Catalog excerpts
UNITA' DOSATRICE VOLUMETRICA:Layout 1.qxd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:10.00pt "Arial", sans-serif; } .font3 { font:16.00pt "Arial", sans-serif; } .font4 { font:25.00pt "Arial", sans-serif; } .font5 { font:8.60pt "Arial Black", sans-serif; } .font6 { font:11.00pt "Arial Black", sans-serif; } MPxWx/MPxRx POWER MEASURING TRANSDUCER (WATT & VAr) Active Power (Watt) or Reactive Power (kVAr) Transducer for balanced or unbalanced load Precision true RMS class 0,5 (kW) and class 1 (kVAr) measurement, notaffected byany waveformdistortion For use with 1A or 5A current transformers Very fast analogue output response time (<50mS) 1500V Galvanic isolation Spcifications Description System Voltage and 100-120,200-240, 380-415 or Auxiliary Supply: 440-460VAC, 40-70Hz To be used in applications that require a very fast response, precision monitoring of active/reactive power. Ideal for systems for regulation and control of the load on generators, motors and inverters. The MPxWxE is a high precision power transducer for balanced or unbalanced load system active (W) or reactive (VAr). The unit has ONE very fast response analogue output signal, with amplitude proportional to the measured active power (W) or reactive power (VAr) level. The noise-immune mAoutput is isolated from both the C.T. and voltage inputs and auxiliary power. Agreen "Supply On" LED indicates the auxiliary supply presence. Shown beloware designations for the available circuit configurations: ACTIVE POWER (W) MP1W2E -1 element, single phase, 2 wire MP1W3E -1 element, 3 phase, 3 wire, balanced load MP2W3E - 2 element, 3 phase, 3 wire, unbalanced load MP3W4E - 3 element, 3 phase, 4 wire, unbalanced load REACTIVE POWER (VAr) MP1R2E -1 element, single phase, 2 wire MP1R3E -1 element, 3 phase, 3 wire, balanced load MP2R3E - 2 element, 3 phase, 3 wire, unbalanced load MP3R4E - 3 element, 3 phase, 4 wire, unbalanced load The unit meets IEC60092-504 and the relevant environmental and EMC tests specified in IEC60068/60092 and IEC61000/60533 respectively, to comply with the requirements of the major Classification Societies. Optional Auxiliary Voltage:_ 18-36 or 36-160VDC Current Input: 1 or5AC.T. Analogue Output: -1/0/+10, -10/0/+10, -20/0/+20, 0-10, 0^20,4-20,4,3-20,4/5,45/20, 4/12/20mA,max500Ror 0-10, 0,2-10V,min10kohm_ Temperature: -20to+70°C Weight: 0.5kgs Front protection: IP54 (IP65 optional) mCQQCOn Norway - UK
Open the catalog to page 1All Meagacon AS catalogs and technical brochures
-
MT-VA
2 Pages
-
MT-VF
2 Pages
-
MT-AW-R
3 Pages
-
MT-FP
2 Pages
-
MT-FW/R
3 Pages
-
MXG105 LOAD UNIT
1 Pages
-
MEVx Series
1 Pages
-
MCVBx Series
1 Pages
-
MEVx-0,2 Series
1 Pages
-
MCVBx-0,2 Series
1 Pages
-
MSA11B Series
1 Pages
-
MSA11E Series
1 Pages
-
MSA12B Series
1 Pages
-
KPM30x Series
2 Pages
-
KPM303x Series
2 Pages
-
KCT3x Series
1 Pages
-
FA Frequency Meter Series
5 Pages
-
Integra Series
4 Pages
-
PQ Voltmeter Series
6 Pages
-
SADPminiEx Series
3 Pages
-
SADPmini Series
4 Pages
-
Switches F1Pxx Series
2 Pages
-
D.C. DIN Shunts
2 Pages
-
KCM165K
3 Pages
-
KPM465x
3 Pages
-
KPM26x
4 Pages
-
KPM163FQ
2 Pages
-
KPM161FQ
2 Pages
-
K R M 1 6 1 - D C
1 Pages
-
KPM 16xM
3 Pages
-
K P M 1 6 x
5 Pages
-
DC SIGNAL ISOLATOR
1 Pages
-
Voltage Comparator
1 Pages
-
SECTOR SYNCHRONISING RELAY
2 Pages
-
GENERATOR CONTROLLER
2 Pages