KCT3x Series

KCT3x Series

Product catalog summary
Overview: The document describes the KCT3, a three-channel temperature protection relay designed for use with PT100 inputs. It highlights the features, configurations, and specifications of the device.
Features: The KCT3 relay converts three PT100 inputs into three independent analogue signals. It supports both two-wire and three-wire PT100 inputs. The device is designed to process these signals based on the instrument type.
Typical Configurations:
  • KCT31: All three inputs connect to a common bus, with output relays operating on the highest input. It provides a single milliamp output relative to the highest input.
  • KCT32: Groups two inputs to one channel and the third input to a second channel, offering one relay output and one analogue output per grouping.
  • KCT33: Each input has an individual channel with one relay output and one analogue output.
Specifications:
  • Auxiliary Voltage: Options include 85-265V AC, 18-36V DC, 36-72V DC, and 100-300V DC.
  • Adjustments: Trip levels can be set from 0-100% FSD for levels 1 and 2, and 1-100% FSD for level 3.
  • Contact Rating: AC: 2A (415V, 800VA); DC: 250mA (50W resistive).
Ordering Information: When ordering, specify the auxiliary voltage, temperature range, and instrument type.
Note: The MEGACON policy emphasizes continuous improvement, which may result in variations in equipment details from the publication.
See more

Catalog excerpts

KCT3x Series-1

Three Channel Temperature Relay Three channel Temperature Protection Relay for use with PT100 inputs FEATURES The KCT3 converts three PT100 inputs to three independent analogue signals. These signals are processed depending upon the instrument type – see below. TEMPERATURE CONTROLLER The PT100 inputs can be of the two or three wire type. The three inputs are connected to a common bus with the three output relays operating on the highest input. A single milliamp output relative to the highest input. The three inputs are grouped with two inputs to one channel and the third input to a second channel. One relay output and one analogue output relative to each grouping. The three inputs each have an individual channel with one relay output and one analogue output. Auxiliary Voltage 85-265V AC 18-36V DC 36-72V DC 100-300V DC Adjustments Trip level 1 Trip level 2 Trip level 3 Contact Rating AC : 2A (415V, 800VA) DC : 250mA (50W resistive) Relays shown de-energised. ORDERING INFORMATION Auxiliary voltage : Temperature range : Instrument type : The MEGACON policy is one of continuous improvement, consequently equipment supplied may vary in detail from this publication Megacon International – Norway – UK - Denmark REF: MPD-1204 www.megacon.com The MEGACON policy is one of continuous improvement, consequently equipment supplied may vary in detail from this publicat

 Open the catalog to page 1

All Meagacon AS catalogs and technical brochures

  1. MT-VA

    2  Pages

  2. MT-VF

    2  Pages

  3. MT-AW-R

    3  Pages

  4. MT-FP

    2  Pages

  5. MT-FW/R

    3  Pages

  6. MEVx Series

    1  Page

  7. MCVBx Series

    1  Page

  8. KPM30x Series

    2  Pages

  9. KCM165K

    3  Pages

  10. KPM465x

    3  Pages

  11. KPM26x

    4  Pages

  12. KPM163FQ

    2  Pages

  13. KPM161FQ

    2  Pages

  14. KPM 16xM

    3  Pages

  15. K P M 1 6 x

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.