 Pages
-
KCM165K
3 Pages
-
KPM465x
3 Pages
-
KPM26x
4 Pages
-
KPM163FQ
2 Pages
-
KPM161FQ
2 Pages
-
K R M 1 6 1 - D C
1 Pages
-
KPM 16xM
3 Pages
-
K P M 1 6 x
5 Pages
-
DC SIGNAL ISOLATOR
1 Pages
-
Voltage Comparator
1 Pages
-
SECTOR SYNCHRONISING RELAY
2 Pages
-
GENERATOR CONTROLLER
2 Pages