STANDBY INSULATION GUARD (MEGGER) FOR NON-GROUNDED SYSTEMS KCM165K • Direct connection up to 690V line voltage, up to 25kV with HV adapter, continuos standby monitoring for motors, pumps etc. • For use in land, marine, offshore Installations • ”Megger” - safe to 1.4kVDC when aux power is OFF • Parallelling Disable Function • Triple-zone insulation monitoring • Immune to earth capacitance • Analogue output proportional to meter reading • Optional slave indicator Application Specifications General Auxiliary Supply: Optional Voltage: Contact rating: The digitally controlled KCM165K monitors insulation level between a non-live non-grounded (IT) AC system and its protective earth. This unit is used for marine, offshore, seabed and down hole installations for megging in standby position. An AC or DC auxiliary voltage is required for the unit. Only ONE KCM16K can be connected to each ITsystem. The ohmmeter and the triple-zone status LEDs give at a glance the clear safety message: Analogue Output: (other on request) Temperature: Weight: Front protection: INTELLIGENT SETTING ASSISTANCE KCM165K has a built-in Assistance tool for setting/verification of the trip levels and the analogue output. When either the Warning or Alarm potmeter on the front is operated by user, the slave meter goes into Assistance Mode and meter reading and analogue output will reflect the potmeter setting. How to set alarm levels: Firstly adjust potmeter fully clockwise (see that slave meter goes to the top), then adjust potmeter down to required Warning or Alarm setpoint. Without any movement of potmeters, the meter will revert to normal Insulation Monitoring Mode after approximately 10 seconds. How to test analogue output signal: Adjust any trip level potmeter to activate Assistance Mode. Example: On a 4-20mA output, adjust potmeter fully anti clockwise for 4mAand fully clockwise for 20mA. The KCM165K range is designed to comply with specification AODC035 “Code of Practice for the Safe Use of Electricity Under Water” issued by IMCA. The unit meets IEC60092-504 and the relevant environmental and EMC tests specified in IEC60068/60092 and IEC61000/60533 respectively, to comply with the requirements of the major Classification Societies. - ALARM (red zone) - WARNING (yellow zone) - HEALTHY (green zone) General IDV MEASURING PRINCIPLE Insulation is measured between the complete galvanically interconnected AC network and its protective earth. The unit injects a 15VDC measuring signal into the monitored system. The signal flows to ground via the path of the insulation fault, the level of flow indicates the insulation resistance. The measuring accuracy is not influenced by any normal kind of load attached to the AC network. The KPM165K measures all phases just by connection to either line or neutral point. Start of monitoring function is delayed when auxiliary power is switched on (default 30 secs delay) to avoid false reading caused by initial charging of network spread capacitance. If powered from separate source there can be a stabilizing time if there is network spread capacitance. MEGGER SAFE When auxiliary power is OFF the unit input is automatically protected against “megger” test voltages up to 1.4kVDC, and incorrect measurements caused by the unit’s input impedance are avoided. OUTPUTS The unit has C/O relay outputs for Warning and Alarm. The Alarm relays are fail to safety configured. A trip LED flashes when the trip level is passed, the relay trips when the delay has elapsed. The timer resets if the fault is removed during countdown. Trip levels and delays are settable on unit front. The unit is supplied with an isolated analogue output proportional to insulation level. If output is used for remote meter reading, we recommend 0-1mAfor the slave indicator. SAFETY To protect the KCM165K and personnel against high voltage exposure a voltage adapter is needed for line-voltage above 690V. Norway Denmark United Kingdom www.megacon.com ELECTRONIC CONTROL AND INSTRUMENTATION Page: 1 of 3 REF: Datasheet.KCM165K - REV: 1.06/11.2015 © All rights reserved to Megacon Megacon reserves the right to make any changes t

Open the catalog to page 1
KCM165K - 2

STANDBY INSULATION GUARD (MEGGER) FOR NON-GROUNDED SYSTEMS Relay Operation Scale range: 500kΩ-5GΩ - The analogue output proportional to meter reading. Output diagram/table shows the values for a 4-20mAsignal. (Special outputs are available on request) Warning  Fail Safe Add suffix from table below to type designation to specify output required: O/P1 O/P2 O/P3 O/P4 O/P5   Adjustments Trip level WARNING: 500kΩ-3GΩ ALARM: 500kΩ-3GΩ Coloured sectors show recommended areas of settings: - Indicates alarm trip zone - Indicates warning trip zone - Indicates healthy zone Output table (example for...

Open the catalog to page 2
KCM165K - 3

STANDBY INSULATION GUARD (MEGGER) FOR NON-GROUNDED SYSTEMS KCM165K Reset / Parallelling Disable Function DC Aux. Supply (Optional) NOTE: See below for correct connection Main Supply KCM165K has a built-in disable function (available only when DCAux. Supply is applied). 1 2 When connecting two or more IT-networks together only one unit can be active, the other(s) must be disabled. Motor breaker R3 Cable with RJ12 plug Note: Use a N.C. auxiliary contact on the motor breaker to connect KCM165K for standby mode When unit is disabled the power LED will flash every 2 seconds to indicate that unit...

Open the catalog to page 3

All Meagacon AS catalogs and technical brochures

  1. MT-VA

    2 Pages

  2. MT-VF

    2 Pages

  3. MT-AW-R

    3 Pages

  4. MT-FP

    2 Pages

  5. MT-FW/R

    3 Pages

  6. MEVx Series

    1 Pages

  7. MCVBx Series

    1 Pages

  8. KCT3x Series

    1 Pages

  9. KPM465x

    3 Pages

  10. KPM26x

    4 Pages

  11. KPM163FQ

    2 Pages

  12. KPM161FQ

    2 Pages

  13. KPM 16xM

    3 Pages

  14. K P M 1 6 x

    5 Pages