MT-VF
2Pages

{{requestButtons}}

Catalog excerpts

MT-VF - 1

MEASURING TRANSDUCER - AC VOLTAGE AND FREQUENCY MT-VF • Combined AC Voltage (V) and Frequency (Hz) Transducer • Precision true RMS class 0,5 measurement, not affected by any waveform distortion • For Voltage measurement up to 500VAC • For Frequency measurement 30-70Hz • Up to two individual very fast analogue output signals (<50mS), (optional) • DIN96 Slave Indicators with full scale (optional) Specifications Monitored Voltage: The digitally controlled PMT-VF is a precision transducer for AC Voltage (A) and Frequency (Hz). Standard Auxiliary Voltage AC: Optional Separate Auxiliary Voltage DC: Supply tolerance: Power rating: Frequency range: (Other range on request) Analogue output 1: (Volt range) To be used in applications that require a very fast response, precision monitoring of voltage and frequency. The unit measures the voltage and current true r.m.s. value, and accuracy is independent of any wave form distortion. Agreen LED (ON) indicates the auxiliary supply presence. LED status Power Two individual very fast analogue output signals proportional to AC Voltage (V) and Frequency (Hz) level. If an output is used for remote meter reading, we recommend 0-1mAfor the slave indicator. It also includes an additional RJ12 output for a DIN96 Slave Indicator (optional). Analogue output 2: (Hz range) The noise-immune mA output is isolated from voltage inputs and auxiliary power. The unit take the auxiliary supply voltage from terminal 26 & 27. (see page 2 for available outputs) Accuracy: Temperature: Humidity, relative: Weight: Front protection: Flammability: It can also be delivered with optional separate DC auxiliary voltage (terminal 26 & 27), but that must be specified when ordering (see page 2 for ordering code for separate DCAux. Supply). The unit meets EN 60255-27 Cat. III, Pollution degree 2 and the relevant environmental and EMC tests specified in EN 60255-26 to comply with the requirements of the major Classification Societies. Norway Denmark United Kingdom www.megacon.com ELECTRONIC CONTROL AND INSTRUMENTATION Page: 1 of 2 REF: Datasheet.MT-VF - REV: 1.00/04.2021 © All rights reserved to Megacon Megacon reserves the right to make any changes to the information

Open the catalog to page 1
MT-VF - 2

MEASURING TRANSDUCER - AC VOLTAGE AND FREQUENCY MT-VF Connection Diagram Analogue Output Connection Diagram without optional slave instrument The output signals are proportional to the meter reading. L1 L2 The signal is specifically intended as an input to a control system for monitoring or control. L3 Add suffix from table below to type designation to specify output required: Monitored Voltage *Note: AC AUX. Supply (Standard) Separate DC Aux. Supply (Optional) Connection Diagram with optional slave instrument L1 Connection Terminal type Wire max. Monitored Voltage : Terminal Clamp and...

Open the catalog to page 2

All Meagacon AS catalogs and technical brochures

  1. MT-VA

    2 Pages

  2. MT-AW-R

    3 Pages

  3. MT-FP

    2 Pages

  4. MT-FW/R

    3 Pages

  5. MEVx Series

    1 Pages

  6. MCVBx Series

    1 Pages

  7. KCT3x Series

    1 Pages

  8. KCM165K

    3 Pages

  9. KPM465x

    3 Pages

  10. KPM26x

    4 Pages

  11. KPM163FQ

    2 Pages

  12. KPM161FQ

    2 Pages

  13. KPM 16xM

    3 Pages

  14. K P M 1 6 x

    5 Pages