LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM
8Pages

{{requestButtons}}

Catalog excerpts

LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM - 1

Microsoft Word - 9000_607_39GB.doc table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:12.00pt "Arial", sans-serif; } .font5 { font:15.00pt "Arial", sans-serif; } .font6 { font:26.00pt "Arial", sans-serif; } .font7 { font:8.25pt "Arial Black", sans-serif; } .font8 { font:11.00pt "Tahoma", sans-serif; } KCG591x LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM All-in-one unit, the COMPLETE solution G59/2 Loss of Mains Protection Adjustable Supervision Delay Cause of Trip LEDs and Event Log Digitally Controlled Operation Tamper Proof configuration via the HHP1/HHP2 or via PC(HHP2only) Spcifications Self powered from monitored voltage input 24,110VDC_ Description The fully self-contained KCG591E provides prcision protection against malfunction and human and operational hazards under loss of mains conditions. The DIN rail mounted digitally controlled unit meets the protection requirements for generators connected to mains supply, such as defined in the G59/2 and similar recommendations. Less wiring, no extra modules. Operating mode is selected by simple auxiliary contacts on the generator breaker and on the mains breaker. LEDs and open collector outputs indicate operating mode and "First Up" cause oftrip. State-of-the-art digital technology throughout, with quartz-controlled Loss of Mains detection. True RMS measurements. Loss of Mains Protection KCG591E will provide the following protection: - 2 stage Overand UnderVoltage - 2 stage Overand Under Frequency - Rate of Change of Frequency ( ROCOF, df/dt) - Vector Shift (step phase angle) Auxiliary Voltage: Optional Auxiliary Voltage:_ Monitored Voltage input:_ 100-120, 200-240, 380-415 or 440-460VAC,4Cl70Hz Frequency Range: 45-65Hz RelayStandard: Latching relays as standard. User selectable to 3-180sec auto resetofalarms Contact Rating: AC: DC: 100VA-250V/2Amax. 50W-100V/1Amax. Open Collector Outputs:_ 30V DC max.- 500mA max. Settings: See page 4and5 Internal Watchdog: An independent watchdog monitors signal flow. Flashing ofLEDs1, 2 and3 in a binary pattern indicate operational Dielectric test/ Galvanic separation: error 4.0kVAC Climate: Class HUE, (DIN40040) Temperature: -20to+70°C Weight: 0.5kgs Front protection: IP41 Enclosure: Flame retardant polycarbonate to UL94 (VO) _ The unit meets IEC60093-504 and the relevant environmental and EMC tests specified in IEC60068/60092 and IEC61000/60533 respectively. Page 1 of 8 mCQQCOn Norway - UK

Open the catalog to page 1
LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM - 2

Microsoft Word - 9000_607_39GB.doc table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:8.00pt "Arial", sans-serif; } .font5 { font:9.00pt "Arial", sans-serif; } .font6 { font:10.40pt "Arial", sans-serif; } .font7 { font:25.00pt "Arial", sans-serif; } .font8 { font:26.00pt "Arial", sans-serif; } .font9 { font:8.25pt "Arial Black", sans-serif; } .font10 { font:11.00pt "Tahoma", sans-serif; }...

Open the catalog to page 2
LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM - 3

Microsoft Word - 9000_607_39GB.doc table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:8.00pt "Arial", sans-serif; } .font5 { font:9.00pt "Arial", sans-serif; } .font6 { font:13.00pt "Arial", sans-serif; } .font7 { font:17.00pt "Arial", sans-serif; } .font8 { font:21.60pt "Arial", sans-serif; } .font9 { font:23.00pt "Arial", sans-serif; } .font10 { font:25.00pt "Arial", sans-serif; } .font11...

Open the catalog to page 3
LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM - 4

Microsoft Word - 9000_607_39GB.doc table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:8.00pt "Arial", sans-serif; } .font5 { font:9.00pt "Arial", sans-serif; } .font6 { font:25.00pt "Arial", sans-serif; } .font7 { font:26.00pt "Arial", sans-serif; } .font8 { font:32.00pt "Arial", sans-serif; } .font9 { font:8.25pt "Arial Black", sans-serif; } .font10 { font:11.00pt "Tahoma", sans-serif; }...

Open the catalog to page 4
LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM - 5

Microsoft Word - 9000_607_39GB.doc table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:12.00pt "Arial", sans-serif; } .font3 { font:26.00pt "Arial", sans-serif; } .font4 { font:8.25pt "Arial Black", sans-serif; } .font5 { font:11.00pt "Tahoma", sans-serif; } KCG591x LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM Opration Setting the user adjustable parameters The final settings for KCG591E should ideally be subject to agreement between the electricity supply...

Open the catalog to page 5
LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM - 6

Datasheet_KSQ332EJD1 (rev 1.0... - pdfMachine from Broadgun Software, http://pdfmachine.com, a great PDF writer utility! table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:10.00pt "Arial", sans-serif; } .font3 { font:25.00pt "Arial", sans-serif; } .font4 { font:8.60pt "Arial Black", sans-serif; } KCG591x LOSS OF MAINS PROTECTION RELAY - SINGLE PHASE 2-WIRE SYSTEM Loss of Mains Protection The Loss of Mains protection is provided with two separate protection circuits and these...

Open the catalog to page 6

All Meagacon AS catalogs and technical brochures

  1. MT-VA

    2 Pages

  2. MT-VF

    2 Pages

  3. MT-AW-R

    3 Pages

  4. MT-FP

    2 Pages

  5. MT-FW/R

    3 Pages

  6. MEVx Series

    1 Pages

  7. MCVBx Series

    1 Pages

  8. KCT3x Series

    1 Pages

  9. KCM165K

    3 Pages

  10. KPM465x

    3 Pages

  11. KPM26x

    4 Pages

  12. KPM163FQ

    2 Pages

  13. KPM161FQ

    2 Pages

  14. KPM 16xM

    3 Pages

  15. K P M 1 6 x

    5 Pages