MEASURING TRANSDUCER - FREQUENCY, ACTIVE OR REACTIVE POWER MT-FW/R • Combined Frequency (Hz), Active Power (Watt) or Reactive Power (VAr) Transducer for balanced or unbalanced load • Precision true RMS class 0,5 (Hz & Watt) and class 1 (VAr) measurement, not affected by any waveform distortion • For use with 1A or 5A current transformers • Up to two individual very fast analogue output signals (<50mS), (optional) • DIN96 Slave Indicators with full scale (optional) Specifications Monitored Voltage: The digitally controlled MT-FW/R is a precision transducer for frequency (Hz) and balanced or unbalanced load system active (Watt) or reactive (VAr). To be used in applications that require a very fast response, precision monitoring of frequency, active or reactive power. Ideal for systems for regulation and control of the load on generators, motors and inverters. The unit measures the voltage and current true r.m.s. value, and accuracy is independent of any wave form distortion. Agreen LED (ON) indicates the auxiliary supply presence. Optional Separate Auxiliary Voltage DC: Supply tolerance: Power rating: Current Input: Frequency range: (Other range on request) Analogue output 1: (Any % of the Hz range) Two individual very fast analogue output signals proportional to Frequency (Hz), the measured Active Power (Watt) or Reactive Power (VAr) level. (See page 3 for an overview of models). If an output is used for remote meter reading, we recommend 0-1mAfor the slave indicator. It also includes an additional RJ12 output for a DIN96 Slave Indicator (optional). The noise-immune mA output is isolated from both the C.T. and voltage inputs and auxiliary power. Analogue output 2: (Watt or VAr range) (see page 3 for available outputs) mA: Up to 20mA, max 500R V: Up to 10V, min 5kohm or optional 500ohm (other on request) Accuracy: Temperature: Humidity, relative: Weight: Front protection: Flammability: The standard models takes the auxiliary supply voltage from the monitored voltage (terminal 1 & 2). It can also be delivered with optional separateAC or DC auxiliary voltage (terminal 26 & 27), but that must be specified when ordering (see page 3 for ordering code for separateAux. Supply). The unit meets EN 60255-27 Cat. III, Pollution degree 2 and the relevant environmental and EMC tests specified in EN 60255-26 to comply with the requirements of the major Classification Societies. Norway Denmark United Kingdom www.megacon.com ELECTRONIC CONTROL AND INSTRUMENTATION Page: 1 of 3 REF: Datasheet.MT-FW/R - REV: 1.00/04.2021 © All rights reserved to Megacon Megacon reserves the right to make any changes to the information at
Open the catalog to page 1MEASURING TRANSDUCER - FREQUENCY, ACTIVE OR REACTIVE POWER MT-FW/R Connection Diagram Connection Diagram Separate AC or DC Aux.Supply (Optional) Monitored Voltage (*Note) Separate AC or DC Aux.Supply (Optional) Monitored Voltage (*Note) Optional earth connection Optional earth connection Com. cable to slave indicator + - + Analogue Analogue output 1 output 2 (Hz) (Watt or VAr) Com. cable to slave indicator Com. cable to slave indicator + Analogue output 2 (Watt or VAr) Com. cable to slave indicator Optional DIN96 slave indicators Optional DIN96 slave indicators MFI96E Connection Diagram...
Open the catalog to page 2MEASURING TRANSDUCER - FREQUENCY, ACTIVE OR REACTIVE POWER MT-FW/R Model Overview Analogue Output Frequency (Hz) and Active Power (W) 1 element, single phase 1 element, 3 phase, 3 wire, balanced load 1 element, 3 phase, 4 wire, balanced load 2 element, 3 phase, 3 wire, unbalanced load 3 element, 3 phase, 3 wire, unbalanced load 3 element, 3 phase, 4 wire, unbalanced load The output signals are proportional to the meter reading. The signal is specifically intended as an input to a control system for monitoring or control. Add suffix from table below to type designation to specify output...
Open the catalog to page 3All Meagacon AS catalogs and technical brochures
-
MT-VA
2 Pages
-
MT-VF
2 Pages
-
MT-AW-R
3 Pages
-
MT-FP
2 Pages
-
MXG105 LOAD UNIT
1 Pages
-
MEVx Series
1 Pages
-
MCVBx Series
1 Pages
-
MEVx-0,2 Series
1 Pages
-
MCVBx-0,2 Series
1 Pages
-
MSA11B Series
1 Pages
-
MSA11E Series
1 Pages
-
MSA12B Series
1 Pages
-
KPM30x Series
2 Pages
-
KPM303x Series
2 Pages
-
KCT3x Series
1 Pages
-
FA Frequency Meter Series
5 Pages
-
Integra Series
4 Pages
-
PQ Voltmeter Series
6 Pages
-
SADPminiEx Series
3 Pages
-
SADPmini Series
4 Pages
-
Switches F1Pxx Series
2 Pages
-
D.C. DIN Shunts
2 Pages
-
KCM165K
3 Pages
-
KPM465x
3 Pages
-
KPM26x
4 Pages
-
KPM163FQ
2 Pages
-
KPM161FQ
2 Pages
-
K R M 1 6 1 - D C
1 Pages
-
KPM 16xM
3 Pages
-
K P M 1 6 x
5 Pages
-
DC SIGNAL ISOLATOR
1 Pages
-
Voltage Comparator
1 Pages
-
SECTOR SYNCHRONISING RELAY
2 Pages
-
GENERATOR CONTROLLER
2 Pages