Catalog excerpts
MEASURING TRANSDUCER - POWER FACTOR AND FREQUENCY MT-FP • Combined Frequency (Hz) and Power Factor (Cosφ) Transducer • Precision true RMS class 0,5 measurement, not affected by any waveform distortion • For use with 1A or 5A current transformers • For Frequency measurement 30-70Hz • Up to two individual very fast analogue output signals (<50mS), (optional) • DIN96 Slave Indicators with full scale (optional) Specifications Monitored Voltage: 0-500VAC 30-70Hz (Fuse 0,5A) Standard Auxiliary Voltage AC: Optional Separate Auxiliary Voltage DC: Supply tolerance: Power rating: Current Input: Frequency range: The digitally controlled MT-FP is a precision transducer for Frequency (Hz) and Power Factor (Cosφ). To be used in applications that require a very fast response, precision monitoring of power factor and frequency. The unit measures the voltage and current true r.m.s. value, and accuracy is independent of any wave form distortion. Agreen LED (ON) indicates the auxiliary supply presence. (Other range on request) Analogue output 1: (Any % of the Hz range) Two individual very fast analogue output signals proportional to Frequency (Hz) and Power Factor (Cosφ) level. If an output is used for remote meter reading, we recommend 0-1mAfor the slave indicator. It also includes an additional RJ12 output for a DIN96 Slave Indicator (optional). Analogue output 2: (Cos Phi range 0,5 CAP/1/0,5 IND) mA: Up to 20mA, max 500R V: Up to 10V, min 5kohm or optional 500ohm (other on request) The noise-immune mA output is isolated from voltage inputs and auxiliary power. The unit take the auxiliary supply voltage from terminal 26 & 27. (see page 2 for available outputs) Accuracy: Temperature: Humidity, relative: Weight: Front protection: Flammability: It can also be delivered with optional separate DC auxiliary voltage (terminal 26 & 27), but that must be specified when ordering (see page 2 for ordering code for separate DCAux. Supply). The unit meets EN 60255-27 Cat. III, Pollution degree 2 and the relevant environmental and EMC tests specified in EN 60255-26 to comply with the requirements of the major Classification Societies. Norway Denmark United Kingdom www.megacon.com ELECTRONIC CONTROL AND INSTRUMENTATION Page: 1 of 2 REF: Datasheet.MT-FP - REV: 1.00/04.2021 © All rights reserved to Megacon Megacon reserves the right to make any changes to the informati
Open the catalog to page 1MEASURING TRANSDUCER - POWER FACTOR AND FREQUENCY MT-FP Connection Diagram Analogue Output Connection Diagram without optional slave instrument The output signals are proportional to the meter reading. L1 L2 The signal is specifically intended as an input to a control system for monitoring or control. L3 Add suffix from table below to type designation to specify output required: Monitored Voltage Optional earth connection *Note: AC AUX. Supply (Standard) Separate DC Aux. Supply (Optional) + Analogue output 2 (Cosφ) Connection Diagram with optional slave instrument L1 Connection Terminal...
Open the catalog to page 2All Meagacon AS catalogs and technical brochures
-
MT-VA
2 Pages
-
MT-VF
2 Pages
-
MT-AW-R
3 Pages
-
MT-FW/R
3 Pages
-
MXG105 LOAD UNIT
1 Pages
-
MEVx Series
1 Pages
-
MCVBx Series
1 Pages
-
MEVx-0,2 Series
1 Pages
-
MCVBx-0,2 Series
1 Pages
-
MSA11B Series
1 Pages
-
MSA11E Series
1 Pages
-
MSA12B Series
1 Pages
-
KPM30x Series
2 Pages
-
KPM303x Series
2 Pages
-
KCT3x Series
1 Pages
-
FA Frequency Meter Series
5 Pages
-
Integra Series
4 Pages
-
PQ Voltmeter Series
6 Pages
-
SADPminiEx Series
3 Pages
-
SADPmini Series
4 Pages
-
Switches F1Pxx Series
2 Pages
-
D.C. DIN Shunts
2 Pages
-
KCM165K
3 Pages
-
KPM465x
3 Pages
-
KPM26x
4 Pages
-
KPM163FQ
2 Pages
-
KPM161FQ
2 Pages
-
K R M 1 6 1 - D C
1 Pages
-
KPM 16xM
3 Pages
-
K P M 1 6 x
5 Pages
-
DC SIGNAL ISOLATOR
1 Pages
-
Voltage Comparator
1 Pages
-
SECTOR SYNCHRONISING RELAY
2 Pages
-
GENERATOR CONTROLLER
2 Pages