KPM26x
4Pages

{{requestButtons}}

Catalog excerpts

KPM26x - 1

AC INSULATION GUARD WITH MEASURING LOOP SUPERVISION KPM26x • Direct connection up to 500V line voltage, up to 6,6kV with HV adapter • Continuous supervision of measuring loop continuity • 2-level insulation relays and loop continuity relay • Immune to earth capacitance and voltage surges • For use in land, marine, offshore, sub-sea and ocean floor Installations • Analogue output proportional to meter reading (F-version) Specifications General Auxiliary Supply: Optional Voltage: Contact rating: Analogue Output: F-versions The prime purpose of the digitally controlled KPM26x is basically identical to the “traditional” KPM16x Insulation Guard range. An auxiliary Measuring Input Loop Continuity Monitoring Facility has been added to notify the operator if a measuring loop disruption may cause the meter to read a too high insulation level. The unit has C/O relay outputs for Warning, Alarm and loop failure. The Alarm relay is fail to safety configured. A trip LED flashes when the trip level is passed, the relay trips when the delay has elapsed. The timer resets if the fault is removed during countdown. Trip levels and delays are settable on unit rear. Temperature: Weight: Front protection: Only ONE KPM26x can be connected to each IT-system. The ohmmeter and the triple-zone status LEDs give at a glance the clear safety message: - ALARM (red zone) - WARNING (yellow zone) - HEALTHY (green zone) INTELLIGENT SETTING ASSISTANCE KPM263x has a built-in Assistance tool for setting/verification of the trip levels and the analogue output. General When either the Warning or Alarm potmeter on the rear is operated by user, the meter goes into Assistance Mode and meter reading and analogue output will reflect the potmeter setting. How to set alarm levels: Firstly adjust potmeter fully clockwise (see that meter goes to the top), then adjust potmeter down to required Warning or Alarm setpoint. Without any movement of potmeters, the meter will revert to normal Insulation Monitoring Mode after approximately 10 seconds. How to test analogue output signal: Adjust any trip level potmeter to activate Assistance Mode. Example: On a 4-20mA output, adjust potmeter fully anti clockwise for 4mAand fully clockwise for 20mA. The KPM263x range is designed to comply with specification AODC035 “Code of Practice for the Safe Use of Electricity Under Water” issued by IMCA. The unit meets IEC60092-504 and the relevant environmental and EMC tests specified in IEC60068/60092 and IEC61000/60533 respectively, to comply with the requirements of the major Classification Societies. IDV MEASURING PRINCIPLE Insulation is measured between the complete galvanically interconnected AC network and its protective earth. The signal flows to ground via the path of the insulation fault, the level of flow indicates the insulation resistance. The measuring accuracy is not influenced by any normal kind of load attached to theAC network, the processing time for KPM26x is approximately 400mS. MEASURING LOOPALARM A sensing resistor is mounted at the furthest end of the monitored loop in a separate Loop Resistance Sensor Module (LRSM-1,4 or LRSM-5). There are no restrictions on distance from the sensing resistor to the KPM26x unit. There is a fixed delay of 60 seconds on the loop failure alarm. The Loop alarm will notify the operator by activating LED LOOP FAILURE and trip relay 3. A disruption in the input measuring loop may cause the guard to falsely read a too high insulation level. The Measuring Input Loop Continuity Monitoring Facility is of special importance during lasting standby conditions (motors, lanterns etc). MEGGER SAFE When auxiliary power is OFF the unit input is automatically protected against “megger” test voltages up to 1.4kVDC, and incorrect measurements caused by the unit’s input impedance is avoided. OUTPUTS All F versions have an isolated analogue output proportional to meter reading. If output is used for remote meter reading, we recommend 0-1mAfor the slave indicator. SAFETY When a voltage adapter (CHx) is used the signal to terminals 4 and 6 on KPM261x and KPM263x is limited to a safe level, avoiding any dangerous voltage exposure to personnel. Norway Denmark United Kingdom www.megacon.com ELECTRONIC CONTROL AND INSTRUMENTATION Page: 1 of 4 REF: Datasheet.KPM26x - REV: 1.13/11.2015 © All rights reserved to Megacon Megacon reserves the right to make any changes to th

Open the catalog to page 1
KPM26x - 2

AC INSULATION GUARD WITH MEASURING LOOP SUPERVISION Loop Failure This unit is used for hospital, industrial, marine and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default 5 secs delay). Fail Safe Direct connection up to 500V line voltage. Model Latch KPM261E KPM261F KPM261G* X KPM261GF* X Adjustments Trip level WARNING: 0-1MΩ ALARM: 0-1MΩ Coloured sectors show recommended areas of settings: - Indicates alarm trip zone - Indicates warning trip zone - Indicates healthy zone Output table (example for 4-20mA) Range Relay Operation Loop...

Open the catalog to page 2
KPM26x - 3

AC INSULATION GUARD WITH MEASURING LOOP SUPERVISION Loop Failure This unit is used for marine, ROV and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default 10 secs delay). Fail Safe Direct connection up to 500V line voltage. Up to 6,6kV via HV adaptor CH163x orAN6,6 series. Model Latch KPM263E2 KPM263F2 KPM263G2* X KPM263GF2* X Adjustments Trip level WARNING: 0-10MΩ ALARM: 0-10MΩ Coloured sectors show recommended areas of settings: - Indicates alarm trip zone - Indicates warning trip zone - Indicates healthy zone Output table (example...

Open the catalog to page 3
KPM26x - 4

AC INSULATION GUARD WITH MEASURING LOOP SUPERVISION ~ Relays shown de-energised, a fail-safe relay energises when unit is powered. Reset (only latching versions) KPM261F, KPM261GF, KPM263F, KPM263GF, KPM263F2 and KPM263GF2 have an isolated analogue output proportional to meter reading. (Special outputs are available on request) 4 NOTE: See below for correct connection * To be connected to any line voltage or neutral * To be connected to any line voltage or neutral for up to 5kVAC NB! Only neutral connection for 6,6kVAC Note: LRSM-1,4 or LRSM-5 unit must be used together with all KPM26x...

Open the catalog to page 4

All Meagacon AS catalogs and technical brochures

  1. MT-VA

    2 Pages

  2. MT-VF

    2 Pages

  3. MT-AW-R

    3 Pages

  4. MT-FP

    2 Pages

  5. MT-FW/R

    3 Pages

  6. MEVx Series

    1 Pages

  7. MCVBx Series

    1 Pages

  8. KCT3x Series

    1 Pages

  9. KCM165K

    3 Pages

  10. KPM465x

    3 Pages

  11. KPM163FQ

    2 Pages

  12. KPM161FQ

    2 Pages

  13. KPM 16xM

    3 Pages

  14. K P M 1 6 x

    5 Pages